Imaging of the coronary arteries by means of multislice helical CT: Optimization of image quality with multisegmental reconstruction and variable gantry rotation time

被引:0
作者
Lembcke, A
Rogalla, P
Mews, J
Blobel, J
Enzweiler, CNH
Wiese, TH
Hermann, KGA
Hamm, B
机构
[1] Humboldt Univ, Inst Radiol, Univ Klinikum Charite, D-10098 Berlin, Germany
[2] Toshiba Med Syst, Neuss, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2003年 / 175卷 / 06期
关键词
computed tomography (CT); heart; coronary vessels; SPIRAL COMPUTED-TOMOGRAPHY; MULTIDETECTOR-ROW CT; MOTION ARTIFACTS; HEART-RATE; ANGIOGRAPHY; STENOSES; VISUALIZATION; MULTIPLANAR;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the potential of multisegmental reconstruction and variable gantry rotation time for reducing motion-induced artifacts in coronary artery imaging by multislice helical CT. Materials and Methods: The data sets of 20 patients (8 with HR < 60 bpm, 12 with HR > 60 bpm) were analyzed. The patients underwent multislice helical CT (Aquilion 8, Toshiba, Otawara, Japan) using the following parameters: 0.5 mm slice thickness, 250 mA, 120 W, pitch of 0.25 and variable gantry rotation times of 400, 500, or 600 msec. Images were generated by halfscan and multisegmental reconstruction. In 9 coronary segments of each patient, the presence and severity of motion artifacts were assessed and graded on a scale between 5 (no artifacts) and 1 (heaviest artifacts). Results: Diagnostically relevant motion artifacts were rare at low heart rates (< 60 bpm) for both types of image reconstruction (4% of all segments). Higher heart rates (> 60 bpm) were associated with an increase in motion artifacts on halfscan reconstructions (33% of all segments, p < 0.05) but not on multisegmental reconstructions (4% of all segments). At low heart rates mean image quality did not differ between multisegmental and halfscan reconstruction (4.28 +/- 0.37 vs. 4.22 +/- 0.41; p > 0.05), whereas at higher heart rates image quality was better for multisegmental reconstruction than for halfscan reconstruction (4.23 +/- 0.47 vs. 3.11 +/- 0.63; p < 0.05). Conclusion: Multisegmental reconstruction with variable gantry rotation times suppresses motion artifacts and thus improves assessment of the coronary arteries in patients with higher heart rates.
引用
收藏
页码:780 / 785
页数:6
相关论文
共 21 条
[1]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[2]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[3]   Current development of cardiac imaging with multidetector-row CT [J].
Becker, CR ;
Ohnesorge, BM ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN JOURNAL OF RADIOLOGY, 2000, 36 (02) :97-103
[4]  
Erhard K, 2002, ROFO FORTSCHR RONTG, V174, P1566
[5]   New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac Imaging [J].
Flohr, T ;
Bruder, H ;
Stierstorfer, K ;
Simon, J ;
Schaller, S ;
Ohnesorge, B .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08) :1022-1027
[6]   Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart [J].
Flohr, T ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :907-923
[7]   The optimal time point in RR interval for data reconstructioin to visualize coronary arteries by multi slice computed tomography. [J].
Georg, C ;
Kopp, A ;
Schröder, S ;
Küttner, A ;
Ohnesorge, B ;
Martensen, J ;
Clausen, CD .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (06) :536-541
[8]   Image quality in a standardized algorithm for minimally invasive coronary angiography with multislice spiral computed tomography [J].
Gerber, TC ;
Kuzo, RS ;
Lane, GE ;
O'Brien, PC ;
Karstaedt, N ;
Morin, RL ;
Safford, RE ;
Blackshear, JL ;
Pietan, JH .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (01) :62-69
[9]   Characterization of motion artifacts in multi-slice spiral CT [J].
Graf, H ;
Heuschmid, M ;
Küttner, A ;
Kopp, AF ;
Claussen, CD ;
Schick, F .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (10) :1301-1308
[10]   Visualization techniques for multislice CT datasets of coronary arteries: Correlation of axial, multiplanar, three-dimensional, and virtual endoscopic imaging with coronary angiography [J].
Herzog, C ;
Ay, M ;
Engelmann, K ;
Abolmaali, N ;
Dogani, S ;
Diebold, T ;
Vogl, TJ .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (04) :341-349