Boiling heat transfer in small rectangular channels at low Reynolds number and mass flux

被引:10
作者
Wang, Sheng [1 ]
Bi, Xiaotao [2 ]
Wang, Shudong [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Dalian Natl Lab Clean Energy DNL, 457 Zhongshan Rd, Dalian 116023, Peoples R China
[2] Univ British Columbia, Dept Chem & Biol Engn, 2216 Main Mall, Vancouver, BC V6T 1Z4, Canada
基金
中国国家自然科学基金;
关键词
Flow boiling; Heat transfer; Mini-channel; Compact heat exchangers; GENERAL CORRELATION; SILICON MICROCHANNELS; TRANSFER COEFFICIENT; PRESSURE-DROP; FLOW; INSTABILITIES; WATER; PREDICTION; CONVECTION; TUBES;
D O I
10.1016/j.expthermflusci.2016.04.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
Boiling heat transfer experiments were performed in a small rectangular channel (hydraulic diameter, De = 3.0 mm) with water and methanol. The channel size represents the tube configurations in plate fin heat exchangers, which are commonly used for generating hydrogen from hydrogen-rich liquid fuels. The tested mass flux ranged from 6.59 to 21.97 kg m(-2) s, heat flux from 13.3 to 30.1 kW m(-2) and inlet temperatures from ambient to 80 degrees C. Tests were carried out at atmospheric pressure. Local heat transfer coefficients were determined experimentally as a function of vapor quantity along the length of the test section. Insights into heat transfer mechanisms in small channels are presented over a range of Reynolds number from 38 to 263. Experimental results and comparisons with state-of-the-art predictive correlations are presented. The Chen correlation was found to be most suitable for predictions of water boiling heat transfer under the recommended application range for minichannels. For methanol, the Shah correlation was more sound over the range with Re larger than 50, while the Gungor-Winterton equation was more accurate when Re was smaller than 50. In addition, flow boiling instability in minichannels was detected when the flow was dominated by subcooled boiling. However, the periodic oscillations of temperature and pressure disappeared when the heat transfer became dominated by saturated boiling. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:234 / 245
页数:12
相关论文
共 41 条
[1]  
Agarwal G., 2010, C THERM HYDR DEV FLO, P1342
[2]   Liquid flow friction factor and heat transfer coefficient in small channels: an experimental investigation [J].
Agostini, B ;
Watel, B ;
Bontemps, A ;
Thonon, B .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2004, 28 (2-3) :97-103
[3]   Flow boiling heat transfer of Freon R11 and HCFC123 in narrow passages [J].
Bao, ZY ;
Fletcher, DF ;
Haynes, BS .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2000, 43 (18) :3347-3358
[4]   Hydrodynamics and heat transfer during flow boiling instabilities in a single microchannel [J].
Barber, Jacqueline ;
Sefiane, Khellil ;
Brutin, David ;
Tadrist, Lounes .
APPLIED THERMAL ENGINEERING, 2009, 29 (07) :1299-1308
[5]   Optimization of conduits' shape in micro heat exchangers [J].
Bau, HH .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1998, 41 (18) :2717-2723
[6]   Convection heat transfer from discrete heat sources in a liquid cooled rectangular channel [J].
Bhowmik, H ;
Tso, CP ;
Tou, KW ;
Tan, FL .
APPLIED THERMAL ENGINEERING, 2005, 25 (16) :2532-2542
[7]   Experimental study of unsteady convective boiling in heated minichannels [J].
Brutin, D ;
Topin, F ;
Tadrist, L .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (16) :2957-2965
[8]   CORRELATION FOR BOILING HEAT TRANSFER TO SATURATED FLUIDS IN CONVECTIVE FLOW [J].
CHEN, JC .
INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1966, 5 (03) :322-&
[9]  
Cooper M. G., 1984, First U.K. National Conference on Heat Transfer, P785
[10]   A new correlation of flow boiling heat transfer coefficients for carbon dioxide [J].
Fang, Xiande .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 64 :802-807