In situ determination of antimony isotope ratios in Sb minerals by femtosecond LA-MC-ICP-MS

被引:15
|
作者
Kaufmann, A. B. [1 ,2 ]
Lazarov, M. [1 ]
Kiefer, S. [2 ]
Majzlan, J. [2 ]
Weyer, S. [1 ]
机构
[1] Leibniz Univ Hannover, Inst Mineral, Hannover, Germany
[2] Friedrich Schiller Univ Jena, Inst Geosci, Jena, Germany
关键词
PLASMA-MASS SPECTROMETRY; LASER-ABLATION; ULTRAVIOLET-FEMTOSECOND; PRECISE DETERMINATION; PURIFICATION METHOD; FRACTIONATION; MOBILITY; PEZINOK; SYSTEM; COPPER;
D O I
10.1039/d1ja00089f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Here we present a method for in situ determination of stable antimony (Sb) isotope compositions by ultraviolet (UV)-femtosecond-laser-ablation-multi-collector-ICP-MS (fs-LA-MC-ICP-MS). Metallic antimony and a number of Sb minerals (stibnite, senarmontite, chalcostibite, tetrahedrite, boulangerite, bournonite, zinkenite, pyrargyrite and dyscrasite) have been investigated. In order to verify the results of the in situ method, LA-MC-ICP-MS measurements were compared with solution MC-ICP-MS analyses on two chemically homogeneous stibnite samples and Sb metal. The internal precision of in situ measurements was better than 0.045 parts per thousand. The long-term reproducibility for these three materials was better than 0.1 parts per thousand. These results imply that any of these three materials may be used as an in situ Sb isotope standard. All delta Sb-123 values were determined by applying a standard-sample bracketing protocol and mass bias correction using Sn (NIST SRM 3161a standard solution) isotope ratios. Since no certified Sb isotope standard is currently available, in situ isotope analyses were performed in bracketing to a stibnite in-house standard and subsequently recalculated relative to NIST SRM 3102a. Matrix effects from Cu, Pb, Ag, Fe and Zn on the natural mineral Sb isotope ratios were insignificant. The mass interference of Te-123 on Sb-123 can only precisely be corrected for materials with Te/Sb <= 0.2. The LA and solution analyses of delta Sb-123 homogeneous zinkenite, dyscrasite and pyrargyrite agree excellently with each other. Senarmontite shows more variable delta Sb-123 at small scales, determined with LA-MC-ICP-MS, but homogeneous delta Sb-123 determined by solution analyses with a small offset between solution and LA analyses. Other minerals, like boulangerite, show heterogeneous delta Sb-123 (approximate to 0.5 parts per thousand) for both solution and LA analyses. Overall, these results demonstrate that fs-LA-MC-ICP-MS is suitable to measure Sb isotopic ratios in Sb-rich sulfides, sulfosalts and oxides (excluding Sb tellurides) with a precision better than 0.1 parts per thousand and a spatial resolution of approximate to 30 mu m. Thus, it may be used as a tool to analyse spatially resolved Sb isotope composition at the mineral or even sub-mineral scale, e.g. to address the processes of ore formation or Sb redistribution in near-surface environments.
引用
收藏
页码:1554 / 1567
页数:14
相关论文
共 50 条
  • [31] Single Spot Rb-Sr Isochron Dating of Biotite by LA-MC-ICP-MS/MS
    Cruz-Uribe, Alicia M.
    Craig, Grant
    Garber, Joshua M.
    Paul, Bence
    Arkula, Cemil
    Bouman, Claudia
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2023, 47 (04) : 795 - 809
  • [32] Boron isotope ratio determination in carbonates via LA-MC-ICP-MS using soda-lime glass standards as reference material
    Fietzke, Jan
    Heinemann, Agnes
    Taubner, Isabelle
    Boehm, Florian
    Erez, Jonathan
    Eisenhauer, Anton
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (12) : 1953 - 1957
  • [33] U-Pb zircon in situ dating with LA-MC-ICP-MS using a mixed detector configuration
    Chemale, Farid, Jr.
    Kawashita, Koji
    Dussin, Ivo A.
    Avila, Janaina N.
    Justino, Dayvisson
    Bertotti, Anelise
    ANAIS DA ACADEMIA BRASILEIRA DE CIENCIAS, 2012, 84 (02): : 275 - 295
  • [34] Trends in analytical developments and earth science applications in LA-ICP-MS and LA-MC-ICP-MS for 2004 and 2005
    Sylvester, Paul J.
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2006, 30 (03) : 197 - 207
  • [35] In situ measurement of Sm-Nd isotopic ratios in geological materials with Nd < 100 μg g-1 by LA-MC-ICP-MS
    Zhang, Le
    Yang, Fan
    Hong, Lu-Bing
    Zhang, Yan
    Soldner, Jeremie
    Zhang, Yan-Qiang
    Ren, Zhong-Yuan
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (09) : 1776 - 1786
  • [36] High precision determination of silver isotope ratios in commercial products by MC-ICP-MS
    Yang, Lu
    Dabek-Zlotorzynska, Ewa
    Celo, Valbona
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (11) : 1564 - 1569
  • [37] Zinc isotope ratio imaging of rat brain thin sections from stable isotope tracer studies by LA-MC-ICP-MS
    Urgast, Dagmar S.
    Hill, Sarah
    Kwun, In-Sook
    Beattie, John H.
    Goenaga-Infante, Heidi
    Feldmann, Joerg
    METALLOMICS, 2012, 4 (10) : 1057 - 1063
  • [38] Iron Distribution in Size-Resolved Aerosols Generated by UV-Femtosecond Laser Ablation: Influence of Cell Geometry and Implications for In Situ Isotopic Determination by LA-MC-ICP-MS
    d'Abzac, Francois-Xavier
    Czaja, Andrew D.
    Beard, Brian L.
    Schauer, James J.
    Johnson, Clark M.
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2014, 38 (03) : 293 - 309
  • [39] An improved U-Pb age dating method for detrital zircon by LA-MC-ICP-MS
    Zhang, Le
    Ren, Zhong-Yuan
    Xia, Xiao-Ping
    Wang, Ce
    Qian, Sheng-Ping
    GEOCHEMICAL JOURNAL, 2018, 52 (05) : 433 - 439
  • [40] Accurate determination of Cu isotope compositions in Cu-bearing minerals using microdrilling and MC-ICP-MS
    Lv, Nan
    Bao, Zhian
    Chen, Lu
    Chen, Kaiyun
    Zhang, Yan
    Yuan, Honglin
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2020, 457