Assessment of coronary in-stent restenosis: value of subtraction coronary computed tomography angiography

被引:27
作者
Amanuma, Makoto [1 ]
Kondo, Taskeshi [2 ]
Sano, Tomonari [3 ]
Takayanagi, Tomoya [3 ]
Matsutani, Hideyuki [3 ]
Sekine, Takako [3 ]
Arai, Takehiro [3 ]
Morita, Hitomi [3 ]
Ishizaka, Kazumasa [3 ]
Arakita, Kazumasa [4 ]
Iwasa, Akiko [5 ]
Takase, Shinichi [6 ]
机构
[1] Takase Clin, Dept Radiol, 885-2 Minami Orui, Takasaki, Gunma 3700036, Japan
[2] Jukokai Cent Hosp, Dept Cardiol, Miyoshi, Japan
[3] Takase Clin, Dept Radiat Technol, Takasaki, Gunma, Japan
[4] Toshiba Med Corp, Clin Applicat Res Ctr, Otawara, Japan
[5] Toshiba Med Corp, CT Sales Dept, Applicat Grp, Otawara, Japan
[6] Takase Clin, Dept Cardiol, Takasaki, Gunma, Japan
关键词
Computed tomography; Metallic stent; Instent restenosis; Coronary CTA; Subtraction; CT ANGIOGRAPHY; ITERATIVE RECONSTRUCTION; IMAGE QUALITY; PERFORMANCE;
D O I
10.1007/s10554-015-0826-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In conventional coronary computed tomography angiography (CCTA), metal artifacts are frequently observed where stents are located, making it difficult to evaluate in-stent restenosis. This study was conducted to investigate whether subtraction CCTA can improve diagnostic accuracy in the evaluation of in-stent restenosis. Subtraction CCTA was performed using 320-row CT in 398 patients with previously placed stents who were able to hold their breath for 25 s and in whom mid-diastolic prospective one-beat scanning was possible. Among these patients, 126 patients (94 men and 32 women, age 74 +/- A 8 years) with 370 stents who also underwent invasive coronary angiography (ICA) were selected as the subjects of this study. With ICA findings considered the gold standard, conventional CCTA was compared against subtraction CCTA to determine whether subtraction can improve diagnostic accuracy in the evaluation of in-stent restenosis. When non-assessable stents were considered to be stenotic, the diagnostic accuracy in the evaluation of in-stent restenosis was 62.7 % for conventional CCTA and 89.5 % for subtraction CCTA. When the non-assessable stents were considered to be non-stenotic the diagnostic accuracy was 90.3 % for conventional CCTA and 94.31 % for subtraction CCTA. When subtraction CCTA was used to evaluate only the 138 stents that were judged to be non-assessable by conventional CCTA, 116 of these stents were judged to be assessable, and the findings for 109 of them agreed with those obtained by ICA. Even for stents with an internal diameter of 2.5-3 mm, the lumen can be evaluated in more than 80 % of patients. Subtraction CCTA provides significantly higher diagnostic accuracy than conventional CCTA in the evaluation of in-stent restenosis.
引用
收藏
页码:661 / 670
页数:10
相关论文
共 29 条
[1]  
Abbara Suhny, 2009, J Cardiovasc Comput Tomogr, V3, P190, DOI 10.1016/j.jcct.2009.03.004
[2]   Influence of coronary calcification on the diagnostic accuracy of 64-slice computed tomography coronary angiography: a systematic review and meta-analysis [J].
Abdulla, Jawdat ;
Pedersen, Kasper S. ;
Budoff, Matthew ;
Kofoed, Klaus F. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04) :943-953
[3]   Subtraction coronary computed tomography in patients with severe calcification [J].
Amanuma, Makoto ;
Kondo, Takeshi ;
Sano, Tomonari ;
Sekine, Takako ;
Takayanagi, Tomoya ;
Matsutani, Hideyuki ;
Arai, Takehiro ;
Morita, Hitomi ;
Ishizaka, Kazumasa ;
Arakita, Kazumasa ;
Iwasa, Akiko ;
Takase, Shinichi .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (08) :1635-1642
[4]  
[Anonymous], 2010, J CARDIOVASC COMPUT, DOI [10.1016/j.jcct.2010.11.001, DOI 10.1016/J.JCCT.2010.11.001.MULTIS0CIETAL]
[5]  
Austen W G, 1975, Circulation, V51, P5
[6]   Coronary stent patency: Dual-energy multidetector CT assessment in a pilot study with anthropomorphic phantom [J].
Boll, Daniel T. ;
Merkle, Elmar M. ;
Paulson, Erik K. ;
Fleiter, Thorsten R. .
RADIOLOGY, 2008, 247 (03) :687-695
[7]   Radiation Dose from Single-Heartbeat Coronary CT Angiography Performed with a 320-Detector Row Volume Scanner [J].
Einstein, Andrew J. ;
Elliston, Carl D. ;
Arai, Andrew E. ;
Chen, Marcus Y. ;
Mather, Richard ;
Pearson, Gregory D. N. ;
DeLaPaz, Robert L. ;
Nickoloff, Edward ;
Dutta, Ajoy ;
Brenner, David J. .
RADIOLOGY, 2010, 254 (03) :698-706
[8]  
Fuchs A, 2015, J CARDIOVASC COMPUT, DOI [10.1016/j.jcct2015.03.016, DOI 10.1016/J.JCCT2015.03.016]
[9]   Image Quality and Radiation Dose Stratified by Patient Heart Rate for Coronary 64-and 320-MDCT Angiography [J].
Fujimoto, Shinichiro ;
Matsutani, Hideyuki ;
Kondo, Takeshi ;
Sano, Tomonari ;
Kumamaru, Kanako ;
Takase, Shinichi ;
Rybicki, Frank J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (04) :765-770
[10]   Automatic exposure control at single- and dual-heartbeat CTCA on a 320-MDCT volume scanner: Effect of heart rate, exposure phase window setting, and reconstruction algorithm [J].
Funama, Yoshinori ;
Utsunomiya, Daisuke ;
Taguchi, Katsuyuki ;
Oda, Seitaro ;
Shimonobo, Toshiaki ;
Yamashita, Yasuyuki .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (03) :385-390