A mercury-free electrochemical sensor for the determination of thallium(I) based on the rotating-disc bismuth film electrode

被引:70
作者
Jorge, E. O.
Neto, M. M. M.
Rocha, M. M.
机构
[1] Univ Lisbon, Fac Ciencias, Ctr Ciencias Mol & Mat, Dept Quim & Bioquim, P-1749016 Lisbon, Portugal
[2] Univ Tecn Lisboa, Inst Super Agron, Dept Quim Agr & Ambiental, P-1349017 Lisbon, Portugal
关键词
thallium; bismuth film electrode; squarewave voltammetry; anodic stripping voltammetry; mercury-free electrodes;
D O I
10.1016/j.talanta.2007.01.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A bismuth film electrode was tested and proposed as an environmentally friendly sensor for the determination of trace levels of Tl(I) in non-deoxygenated solutions. Determination of thallium was made by anodic stripping voltammetry at a rotating-disc bismuth film electrode plated in situ, using acetate buffer as the supporting electrolyte. The stripping step was carried out by a square wave potential-time excitation signal. A univariate optimisation study was performed with several experimental parameters as variables. Under the selected optimised conditions, a linear calibration plot was obtained in the submicromolar concentration range, allowing the electrochemical determination of thallium in trace amounts; the calculated detection limit was 10.8 nM and the relative standard deviation for 15 measurements of 0.1 mu M Tl(I) was +/-0.2%, for a 120 s accumulation time. Interference of other metals on the response of Tl(I) was investigated. Application to real environmental samples was tested. The bismuth film electrode appears to be a promising tool for electroanalytical purposes, ensuring the use of clean methodology. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1392 / 1399
页数:8
相关论文
共 49 条
[1]   Stripping voltammetry for the determination of trace metal speciation and in-situ measurements of trace metal distributions in marine waters [J].
Achterberg, EP ;
Braungardt, C .
ANALYTICA CHIMICA ACTA, 1999, 400 :381-397
[2]   Characteristics of subtractive anodic stripping voltammetry of lead, cadmium and thallium at silver-gold alloy electrodes [J].
Bonfil, Y ;
Brand, M ;
Kirowa-Eisner, E .
ELECTROANALYSIS, 2003, 15 (17) :1369-1376
[4]   Trace determination of chromium by square-wave adsorptive stripping voltammetry on bismuth film electrodes [J].
Chatzitheodorou, E ;
Economou, A ;
Voulgaropoulos, A .
ELECTROANALYSIS, 2004, 16 (21) :1745-1754
[5]   THE INFLUENCE OF LONG-CHAIN AMINE AND AMMONIUM-SALTS ON THE ANODIC-STRIPPING VOLTAMMETRY OF THALLIUM, LEAD, TIN, CADMIUM AND INDIUM [J].
CISZEWSKI, A ;
LUKASZEWSKI, Z .
ANALYTICA CHIMICA ACTA, 1983, 146 (FEB) :51-59
[6]   POTENTIOMETRIC STRIPPING ANALYSIS OF THALLIUM IN NATURAL-WATERS [J].
CLEVEN, R ;
FOKKERT, L .
ANALYTICA CHIMICA ACTA, 1994, 289 (02) :215-221
[7]  
COPELAND TR, 1974, ANAL CHEM, V46, P1257
[8]   Determination of thallium in water samples [J].
Das, Arabinda K. ;
Dutta, Milli ;
Cervera, M. Luisa ;
de la Guardia, Miguel .
MICROCHEMICAL JOURNAL, 2007, 86 (01) :2-8
[9]   Determination of thallium and cadmium on a chemically modified electrode with Langmuir-Blodgett film of p-allylcalix[4]arene [J].
Dong, HM ;
Zheng, H ;
Lin, L ;
Ye, BX .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 115 (01) :303-308
[10]   Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes [J].
Filipe, OMS ;
Brett, CMA .
TALANTA, 2003, 61 (05) :643-650