Energy retrofitting strategies for office buildings in hot arid climate

被引:12
作者
Rached, Ehab [1 ]
Anber, Maha [2 ]
机构
[1] Umm Al Qura Univ, Fac Engn, Islamic Architecture Dept, Mecca 21961, Saudi Arabia
[2] El shorouk Acad, Higher Inst Engn, Cairo 11837, Egypt
关键词
office buildings; Cairo; DesignBuilder; hot arid climate; energy retrofitting; MULTIOBJECTIVE OPTIMIZATION; GREEN RETROFIT; SIMULATIONS; CONSUMPTION; EFFICIENCY;
D O I
10.1093/ijlct/ctac031
中图分类号
O414.1 [热力学];
学科分类号
摘要
The building sector consumes similar to 30% of the primary energy consumption. Energy retrofitting of buildings contributes greatly to reducing energy consumption and carbon emissions. This research aims at revealing the potential energy savings resulting from applying energy retrofitting strategies to office buildings in hot arid climate. The study is applied on Cairo, Egypt, representing the hot arid climate. The case study building was selected to be an existing office building with an area of 12 000 m(2). The energy simulation software used is the Design Builder software. The suggested retrofitting strategies are upgrading the lighting systems to use LED lights, upgrading the air conditioning performance, using external shading devices, improving AC efficiency, improving the building's air tightness and improving the R-value of the building envelope by using insulation for exterior walls and roof and substituting the existing window glazing. Those strategies were applied to the building for evaluating their potential for achieving energy savings. The conclusion of the applied study was that by combining the most effective strategies has resulted in annual energy consumption reduction by 86%.
引用
收藏
页码:506 / 512
页数:7
相关论文
共 19 条
[1]   Retrofits for Energy Efficient Office Buildings: Integration of Optimized Photovoltaics in the Form of Responsive Shading Devices [J].
Abdullah, Hardi K. ;
Alibaba, Halil Z. .
SUSTAINABILITY, 2017, 9 (11)
[2]   Window retrofit strategy for energy saving in existing residences with different thermal characteristics and window sizes [J].
Ahn, Byung-Lip ;
Kim, Jong-Hun ;
Jang, Cheol-Yong ;
Leigh, Seung-Bok ;
Jeong, Hakgeun .
BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2016, 37 (01) :18-32
[3]   A multi-objective optimization model for building retrofit strategies using TRNSYS simulations, GenOpt and MATLAB [J].
Asadi, Ehsan ;
da Silva, Manuel Gameiro ;
Antunes, Carlos Henggeler ;
Dias, Luis .
BUILDING AND ENVIRONMENT, 2012, 56 :370-378
[4]   Building envelope design: Multi-objective optimization to minimize energy consumption, global cost and thermal discomfort. Application to different Italian climatic zones [J].
Ascione, Fabrizio ;
Bianco, Nicola ;
Mauro, Gerardo Maria ;
Napolitano, Davide Ferdinando .
ENERGY, 2019, 174 :359-374
[5]   Determining retrofit technologies for building energy performance [J].
Benzar, Bianca-Elena ;
Park, Moonseo ;
Lee, Hyun-Soo ;
Yoon, Inseok ;
Cho, Jongwoo .
JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2020, 19 (04) :367-383
[6]   Energy consumption and efficiency technology measures in European non-residential buildings [J].
D'Agostino, Delia ;
Cuniberti, Barbara ;
Bertoldi, Paolo .
ENERGY AND BUILDINGS, 2017, 153 :72-86
[7]   Envelope retrofit in hot arid climates [J].
Edeisy, Mohamed ;
Cecere, Carlo .
SUSTAINABLE SYNERGIES FROM BUILDINGS TO THE URBAN SCALE, 2017, 38 :264-273
[8]   Analysis of annual heating and cooling energy requirements for office buildings in different climates in Turkey [J].
Eskin, Nurdil ;
Tuerkmen, Hamdi .
ENERGY AND BUILDINGS, 2008, 40 (05) :763-773
[9]  
Hanna G.B., 2011, Journal of Energy and Power Engineering, V5, P1134
[10]  
Hartungi R, 2011, SMART INNOV SYST TEC, V7, P1