The clinical value of 3-dimensional saline infusion sonography in addition to 2-dimensional saline infusion sonography in women with abnormal uterine bleeding -: Work in progress

被引:31
作者
de Kroon, CD [1 ]
Louwé, LA [1 ]
Trimbos, JB [1 ]
Jansen, FW [1 ]
机构
[1] Leiden Univ, Ctr Med, Dept Gynecol, NL-2300 RC Leiden, Netherlands
关键词
intrauterine abnormalities; reliability; saline infusion sonography; 3-dimensional saline infusion sonography; 3-dimensional sonography; validation;
D O I
10.7863/jum.2004.23.11.1433
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. To evaluate the clinical relevance of 3-dimensional saline infusion sonography (3D-SIS) in addition to conventional SIS in women with abnormal uterine bleeding suspected of having intrauterine abnormalities. Methods. All women suspected of having intrauterine abnormalities were eligible. Before 3D-SIS, conventional SIS was performed. The results of these techniques were compared with the "combined method reference standard" (hysteroscopy, endometrial sampling, and clinical follow-up in cases with normal SIS findings). Diagnostic characteristics (with 95% confidence intervals [CIs]) of 3D-SIS and SIS were calculated as well as their respective accuracy in evaluating the histologic nature, the intrauterine extension, and the location of intrauterine abnormalities. Moreover, the reliability (kappa value) and clinical relevance of 3D-SIS were assessed. Results. A total of 49 women were included, and 4 women were excluded. The positive predictive values of 3D-SIS and SIS were, respectively, 1.00 and 0.86 (95% CI, 0.72-0.99; P = . 15), and the diagnostic accuracy values were 0.98 (95% CI, 0.94-1.0) and 0.91 (95% CI, 0.83-0.99; P = .08). Saline infusion sonography and 3D-SIS were equally accurate in evaluating the histologic nature, intrauterine extent, and location of intrauterine abnormalities (respective K values: 0.85 versus 0.93; P = .88; 0.83 versus 0.83; and 0.77 versus 0.80; P = .81). The reliability of 3D-SIS was good: intraobserver and interobserver agreement (kappa) were 0.78 and 0.72. Three women (6.7%) had the benefit of additional 3D-SIS: in these women, SIS wrongly led to a diagnosis of intrauterine abnormalities (P = .08). Conclusions. Three-dimensional saline infusion sonography is valid and reliable in women suspected of having intrauterine abnormalities and may indeed have relevant clinical value in addition to conventional SIS.
引用
收藏
页码:1433 / 1440
页数:8
相关论文
共 36 条
[1]   Contrast sonography for uterine cavity assessment: A comparison of conventional two-dimensional with three-dimensional transvaginal ultrasound a pilot study [J].
Ayida, G ;
Kennedy, S ;
Barlow, D ;
Chamberlain, P .
FERTILITY AND STERILITY, 1996, 66 (05) :848-850
[2]  
Bega G, 2001, J ULTRAS MED, V20, P391
[3]   BIASES IN THE ASSESSMENT OF DIAGNOSTIC-TESTS [J].
BEGG, CB .
STATISTICS IN MEDICINE, 1987, 6 (04) :411-423
[4]   Three-dimensional hysterosonography for the study of endometrial tumors: Comparison with conventional transvaginal sonography, hysterosalpingography, and hysteroscopy [J].
BonillaMusoles, F ;
Raga, F ;
Osborne, NG ;
Blanes, J ;
Coelho, F .
GYNECOLOGIC ONCOLOGY, 1997, 65 (02) :245-252
[5]   The STARD statement for reporting studies of diagnostic accuracy: Explanation and elaboration [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Moher, D ;
Rennie, D ;
de Vet, HCW ;
Lijmer, JG .
CLINICAL CHEMISTRY, 2003, 49 (01) :7-18
[6]   Cost-effectiveness of saline-assisted hysterosonography and office hysteroscopy in the evaluation of postmenopausal bleeding: A decision analysis [J].
Carlos, RC ;
Bree, RL ;
Abrahamse, PH ;
Fendrick, AM .
ACADEMIC RADIOLOGY, 2001, 8 (09) :835-844
[7]   Evaluation of a clinical test. II: Assessment of validity [J].
Chien, PFW ;
Khan, KS .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2001, 108 (06) :568-572
[8]  
CININELLI E, 1995, OBSTET GYNECOL, V85, P42
[9]   Saline contrast hysterosonography in abnormal uterine bleeding: a systematic review and meta-analysis [J].
de Kroon, CD ;
de Bock, GH ;
Dieben, SWM ;
Jansen, FW .
BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2003, 110 (10) :938-947
[10]   Technology assessment of saline contrast hysterosonography [J].
de Kroon, CD ;
Jansen, FW ;
Louwé, LA ;
Dieben, SWM ;
van Houwelingen, HC ;
Trimbos, JB .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2003, 188 (04) :945-949