Effects of gait support in patients with spinocerebellar degeneration by a wearable robot based on synchronization control

被引:11
|
作者
Tsukahara, Atsushi [1 ,2 ]
Yoshida, Kunihiro [3 ,4 ]
Matsushima, Akira [5 ]
Ajima, Kumiko [4 ]
Kuroda, Chika [6 ]
Mizukami, Noriaki [1 ]
Hashimoto, Minoru [1 ,2 ]
机构
[1] Shinshu Univ, Fac Text Sci & Technol, Dept Mech Engn & Robot, 3-15-1 Tokida, Ueda, Nagano 3868567, Japan
[2] Shinshu Univ, ICCER, Inst Fiber Engn IFES, Ueda, Nagano, Japan
[3] Shinshu Univ, Sch Med, Dept Brain Dis Res, 3-1-1 Asahi, Matsumoto, Nagano 3908621, Japan
[4] Shinshu Univ, ICCER, IBS, Matsumoto, Nagano, Japan
[5] Kakeyu Hosp, Kakeyu Misayama Rehabil Ctr, 1308 Kakeyu, Ueda, Nagano 3860396, Japan
[6] Shinshu Univ, Grad Sch Med, Dept Hlth Sci, 3-1-1 Asahi, Matsumoto, Nagano 3908621, Japan
基金
日本学术振兴会;
关键词
Spinocerebellar degeneration; Gait support; Synchronization control; CENTRAL PATTERN GENERATOR; ACCELERATION PATTERNS; NEURAL OSCILLATORS; HARMONIC RATIOS; WALKING; ATAXIA; EXOSKELETON; ASSISTANCE; STABILITY; MOVEMENTS;
D O I
10.1186/s12984-018-0425-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Spinocerebellar degeneration (SCD) mainly manifests a cerebellar ataxic gait, leading to marked postural sway and the risk of falling down. Gait support using a wearable robot is expected to be an effective solution to maintaining the status quo and/or delaying symptom progression. The aim of this study was to evaluate the effects of gait support in patients with SCD by using a wearable robotic system called curara (R) while undergoing walking tests. Methods: The curara system assists both the hip and knee joints and supports the wearer's rhythmic gait using a synchronization control based on a central pattern generator. The system reflects the wearer's intended motion in response to the gait support by detecting an interactive force that is generated from slight movements of the wearer. The degree of coordinated motion between the robot and the wearer can be adjusted by modifying the synchronization gain. In this study, we provided gait support using three high-gain conditions (A, B, C) to more easily follow the wearer's movement in each joint. The synchronization gains for both the hip and knee joints (i.e., C-h and C-k) were set at 0.5 for condition A and at 0.4 for condition B. Condition C had different gains for the hip and knee joints (i.e., C-h=0.4 and C-k=0.5). With the walking test, we assessed the effects of the gait support provided by the curara system on walking smoothness (measured using the harmonic ratio: HR) and spatiotemporal parameters (gait speed, stride length, cadence) in SCD patients (n=12). We compared the performance between the three high-gain conditions and without assistance from the robot. Results: Under condition C, the HRs in the anteroposterior, mediolateral, and vertical directions (HR-AP, HR-ML, and HR-V) were especially high compared with those under conditions A and B. The results of the statistical analyses using repeated measures analysis of variance followed by Tukey's test showed that gait support with condition C results in a statistically significant increase in the HR-AP (2.04 +/- 0.52; p=0.025) and HR-V (2.06 +/- 0.37; p=0.032) when compared with walking without assistance from the system. In contrast, the gait speed, stride length, and cadence under condition C were no major changes in most patients, compared with the patient's walking without assistance. Conclusions: The significantly increased HR indicates that gait support under condition C achieved smoother walking than when not wearing the power unit of the system. Consequently, we suggest that gait support using the curara system has the potential to improve walking smoothness in patients with SCD.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Effects and Safety of Wearable Exoskeleton for Robot-Assisted Gait Training: A Retrospective Preliminary Study
    Park, Gwang-Min
    Cho, Su-Hyun
    Hong, Jun-Taek
    Kim, Dae-Hyun
    Shin, Ji-Cheol
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (04):
  • [22] Trot Gait Control of Quadruped Robot Based on Inclination of Body
    Horio, Ryosuke
    Uchiyama, Naoki
    Sano, Shigenori
    2014 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS IEEE-ROBIO 2014, 2014, : 2062 - 2067
  • [23] Quadruped robot gait control based on central pattern generator
    Huang B.
    Yao Y.
    Sun L.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2010, 46 (07): : 1 - 6
  • [24] Gait Analysis based Speed Control of Walking Assistive Robot
    Fujimoto, Akane
    Matsumoto, Naoya
    Jiang, Yinlai
    Togo, Shunta
    Teshigawara, Seiichi
    Yokoi, Hiroshi
    2018 IEEE INTERNATIONAL CONFERENCE ON INTELLIGENCE AND SAFETY FOR ROBOTICS (ISR), 2018, : 88 - 92
  • [25] Gait Control System of Autonomous Mobile Robot Based on PMAC
    Si, Guobin
    Jin, Xiaofeng
    Wang, Chunxia
    JORDAN JOURNAL OF MECHANICAL AND INDUSTRIAL ENGINEERING, 2022, 16 (01): : 31 - 40
  • [26] Gait Planning and Control of Hexapod Robot Based on Velocity Vector
    Xue, Junfeng
    Li, Jiehao
    Chen, Zhihua
    Wang, Shoukun
    Wang, Junzheng
    Ma, Ruijun
    2021 6TH IEEE INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS AND MECHATRONICS (ICARM 2021), 2021, : 616 - 620
  • [27] Running Gait and Control of Quadruped Robot Based on SLIP Model
    He, Xiaolong
    Li, Xinjie
    Wang, Xiangji
    Meng, Fantuo
    Guan, Xikang
    Jiang, Zhenyu
    Yuan, Lipeng
    Ba, Kaixian
    Ma, Guoliang
    Yu, Bin
    BIOMIMETICS, 2024, 9 (01)
  • [28] Biped Robot Gait Control Based on Enhanced Capture Point
    Tian, Zhongyuan
    Zhao, Mingguo
    2018 IEEE-RAS 18TH INTERNATIONAL CONFERENCE ON HUMANOID ROBOTS (HUMANOIDS), 2018, : 1107 - 1112
  • [29] Gait control for a snake robot based on hopf oscillator model
    Wang, Zhelong (wangzl@dlut.edu.cn), 1600, Chinese Academy of Sciences (36):
  • [30] Effects of severity of degeneration on gait patterns in patients with medial knee osteoarthritis
    Huang, Shier-Chieg
    Wei, I-Pin
    Chien, Hui-Lien
    Wang, Ting-Ming
    Liu, Yen-Hung
    Chen, Hao-Ling
    Lu, Tung-Wu
    Lin, Jaung-Geng
    MEDICAL ENGINEERING & PHYSICS, 2008, 30 (08) : 997 - 1003