共 33 条
A novel fatty-acid-based in-tube dispersive liquid-liquid microextraction technique for the rapid determination of nonylphenol and 4-tert-octylphenol in aqueous samples using high-performance liquid chromatography-ultraviolet detection
被引:75
作者:
Shih, Hou-Kuang
[1
]
Shu, Ting-Yun
[1
]
Ponnusamy, Vinoth Kumar
[1
,2
]
Jen, Jen-Fon
[1
]
机构:
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
[2] Chi Mei Entech Co & Ltd, CME Food Testing Lab, Taichung 408, Taiwan
关键词:
Fatty acid;
In-tube dispersive liquid-liquid microextraction;
High-performance liquid chromatography;
Alkylphenols;
Aqueous sample;
CLOUD-POINT EXTRACTION;
ENVIRONMENTAL WATER SAMPLES;
PHASE MICROEXTRACTION;
BISPHENOL-A;
EMULSIFICATION-MICROEXTRACTION;
GAS-CHROMATOGRAPHY;
AROMATIC-AMINES;
ORGANIC-SOLVENT;
SINGLE-DROP;
SURFACTANT;
D O I:
10.1016/j.aca.2014.11.021
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
In this study, a novel fatty-acid-based in-tube dispersive liquid-liquid microextraction (FA-IT-DLLME) technique is proposed for the first time and is developed as a simple, rapid and eco-friendly sample extraction method for the determination of alkylphenols in aqueous samples using high-performance liquid chromatography-ultraviolet detection (HPLC-UV). In this extraction method, medium-chain saturated fatty acids were investigated as a pH-dependent phase because they acted as either anionic surfactants or neutral extraction solvents based on the acid-base reaction caused solely by the adjustment of the pH of the solution. A specially designed home-made glass extraction tube with a built-in scaled capillary tube was utilized as the phase-separation device for the FA-IT-DLLME to collect and measure the separated extractant phase for analysis. Nonylphenol (NP) and 4-tert-octylphenol (4-tOP) were chosen as model analytes. The parameters influencing the FA-IT-DLLME were thoroughly investigated and optimized. Under the optimal conditions, the detector responses of NP and 4-tOP were linear in the concentration ranges of 5-4000 mu g L-1, with correlation coefficients of 0.9990 and 0.9996 for NP and 4-tOP, respectively. The limits of detection based on a signal-to-noise ratio of 3 were 0.7 and 0.5 mu g L-1, and the enrichment factors were 195 and 143 for NP and 4-tOP, respectively. The applicability of the developed method was demonstrated for the analysis of alkylphenols in environmental wastewater samples, and the recoveries ranged from 92.9 to 107.1%. The extraction process required less than 4 min and utilized only acids, alkalis, and fatty acids to achieve the extraction. The results demonstrated that the presented FA-IT-DLLME approach is highly cost-effective, simple, rapid and environmentally friendly in its sample preparation. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:70 / 77
页数:8
相关论文