ICP-MS determination of trace elements in fish

被引:0
|
作者
Chamberlain, I [1 ]
Adams, K [1 ]
Le, S [1 ]
机构
[1] US EPA, Manchester Environm Lab, Port Orchard, WA 98366 USA
关键词
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In 1996, USEPA Region 10 began a study of contaminants in fish collected from the Columbia River Basin. The study included analysis of a suite of parameters including total recoverable metals. Part of this project entailed the investigation of several options for the digestion and analysis of fish tissue samples. This article provides a comparison of the Inductively Coupled Plasma Mass Spectrometry (ICP-MS) determination of 17 elements in fish tissue with and without the addition of hydrochloric acid (HCl) in the digestion. Omitting the addition of HCl, a reagent required in EPA Method 200.3 (1) and the basis for the digestion procedure reduced the isobaric molecular interferences in a difficult, carbon-rich matrix. This allowed determination of 17 elements of interest simultaneously by ICP-MS, enhancing sample throughput without compromising sensitivity, data quality, or accuracy. Sample preparation protocols are included.
引用
收藏
页码:118 / 122
页数:5
相关论文
共 50 条
  • [21] Determination of selenium in the commercially bottled drinking water by ICP-MS - Determination of trace elements in environmental samples by ICP-MS .4.
    Naohara, J
    Yamashita, E
    JOURNAL OF THE JAPANESE SOCIETY FOR FOOD SCIENCE AND TECHNOLOGY-NIPPON SHOKUHIN KAGAKU KOGAKU KAISHI, 1996, 43 (10): : 1133 - 1137
  • [22] Optimization of Sample Preparation in the Determination of Minerals and Trace Elements in Honey by ICP-MS
    Leme, Ana B. P.
    Bianchi, Silmara R.
    Carneiro, Renato L.
    Nogueira, Ana R. A.
    FOOD ANALYTICAL METHODS, 2014, 7 (05) : 1009 - 1015
  • [23] Comparison of NAA and ICP-MS for the determination of major and trace elements in environmental sample
    Tsukada, H
    Takeda, A
    Hasegawa, H
    Ueda, S
    Iyogi, T
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 263 (03) : 773 - 778
  • [24] UTILIZATION OF ICP-AES AND ICP-MS FOR THE DETERMINATION OF TRACE-ELEMENTS IN COMPLEX MATRICES
    FRICKE, FL
    SATZGER, RD
    WOLNIK, KA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 181 - ANYL
  • [25] Comparison of ICP-OES and ICP-MS and their application to the determination of trace elements in fertilizers.
    Wallace, G
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 222 : U65 - U65
  • [26] Determination of trace elements in small amounts of environmental samples by ICP-MS: A review
    Becker, JS
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2002, 47 (04): : 98 - 108
  • [27] Determination of major and trace elements in Japanese rock reference samples by ICP-MS
    Yoshida, S
    Muramatsu, Y
    Tagami, K
    Uchida, S
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1996, 63 (03) : 195 - 206
  • [28] Comparison of NAA and ICP-MS for the determination of major and trace elements in environmental sample
    H. Tsukada
    A. Takeda
    H. Hasegawa
    S. Ueda
    T. Iyogi
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 263 : 773 - 778
  • [29] Determination of Trace Elements and Heavy Metals in Coconut Meat Simultaneously by ICP-MS
    Zhang, Yanbei
    Rui, Yukui
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (09) : 5105 - 5106
  • [30] Trace elements determination in edible seaweeds by an optimized and validated ICP-MS method
    Rodenas de la Rocha, S.
    Sanchez-Muniz, F. J.
    Gomez-Juaristi, M.
    Larrea Marin, M. T.
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2009, 22 (04) : 330 - 336