Right or wrong sample received for coagulation testing? Tentative algorithms for detection of an incorrect type of sample

被引:30
作者
Lippi, G. [1 ]
Salvagno, G. L. [1 ]
Adcock, D. M. [2 ]
Gelati, M. [1 ]
Guidi, G. C. [1 ]
Favaloro, E. J. [3 ]
机构
[1] Univ Verona, Sez Chim Clin, Dipartimento Sci Morfol Biomed, I-37134 Verona, Italy
[2] Esoterix Coagulat, Englewood, CO USA
[3] Westmead Hosp, Dept Haematol, ICPMR, Westmead, NSW 2145, Australia
关键词
Pre-analytical variability; coagulation testing; citrate; ethylene diamine tetraacetic acid; plasma; serum; DIAGNOSTIC HEMOSTASIS LABORATORIES; FACTOR INHIBITORS; ANTICOAGULANT; RECOGNITION;
D O I
10.1111/j.1751-553X.2009.01142.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
P>Inappropriate blood collection potentially comprises the major pre-analytical problem for coagulation testing. Inappropriate samples are most difficult to detect when received as secondary aliquots, common for referred tests. This study aimed to identify a simple, quick and inexpensive process to help laboratories distinguish the type of sample, should there be suspicion of inappropriate collection. Samples from 15 patients [selected on the basis that four different primary tubes were available: serum, citrated plasma, ethylene diamine tetraacetic acid (EDTA) plasma, lithium-heparin plasma], were tested for common electrolytes that might substantially differ according to the type of sample. In citrated plasma, potassium, chloride, calcium and magnesium were significantly decreased compared with serum and lithium-heparin plasma, while sodium was markedly increased. In EDTA plasma, sodium and chloride were significantly decreased compared with both serum and lithium-heparin plasma, potassium was always > 14 mmol/l, whereas magnesium and calcium were virtually undetectable. These data allowed development of two algorithms for differential identification of citrated plasma vs. other samples with 100% sensitivity and specificity, the former based on the sequential measurement of potassium, calcium and sodium, the latter on potassium and sodium. These simple assays can supplement classical coagulation test methods to identify most inappropriate blood collections and validate sample rejection.
引用
收藏
页码:132 / 137
页数:6
相关论文
共 14 条
  • [1] The role of ethylenedimine tetraacetic acid (EDTA) as in vitro anticoagulant for diagnostic purposes
    Banfi, Giuseppe
    Salvagno, Gian Luca
    Lippi, Giuseppe
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (05) : 565 - 576
  • [2] Errors in a stat laboratory: Types and frequencies 10 years later
    Carraro, Paolo
    Plebani, Mario
    [J]. CLINICAL CHEMISTRY, 2007, 53 (07) : 1338 - 1342
  • [3] RECOMMENDATIONS OF THE INTERNATIONAL COUNCIL FOR STANDARDIZATION IN HEMATOLOGY FOR ETHYLENEDIAMINETETRAACETIC ACID ANTICOAGULATION OF BLOOD FOR BLOOD-CELL COUNTING AND SIZING
    ENGLAND, JM
    ROWAN, RM
    VANASSENDELFT, OW
    BULL, BS
    COULTER, W
    FUJIMOTO, K
    GRONER, W
    RICHARDSONJONES, A
    KLEE, G
    KOEPKE, JA
    LEWIS, SM
    MCLAREN, CE
    SHINTON, NK
    TATSUMI, N
    VERWILGHEN, RL
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 100 (04) : 371 - 372
  • [4] An international survey of current practice in the laboratory assessment of anticoagulant therapy with heparin
    Favaloro, EJ
    Bonar, R
    Sioufi, J
    Wheeler, M
    Low, J
    Aboud, M
    Lloyd, J
    Street, A
    Marsden, K
    [J]. PATHOLOGY, 2005, 37 (03) : 234 - 238
  • [5] FAVALORO EJ, 1995, AM J CLIN PATHOL, V104, P264
  • [6] Mis-identification of factor inhibitors by diagnostic haemostasis laboratories: recognition of pitfalls and elucidation of strategies. A follow up to a large multicentre evaluation
    Favaloro, Emmanuel J.
    Bonar, Roslyn
    Duncan, Elizabeth
    Earl, Gail
    Low, Joyce
    Aboud, Margaret
    Just, Sarah
    Sioufi, John
    Street, Alison
    Marsden, Katherine
    [J]. PATHOLOGY, 2007, 39 (05) : 504 - 511
  • [7] Identification of factor inhibitors by diagnostic haemostasis laboratories - A large multi-centre evaluation
    Favaloro, Emmanuel J.
    Bonar, Roslyn
    Duncan, Elizabeth
    Earl, Gail
    Low, Joyce
    Aboud, Margaret
    Just, Sarah
    Sioufi, John
    Street, Alison
    Marsden, Katherine
    [J]. THROMBOSIS AND HAEMOSTASIS, 2006, 96 (01) : 73 - 78
  • [8] Preanalytical and Postanalytical Variables: The Leading Causes of Diagnostic Error in Hemostasis?
    Favaloro, Emmanuel J.
    Lippi, Giuseppe
    Adcock, Dorothy M.
    [J]. SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2008, 34 (07) : 612 - 634
  • [9] Gidenne S, 2003, ANN BIOL CLIN-PARIS, V61, P393
  • [10] Laboratory medicine in the 2000s: programmed death or rebirth?
    Guidi, Gian Cesare
    Lippi, Giuseppe
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (08) : 913 - 917