Column restraint in post-tensioned self-centering moment frames

被引:29
作者
Chou, Chung-Che [1 ,2 ]
Chen, Jun-Hen [3 ]
机构
[1] Natl Taiwan Univ, Dept Civil Engn, Taipei 10764, Taiwan
[2] Natl Ctr Res Earthquake Engn, Taipei, Taiwan
[3] Natl Chiao Tung Univ, Dept Civil Engn, Hsinchu, Taiwan
关键词
post-tensioned self-centering frame; frame expansion; cyclic frame test; cyclic analysis; column deformation compatibility; STEEL CONNECTIONS; PERFORMANCE; BEHAVIOR; DESIGN;
D O I
10.1002/eqe.972
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Gaps between beam-to-column interfaces in a post-tensioned (PT) self-centering frame with more than one column are constrained by columns, which causes beam compression force different from the applied PT force. This study proposes an analytical method for evaluating column bending stiffness and beam compression force by modeling column deformation according to gap-openings at all stories. The predicted compression forces in the beams are validated by a cyclic analysis of a three-story PT frame and by cyclic tests of a full-scale, two-bay by first-story PT frame, which represents a substructure of the three-story PT frame. The proposed method shows that compared with the strand tensile force, the beam compression force is increased at the 1st story but is decreased at the 2nd and 3rd stories due to column deformation compatibility. The PT frame tests show that the proposed method reasonably predicts beam compression force and strand force and that the beam compression force is 2 and 60% larger than the strand force with respect to a minor restraint and a pin-supported boundary condition, respectively, at the tops of the columns. Therefore, the earlier method using a pin-supported boundary condition at upper story columns represents an upper bound of the effect and is shown to be overly conservative for cases where a structure responds primarily in its first mode. The proposed method allows for more accurate prediction of the column restraint effects for structures that respond in a pre-determined mode shape which is more typical of low and mid-rise structures. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:751 / 774
页数:24
相关论文
共 18 条
[1]  
[Anonymous], IBC INT BUILD COD
[2]  
CHOU CC, 2005, 1 INT C ADV EXP STRU
[3]   Performance evaluation of steel reduced flange plate moment connections [J].
Chou, Chung-Che ;
Wu, Chia-Ching .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2007, 36 (14) :2083-2097
[4]   Evaluating performance of post-tensioned steel connections with strands and reduced flange plates [J].
Chou, Chung-Che ;
Chen, Jun-Hen ;
Chen, Yu-Chih ;
Tsai, Keh-Chyuan .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2006, 35 (09) :1167-1185
[5]   Post-tensioned self-centering moment connections with beam bottom flange energy dissipators [J].
Chou, Chung-Che ;
Lai, Yu-Jen .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (10-11) :1931-1941
[6]   Seismic design and behavior of post-tensioned steel connections including effects of a composite slab [J].
Chou, Chung-Che ;
Wang, Yu-Chi ;
Chen, Jun-Hen .
ENGINEERING STRUCTURES, 2008, 30 (11) :3014-3023
[7]   Self-centering steel connections with steel bars and a discontinuous composite slab [J].
Chou, Chung-Che ;
Tsai, Keh-Chyuan ;
Yang, Wen-Chia .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2009, 38 (04) :403-422
[8]   Posttensioned energy dissipating connections for moment-resisting steel frames [J].
Christopoulos, C ;
Filiatrault, A ;
Uang, CM ;
Folz, B .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2002, 128 (09) :1111-1120
[9]  
Christopoulos C., 2002, P 7 US NAT C EARTHQ
[10]  
CHRISTOPOULOS C, 2002, SSRP200206 U CAL DEP