In Vitro Evaluation of MR Imaging Issues at 3T for Aneurysm Clips Made from MP35N: Findings and Information Applied to 155 Additional Aneurysm Clips

被引:39
作者
Shellock, F. G. [1 ,2 ]
Valencerina, S. [3 ]
机构
[1] Inst Magnet Resonance Safety Educ & Res, Los Angeles, CA 90045 USA
[2] Univ So Calif, Keck Sch Med, Los Angeles, CA 90033 USA
[3] Univ So Calif, Univ Hosp, Los Angeles, CA 90033 USA
关键词
MAGNETIC-FIELD INTERACTIONS; BIOMEDICAL IMPLANTS; ARTIFACTS; DEVICES; SAFETY; 3-TESLA; SYSTEM;
D O I
10.3174/ajnr.A1918
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Aneurysm clips need to be tested at 3T to characterize MR imaging concerns, including magnetic field interactions, MR imaging-related heating, and artifacts. Therefore, we evaluated these risks for aneurysm clips. MATERIALS AND METHODS: Three different MP35N aneurysm clips (Codman Slim-Line Aneurysm Clip, straight, blade length 25-mm; Codman Slim-Line Aneurysm Clip Graft, 5-mm diameter x 5-mm width; Codman Slim-Line Aneurysm Clip, reinforcing 30 angle, 6-mm x 18-mm) that represented the largest mass for 155 additional clips made from MP35N were tested. The clips were evaluated at 3T for magnetic field interactions, heating, and artifacts. We studied MR imaging related heating, placing the clip in a gelled-saline-filled phantom with MR imaging performed by using a transmit/receive radio-frequency body coil at a whole-body average SAR of 3 W/kg for 15 minutes. Artifacts were characterized by using T1-SE and GRE pulse sequences. RESULTS: Each aneurysm clip showed relatively minor magnetic field interactions, which would not cause movement in situ. Heating was not excessive (highest temperature change, <1.8 degrees C). Artifacts may create problems if the area of interest is in the same area or close to the aneurysm clip. CONCLUSIONS: The results of this investigation demonstrated that it would be acceptable lie, "MR conditional" using current terminology) for patients with these aneurysm clips to undergo MR imaging at <= 3T. Notably, on the basis of the sizes of the clips that underwent testing, these findings pertain to 155 additional aneurysm clips made from the same material.
引用
收藏
页码:615 / 619
页数:5
相关论文
共 33 条
[1]   Power deposition inside a phantom for testing of MRI heating [J].
Amjad, A ;
Kamondetdacha, R ;
Kildishev, AV ;
Park, SM ;
Nyenhuis, JA .
IEEE TRANSACTIONS ON MAGNETICS, 2005, 41 (10) :4185-4187
[2]  
[Anonymous], 2005, ANN BOOK ASTM STAND, V04.13
[3]  
*ASTM, 1576, ANN BOOK ASTM STAND
[4]  
BECKER RL, 1988, AM J NEURORADIOL, V9, P885
[5]   Treatment of unruptured intracranial aneurysms: Surgery, coiling, or nothing? [J].
Burns, Joseph D. ;
Brown, Robert D., Jr. .
CURRENT NEUROLOGY AND NEUROSCIENCE REPORTS, 2009, 9 (01) :6-12
[6]   Investigation of the factors responsible for burns during MRI [J].
Dempsey, MF ;
Condon, B ;
Hadley, DM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) :627-631
[7]  
Houdas Y., 1982, PRINCIPLES HEAT TRAN
[8]   NEED FOR CAUTION DURING MR-IMAGING OF PATIENTS WITH ANEURYSM CLIPS [J].
JOHNSON, GC .
RADIOLOGY, 1993, 188 (01) :287-288
[9]   Aneurysm clip testing for ferromagnetic properties: Clip variability issues [J].
Kanal, E ;
Shellock, FG ;
Lewin, JS .
RADIOLOGY, 1996, 200 (02) :576-578
[10]   MR-IMAGING OF PATIENTS WITH INTRACRANIAL ANEURYSM CLIPS [J].
KANAL, E ;
SHELLOCK, FG .
RADIOLOGY, 1993, 187 (03) :612-614