Ultrasound of the horizontal rectus muscle insertion sites: Implications in preoperative assessment of strabismus

被引:26
作者
Tamburrelli, C [1 ]
Salgarello, T [1 ]
Vaiano, AS [1 ]
Scullica, L [1 ]
Palombi, M [1 ]
Bagolini, B [1 ]
机构
[1] Univ Sacred Heart, Ist Oftalmol, I-00168 Rome, Italy
关键词
D O I
10.1167/iovs.02-0112
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To determine the reproducibility and accuracy of ultrasonographic (LIS) measurements of distances between the corneoscleral limbus and the insertion bite of the medial (MR) or lateral rectus (LR) muscle compared with intraoperative measurements in patients with strabismus. METHODS. One eye in each of 17 patients with postoperative secondary strabismus caused by over- or undercorrected eso-and exotropia and one eye of each of 19 patients with previously untreated strabismus underwent five repeated measurements by high-resolution ultrasonography of the distance from the corneoscleral limbus to the muscle insertion and three actual intraoperative measurements. Reproducibility, expressed as the coefficient of variation, accuracy (relative error) of US measurements, and the agreement with intraoperative measurements were assessed. RESULTS. The coefficients of variation for US data were 2.02% and 18% for the MR and 7.33% and 11.77% for the LR, in the surgical and untreated groups, respectively. The relative error was 6.15% +/- 8.14% (mean +/- SD) and 3.66% +/- 12.83% for the MR muscle, and 12.21% +/- 10.66% and -7.69% +/- 7.83% for the LR muscle, in the surgical and untreated groups, respectively. The 95% limits of agreement (mean 2 SD) between the US and intraoperative measurements were 0.65 +/- 1.82 and 0.15 +/- 1.42 ram for the MR muscle, and 1.12 +/- 2.01 and -0.49 +/- 0.98 mm for the LR muscle, in the surgical and untreated groups, respectively. CONCLUSIONS. The results indicate good reliability and accuracy of US readings and suggest a potential usefulness in preoperative assessment of patients with strabismus with surgical failure and missing preoperative clinical data.
引用
收藏
页码:618 / 622
页数:5
相关论文
共 29 条
[1]  
Apt L, 1980, Trans Am Ophthalmol Soc, V78, P365
[2]   CINE MAGNETIC-RESONANCE-IMAGING OF EYE-MOVEMENTS [J].
BAILEY, CC ;
KABALA, J ;
LAITT, R ;
WESTON, M ;
GODDARD, P ;
HOH, HB ;
POTTS, MJ ;
HARRAD, RA .
EYE, 1993, 7 :691-693
[3]  
BARSOUMHOMSY M, 1981, CAN J OPHTHALMOL, V16, P181
[4]  
Bietti GB, 1965, J PEDIAT OPHTHALMOL, V2, P11
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
BUSCHMANN W, 1970, Ophthalmic Research, V1, P354
[7]  
BYRNE SF, 1992, ULTRASOUND EYE ORBIT, P1
[8]  
CADERA W, 1992, J PEDIATR OPHTHALMOL, V29, P120
[9]  
Dunlap E, 1971, NEW ORLEANS ACAD OPH, P255
[10]  
DUNNINGTON JH, 1950, ARCH OPHTHALMOL-CHIC, V44, P813