In situ determination of antimony isotope ratios in Sb minerals by femtosecond LA-MC-ICP-MS

被引:15
|
作者
Kaufmann, A. B. [1 ,2 ]
Lazarov, M. [1 ]
Kiefer, S. [2 ]
Majzlan, J. [2 ]
Weyer, S. [1 ]
机构
[1] Leibniz Univ Hannover, Inst Mineral, Hannover, Germany
[2] Friedrich Schiller Univ Jena, Inst Geosci, Jena, Germany
关键词
PLASMA-MASS SPECTROMETRY; LASER-ABLATION; ULTRAVIOLET-FEMTOSECOND; PRECISE DETERMINATION; PURIFICATION METHOD; FRACTIONATION; MOBILITY; PEZINOK; SYSTEM; COPPER;
D O I
10.1039/d1ja00089f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Here we present a method for in situ determination of stable antimony (Sb) isotope compositions by ultraviolet (UV)-femtosecond-laser-ablation-multi-collector-ICP-MS (fs-LA-MC-ICP-MS). Metallic antimony and a number of Sb minerals (stibnite, senarmontite, chalcostibite, tetrahedrite, boulangerite, bournonite, zinkenite, pyrargyrite and dyscrasite) have been investigated. In order to verify the results of the in situ method, LA-MC-ICP-MS measurements were compared with solution MC-ICP-MS analyses on two chemically homogeneous stibnite samples and Sb metal. The internal precision of in situ measurements was better than 0.045 parts per thousand. The long-term reproducibility for these three materials was better than 0.1 parts per thousand. These results imply that any of these three materials may be used as an in situ Sb isotope standard. All delta Sb-123 values were determined by applying a standard-sample bracketing protocol and mass bias correction using Sn (NIST SRM 3161a standard solution) isotope ratios. Since no certified Sb isotope standard is currently available, in situ isotope analyses were performed in bracketing to a stibnite in-house standard and subsequently recalculated relative to NIST SRM 3102a. Matrix effects from Cu, Pb, Ag, Fe and Zn on the natural mineral Sb isotope ratios were insignificant. The mass interference of Te-123 on Sb-123 can only precisely be corrected for materials with Te/Sb <= 0.2. The LA and solution analyses of delta Sb-123 homogeneous zinkenite, dyscrasite and pyrargyrite agree excellently with each other. Senarmontite shows more variable delta Sb-123 at small scales, determined with LA-MC-ICP-MS, but homogeneous delta Sb-123 determined by solution analyses with a small offset between solution and LA analyses. Other minerals, like boulangerite, show heterogeneous delta Sb-123 (approximate to 0.5 parts per thousand) for both solution and LA analyses. Overall, these results demonstrate that fs-LA-MC-ICP-MS is suitable to measure Sb isotopic ratios in Sb-rich sulfides, sulfosalts and oxides (excluding Sb tellurides) with a precision better than 0.1 parts per thousand and a spatial resolution of approximate to 30 mu m. Thus, it may be used as a tool to analyse spatially resolved Sb isotope composition at the mineral or even sub-mineral scale, e.g. to address the processes of ore formation or Sb redistribution in near-surface environments.
引用
收藏
页码:1554 / 1567
页数:14
相关论文
共 50 条
  • [41] U-Th-Pb geochronology and simultaneous analysis of multiple isotope systems in geological samples by LA-MC-ICP-MS
    Xie, Lie-Wen
    Evans, Noreen J.
    Yang, Yue-Heng
    Huang, Chao
    Yang, Jin-Hui
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (10) : 1600 - 1615
  • [42] Analytical feasibility of a new reference material (IRMM-524A Fe metal) for the in situ Fe isotopic analysis of pyrite and ilmenite without matrix effects by femtosecond LA-MC-ICP-MS
    Xu, Lei
    Yang, Jin-Hui
    Wang, Hao
    Xie, Lie-Wen
    Yang, Yue-Heng
    Huang, Chao
    Wu, Shi-Tou
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (09) : 1835 - 1845
  • [43] Direct lead isotope analysis in Hg-rich sulfides by LA-MC-ICP-MS with a gas exchange device and matrix-matched calibration
    Zhang, Wen
    Hu, Zhaochu
    Gunther, Detlef
    Liu, Yongsheng
    Ling, Wenli
    Zong, Keqing
    Chen, Haihong
    Gao, Shan
    ANALYTICA CHIMICA ACTA, 2016, 948 : 9 - 18
  • [44] Precise and accurate isotopic analysis of microscopic uranium-oxide grains using LA-MC-ICP-MS
    Lloyd, Nicholas S.
    Parrish, Randall R.
    Horstwood, Matthew S. A.
    Chenery, Simon R. N.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (06) : 752 - 758
  • [45] Precise and Accurate In Situ Determination of Lead Isotope Ratios in NIST, USGS, MPI-DING and CGSG Glass Reference Materials using Femtosecond Laser Ablation MC-ICP-MS
    Chen Kaiyun
    Yuan Honglin
    Bao Zhian
    Zong Chunlei
    Dai Mengning
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2014, 38 (01) : 5 - 21
  • [46] Preparation of standards for in situ sulfur isotope measurement in sulfides using femtosecond laser ablation MC-ICP-MS
    Chen, Lu
    Chen, Kaiyun
    Bao, Zhian
    Liang, Peng
    Sun, Tiantian
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (01) : 107 - 116
  • [47] Early Holocene Scandinavian foragers on a journey to affluence: Mesolithic fish exploitation, seasonal abundance and storage investigated through strontium isotope ratios by laser ablation (LA-MC-ICP-MS)
    Boethius, Adam
    Kjaellquist, Mathilda
    Kielman-Schmitt, Melanie
    Ahlstroem, Torbjoern
    Larsson, Lars
    PLOS ONE, 2021, 16 (01):
  • [48] Lead isotope homogeneity of NIST SRM 610 and 612 glass reference materials: Constraints from laser ablation multicollector ICP-MS (LA-MC-ICP-MS) analysis
    Kent, Adam J. R.
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2008, 32 (02) : 129 - 147
  • [49] Cadmium Isotope Ratios of Standard Solutions and Geological Reference Materials Measured by MC-ICP-MS
    Li, Dandan
    Li, Meng-Lun
    Liu, Wen-Ran
    Qin, Zhen-Zhen
    Liu, Sheng-Ao
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2018, 42 (04) : 593 - 605
  • [50] In-situ determination of Nd isotope ratios in apatite by LA-MC-ICPMS: Challenges and limitations
    Doucelance, Regis
    Bruand, Emilie
    Matte, Simon
    Bosq, Chantal
    Auclair, Delphine
    Gannoun, Abdel-Mouhcine
    CHEMICAL GEOLOGY, 2020, 550