Design and experimental verification of thin acoustic lenses for the coagulation of large tissue volumes

被引:31
作者
Fjield, T
Sorrentino, V
Cline, H
Hynynen, K
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Radiol, Boston, MA 02115 USA
[2] GE Co, Corp Res & Dev, Schenectady, NY 12309 USA
关键词
D O I
10.1088/0031-9155/42/12/003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Large focal volumes are desired in ultrasound surgery to reduce the total treatment time when large tumours are thermally coagulated. Phased arrays are capable of producing enlarged focal volumes in addition to providing the ability for on-line modification of focal shape and location. Although phased arrays have several advantages over their non-phased counterparts, the complexity of these arrays also presents some disadvantages regarding cost and complexity. One less costly alternative is the use of thin acoustic lenses to alter the field shape of a single-focus transducer. Four polystyrene lenses have been designed using the sector-vortex principle developed for phased arrays by Cain and Umemura. Measurements of the acoustic fields produced with the lenses are in good agreement with the simulated fields. The transmission measurements through each of the four lenses ranged from 76% to 84%, and over 52 W of total acoustic power has been delivered through each of the lenses during in vivo experiments without any damage to the lenses or the transducer. The in vivo results showed an increase in rate of necrosis to 10.1 +/- 1.4 cm(3) h(-1) using the mode 4 lens, or 5.2 +/- 0.7 times higher than the focused transducer alone.
引用
收藏
页码:2341 / 2354
页数:14
相关论文
共 26 条
[1]  
[Anonymous], 2012, ESSENTIALS MED ULTRA
[2]   HIGH-INTENSITY FOCUSED ULTRASOUND IN THE TREATMENT OF PROSTATIC TISSUE [J].
BIHRLE, R ;
FOSTER, RS ;
SANGHVI, NT ;
FRY, FJ ;
DONOHUE, JP .
UROLOGY, 1994, 43 (02) :21-26
[3]   EFFECTS OF PHYSICAL PARAMETERS ON HIGH-TEMPERATURE ULTRASOUND HYPERTHERMIA [J].
BILLARD, BE ;
HYNYNEN, K ;
ROEMER, RB .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (04) :409-420
[4]   CONCENTRIC-RING AND SECTOR-VORTEX PHASED-ARRAY APPLICATORS FOR ULTRASOUND HYPERTHERMIA [J].
CAIN, CA ;
UMEMURA, S .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1986, 34 (05) :542-551
[5]  
CHAPELON JY, 1993, ULTRASON, P1211, DOI 10.1109/ULTSYM.1993.339615
[6]  
Chung A, 1996, P SMR 4 M, P1751
[7]   FOCUSED US SYSTEM FOR MR IMAGING-GUIDED TUMOR ABLATION [J].
CLINE, HE ;
HYNYNEN, K ;
WATKINS, RD ;
ADAMS, WJ ;
SCHENCK, JF ;
ETTINGER, RH ;
FREUND, WR ;
VETRO, JP ;
JOLESZ, FA .
RADIOLOGY, 1995, 194 (03) :731-737
[8]   Ultrasound surgery using multiple sonications - Treatment time considerations [J].
Fan, XB ;
Hynynen, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (04) :471-482
[9]   The combined concentric-ring and sector-vortex phased array for MRI guided ultrasound surgery [J].
Fjield, T ;
Hynynen, K .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (05) :1157-1167
[10]   A parametric study of the concentric-ring transducer design for MRI guided ultrasound surgery [J].
Fjield, T ;
Fan, XB ;
Hynynen, K .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 100 (02) :1220-1230