Development and testing of a new self-locking intramedullary nail system: testing of handling aspects and mechanical properties

被引:19
作者
Knothe, U [1 ]
Tate, MLK [1 ]
Klaue, K [1 ]
Perren, SM [1 ]
机构
[1] Univ Hosp Bern, Dept Orthopaed Surg, CH-3010 Bern, Switzerland
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2000年 / 31卷 / 08期
关键词
D O I
10.1016/S0020-1383(00)00064-4
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
A distal interlocking system has been developed which is easy to use, carries out an aligning effect on the distal fracture fragment, reduces the exposure to radiation for the surgeon and the patient, and allows for a decrease in operating time. The goal of this study was to develop and test the handling and mechanical properties of two prototype nails in comparison to a conventional interlocking nail concept (Unreamed Femoral Nail(R) system). It was shown that the prototype designs represent an improvement over this system. Both designs were easy to use. The prototype with the asymmetrically offset interlocking bolts exhibited an exemplary aligning effect on the distal fracture fragment. Both designs showed mechanical stability comparable or superior to that of the standard contralateral control in four-point-bending and axial compression. Given the handling advantages afforded by the new self-locking intramedullary implant system, it would be expected that use of this system would reduce exposure to radiation for the surgeon as well as the patient and allow for a decrease in operating time. This new development may be of particular interest for clinics without access to fluoroscopes in the operating theatre (e.g. in the Third World). (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:617 / 626
页数:10
相关论文
共 26 条
[1]   PAIRWISE STRENGTH RELATIONSHIPS OF CORTICAL AND CANCELLOUS BONE IN HUMAN FEMUR - AN AUTOPSY STUDY [J].
ALHO, A ;
STROMSOE, K ;
HOISETH, A .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1995, 114 (04) :211-214
[2]  
ALLEN WC, 1968, CLIN ORTHOP RELAT R, P13
[3]  
BANKSTON AB, 1992, CLIN ORTHOP RELAT R, P277
[4]  
BECHTOLD JE, 1989, ASTM STP, V1008, P60
[5]  
BORNER M, 1984, HEFTE UNFALLHEILKD, V182, P387
[6]  
BUCHOLZ RW, 1987, J BONE JOINT SURG AM, V69A, P1391
[7]   A BIOMECHANICAL COMPARISON OF INTRAMEDULLARY NAILING SYSTEMS FOR THE HUMERUS [J].
DALTON, JE ;
SALKELD, SL ;
SATTERWHITE, YE ;
COOK, SD .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1993, 7 (04) :367-374
[8]   THE USE OF ONE COMPARED WITH 2 DISTAL SCREWS IN THE TREATMENT OF FEMORAL-SHAFT FRACTURES WITH INTERLOCKING INTRAMEDULLARY NAILING - A CLINICAL AND BIOMECHANICAL ANALYSIS [J].
HAJEK, PD ;
BICKNELL, HR ;
BRONSON, WE ;
ALBRIGHT, JA ;
SAHA, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (04) :519-525
[9]   A SIMPLE JIG TO EASE THE INSERTION OF DISTAL SCREWS IN INTRAMEDULLARY LOCKING NAILS [J].
HASHEMINEJAD, A ;
GARLICK, N ;
GODDARD, NJ .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1994, 25 (06) :407-408
[10]  
HOLISTIEN S, 1996, OSTEOPOROSIS INT, V3, P196