Stent Graft Change Detection After Endovascular Abdominal Aortic Aneurysm Repair

被引:0
作者
Maiora, Josu [1 ]
Garcia, Guillermo [2 ]
Tapia, Arantxa [2 ]
Macia, Ivan [3 ]
Haitz Legarreta, Jon [3 ]
Paloc, Celine [3 ]
Grana, Manuel [4 ]
de Blas, Mariano [5 ]
机构
[1] Univ Basque Country, Tech Univ Sch, Elect & Telecommun Dept, Donostia San Sebastian, Spain
[2] Univ Basque Country, Techn Univ Sch, Engn Syst & Automat Dept, Donostia San Sebastian, Spain
[3] VICOMTech, Biomed Appl Dept, Donostia San Sebastian, Spain
[4] Univ Basque Country, Fac Comp Sci, Comp Intelligence Grp, Donostia San Sebastian, Spain
[5] Donostia Hosp, Intervent Radiol Serv, Donostia San Sebastian, Spain
来源
INTELLIGENT DATA ENGINEERING AND AUTOMATED LEARNING, PROCEEDINGS | 2009年 / 5788卷
关键词
image processing; aneurysm; endovascular; registration;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The use of the endovascular prostheses in Abdominal Aortic Aneurysm (EVAR) has proven to be an effective technique to reduce the pressure and rupture risk of aneurysm. Nevertheless. in a long term perspective different complications such as prostheses displacement or leaks inside the aneurysm sac (endoleaks) could appear causing a pressure elevation and increasing the danger of rupture consequently. At present computed tomographic angiography (CTA) is the most commonly used examination for imaging surveillance for stent graft monitoring. However, endoleak complications can not always be detected by visual inspection on CTA scans. The purpose of this work was to study the application of image registration techniques to the detection of changes in the stent graft. Previously we segment the lumen using semi-automatic methods.
引用
收藏
页码:656 / +
页数:3
相关论文
共 12 条
[1]   Screening for abdominal aortic aneurysm: Recommendation statement [J].
Calonge, N ;
Allan, JD ;
Berg, AO ;
Frame, PS ;
Gordis, L ;
Gregory, KD ;
Harris, R ;
Johnson, MS ;
Klein, JD ;
Loveland-Cherry, C ;
Moyer, VA ;
Ockene, JK ;
Petitti, DB ;
Siu, AL ;
Teutsch, SM ;
Yawn, BP .
ANNALS OF INTERNAL MEDICINE, 2005, 142 (03) :198-202
[2]  
CRONENWETT JL, 2000, VASCULAR SURG, P1246
[3]   Abdominal aortic aneurysm sac shrinkage after endovascular aneurysm repair: Correlation with chronic sac pressure measurement [J].
Ellozy, SH ;
Carroccio, A ;
Lookstein, RA ;
Jacobs, TS ;
Addis, MD ;
Teodorescu, VJ ;
Marin, ML .
JOURNAL OF VASCULAR SURGERY, 2006, 43 (01) :2-6
[4]  
Ibanez L., 2003, ITK SOFTWARE GUIDE
[5]   Spatio-temporal changes and migration of stent grafts after endovascular aortic aneurysm repair [J].
Mattes, J ;
Steingruber, I ;
Netzer, M ;
Fritscher, K ;
Kopf, H ;
Jaschke, W ;
Schubert, R .
CARS 2005: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2005, 1281 :393-397
[6]  
MATTES J, 2006, P SPIE 1, V6144
[7]   Time-series analysis of MRI intensity patterns in multiple sclerosis [J].
Meier, DS ;
Guttmann, CRG .
NEUROIMAGE, 2003, 20 (02) :1193-1209
[8]  
Parodi J C, 1991, Ann Vasc Surg, V5, P491, DOI 10.1007/BF02015271
[9]  
Rodin M B., 2003, Hypertension
[10]   Intra-aneurysm pressure measurements in successfully excluded abdominal aortic aneurysm after endovascular repair [J].
Sonesson, B ;
Dias, N ;
Malina, M ;
Olofsson, P ;
Griffin, D ;
Lindblad, B ;
Ivancev, K .