Interpretation of emergency department radiographs: A comparison of emergency medicine physicians with radiologists, residents with faculty, and film with digital display

被引:93
作者
Eng, J
Mysko, WK
Weller, GER
Renard, R
Gitlin, JN
Bluemke, DA
Magid, D
Kelen, GD
Scott, WW
机构
[1] Johns Hopkins Univ, Dept Radiol, Sch Med, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Dept Emergency Med, Sch Med, Baltimore, MD 21287 USA
关键词
D O I
10.2214/ajr.175.5.1751233
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. We determined the relative value of teleradiology and radiology resident coverage of the emergency department by measuring and comparing the effects of physician specialty, training level, and image display method on accuracy of radiograph interpretation. MATERIALS AND METHODS. A sample of four faculty emergency medicine physicians, four emergency medicine residents, four faculty radiologists, and four radiology residents participated in our study. Each physician interpreted 120 radiographs, approximately half containing a clinically important index finding. Radiographs were interpreted using the original films and high-resolution digital monitors. Accuracy of radiograph interpretation was measured as the area under the physicians' receiver operating characteristic (ROC) curves, RESULTS. The area under the ROC curve was 0.15 (95% confidence interval [CI], 0.10-0.20) greater for radiologists than for emergency medicine physicians, 0.07 (95% CI, 0.02-0.12) greater for faculty than for residents, and 0.07 (95% CI, 0.02-0.12) greater for films than for video monitors. Using these results, we estimated that teleradiology coverage by faculty radiologists would add 0.09 (95% CI, 0.03-0.15) to the area under the ROC curve for radiograph interpretation by emergency medicine faculty alone, and radiology resident coverage would add 0.08 (95% CI, 0.02-0.14) to this area. CONCLUSION. We observed significant differences between the interpretation of radiographs on film and on digital monitors. However, we observed differences of equal or greater magnitude associated with the training level and physician specialty of each observer. In evaluating teleradiology services, observer characteristics must be considered in addition to the quality of image display.
引用
收藏
页码:1233 / 1238
页数:6
相关论文
共 18 条
  • [1] *AM COLL RAD, 1998, STAND 1998, P3
  • [2] CHEST RADIOGRAPHY - COMPARISON OF HIGH-RESOLUTION DIGITAL DISPLAYS WITH CONVENTIONAL AND DIGITAL FILM
    COX, GG
    COOK, LT
    MCMILLAN, JH
    ROSENTHAL, SJ
    DWYER, SJ
    [J]. RADIOLOGY, 1990, 176 (03) : 771 - 776
  • [3] RECEIVER OPERATING CHARACTERISTIC RATING ANALYSIS - GENERALIZATION TO THE POPULATION OF READERS AND PATIENTS WITH THE JACKKNIFE METHOD
    DORFMAN, DD
    BERBAUM, KS
    METZ, CE
    [J]. INVESTIGATIVE RADIOLOGY, 1992, 27 (09) : 723 - 731
  • [4] Context bias - A problem in diagnostic radiology
    Egglin, TKP
    Feinstein, AR
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (21): : 1752 - 1755
  • [5] HIGH-RESOLUTION COMPUTER DISPLAY OF PORTABLE, DIGITAL, CHEST RADIOGRAPHS OF ADULTS - SUITABILITY FOR PRIMARY INTERPRETATION
    FRANK, MS
    JOST, RG
    MOLINA, PL
    ANDERSON, DJ
    SOLOMON, SL
    WHITMAN, RA
    MOORE, SM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) : 473 - 477
  • [6] A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES
    HANLEY, JA
    MCNEIL, BJ
    [J]. RADIOLOGY, 1983, 148 (03) : 839 - 843
  • [7] THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE
    HANLEY, JA
    MCNEIL, BJ
    [J]. RADIOLOGY, 1982, 143 (01) : 29 - 36
  • [8] COMPARISON OF 2048-LINE DIGITAL-DISPLAY FORMATS AND CONVENTIONAL RADIOGRAPHS - AN ROC STUDY
    HAYRAPETIAN, A
    ABERLE, DR
    HUANG, HK
    FISKE, R
    MORIOKA, C
    VALENTINO, D
    BOECHAT, MI
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (05) : 1113 - 1118
  • [9] KORSOFF L, 1995, ACTA RADIOL, V36, P37
  • [10] DIGITAL RADIOGRAPHY OF SUBTLE PULMONARY ABNORMALITIES - AN ROC STUDY OF THE EFFECT OF PIXEL SIZE ON OBSERVER PERFORMANCE
    MACMAHON, H
    VYBORNY, CJ
    METZ, CE
    DOI, K
    SABETI, V
    SOLOMON, SL
    [J]. RADIOLOGY, 1986, 158 (01) : 21 - 26