Imaging of the coronary arteries by means of multislice helical CT: Optimization of image quality with multisegmental reconstruction and variable gantry rotation time

被引:0
作者
Lembcke, A
Rogalla, P
Mews, J
Blobel, J
Enzweiler, CNH
Wiese, TH
Hermann, KGA
Hamm, B
机构
[1] Humboldt Univ, Inst Radiol, Univ Klinikum Charite, D-10098 Berlin, Germany
[2] Toshiba Med Syst, Neuss, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2003年 / 175卷 / 06期
关键词
computed tomography (CT); heart; coronary vessels; SPIRAL COMPUTED-TOMOGRAPHY; MULTIDETECTOR-ROW CT; MOTION ARTIFACTS; HEART-RATE; ANGIOGRAPHY; STENOSES; VISUALIZATION; MULTIPLANAR;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the potential of multisegmental reconstruction and variable gantry rotation time for reducing motion-induced artifacts in coronary artery imaging by multislice helical CT. Materials and Methods: The data sets of 20 patients (8 with HR < 60 bpm, 12 with HR > 60 bpm) were analyzed. The patients underwent multislice helical CT (Aquilion 8, Toshiba, Otawara, Japan) using the following parameters: 0.5 mm slice thickness, 250 mA, 120 W, pitch of 0.25 and variable gantry rotation times of 400, 500, or 600 msec. Images were generated by halfscan and multisegmental reconstruction. In 9 coronary segments of each patient, the presence and severity of motion artifacts were assessed and graded on a scale between 5 (no artifacts) and 1 (heaviest artifacts). Results: Diagnostically relevant motion artifacts were rare at low heart rates (< 60 bpm) for both types of image reconstruction (4% of all segments). Higher heart rates (> 60 bpm) were associated with an increase in motion artifacts on halfscan reconstructions (33% of all segments, p < 0.05) but not on multisegmental reconstructions (4% of all segments). At low heart rates mean image quality did not differ between multisegmental and halfscan reconstruction (4.28 +/- 0.37 vs. 4.22 +/- 0.41; p > 0.05), whereas at higher heart rates image quality was better for multisegmental reconstruction than for halfscan reconstruction (4.23 +/- 0.47 vs. 3.11 +/- 0.63; p < 0.05). Conclusion: Multisegmental reconstruction with variable gantry rotation times suppresses motion artifacts and thus improves assessment of the coronary arteries in patients with higher heart rates.
引用
收藏
页码:780 / 785
页数:6
相关论文
共 21 条
  • [1] Achenbach S, 2001, CIRCULATION, V103, P2535
  • [2] In-plane coronary arterial motion velocity: Measurement with electron-beam CT
    Achenbach, S
    Ropers, D
    Holle, J
    Muschiol, G
    Daniel, WG
    Moshage, W
    [J]. RADIOLOGY, 2000, 216 (02) : 457 - 463
  • [3] Current development of cardiac imaging with multidetector-row CT
    Becker, CR
    Ohnesorge, BM
    Schoepf, UJ
    Reiser, MF
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2000, 36 (02) : 97 - 103
  • [4] Erhard K, 2002, ROFO FORTSCHR RONTG, V174, P1566
  • [5] New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac Imaging
    Flohr, T
    Bruder, H
    Stierstorfer, K
    Simon, J
    Schaller, S
    Ohnesorge, B
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08): : 1022 - 1027
  • [6] Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart
    Flohr, T
    Ohnesorge, B
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) : 907 - 923
  • [7] The optimal time point in RR interval for data reconstructioin to visualize coronary arteries by multi slice computed tomography.
    Georg, C
    Kopp, A
    Schröder, S
    Küttner, A
    Ohnesorge, B
    Martensen, J
    Clausen, CD
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (06): : 536 - 541
  • [8] Image quality in a standardized algorithm for minimally invasive coronary angiography with multislice spiral computed tomography
    Gerber, TC
    Kuzo, RS
    Lane, GE
    O'Brien, PC
    Karstaedt, N
    Morin, RL
    Safford, RE
    Blackshear, JL
    Pietan, JH
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (01) : 62 - 69
  • [9] Characterization of motion artifacts in multi-slice spiral CT
    Graf, H
    Heuschmid, M
    Küttner, A
    Kopp, AF
    Claussen, CD
    Schick, F
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (10): : 1301 - 1308
  • [10] Visualization techniques for multislice CT datasets of coronary arteries: Correlation of axial, multiplanar, three-dimensional, and virtual endoscopic imaging with coronary angiography
    Herzog, C
    Ay, M
    Engelmann, K
    Abolmaali, N
    Dogani, S
    Diebold, T
    Vogl, TJ
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (04): : 341 - 349