Computer-assisted navigated cup placement in primary and secondary dysplastic hips

被引:21
作者
Haaker, R [1 ]
Tiedjen, K [1 ]
Rubenthaler, F [1 ]
Stockheim, M [1 ]
机构
[1] Ruhr Univ Bochum, St Josef Hosp, Orthopad Klin, Bochum, Germany
来源
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE | 2003年 / 141卷 / 01期
关键词
total hip arthroplasty; dyplastic cases; navigation; cup position; CAS system;
D O I
10.1055/s-2003-37306
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim: The positioning of an acetabular implant has great influence on the range of motion as well as the charger of dislocation of total hip arthroplasty. Using modern CAS systems the reproduction of the cup position after three-dimensional planning based on computed tomography is possible. We investigated the reliability of the position of the acetabular implant in primary and secondary dysplastic cases. Method: Within a prospective randomised study in a total of 100 hip replacements with postoperatively controlled cup position using a computed tomography, we reinvestigated especially the 18 dysplastic and two secondary dysplastic cases. Results: In the dysplastic cases we could realise nearly the same anteversion angles (22.4degrees to 21.5degrees) with a bigger standard deviation ( +/-7.68 to +/-7.29) than in the normal collective. Even the inclination angles (44.5degrees +/-5.47degrees) could be realized nearly the same as in the normal cases (42.3degrees +/- 4.31degrees). The depth of the cup implantation could be realised in 15 of 18 cases. Conclusion: The CAS system is helpful even in dysplastic cases. The advantage of three-dimensional preoperative CT-based planning is apparent. The surgeon is not able to plan and realise the ideal cup position in some individual.
引用
收藏
页码:105 / 111
页数:7
相关论文
共 21 条
  • [1] Ceramic acetabular cups for total hip replacement part 7: How are range of motion and impingement influenced by the position of the centre of rotation and the CCD angle of the stem?
    Bader, R
    Willmann, G
    [J]. BIOMEDIZINISCHE TECHNIK, 1999, 44 (12): : 345 - 351
  • [2] BADER R, 2000, Z ORTHOP, V138, P19
  • [3] Bernsmann K, 2001, Z ORTHOP GRENZGEB, V139, P512
  • [4] Computer assisted navigated cup placement in hip arthroplasty - Application study in clinical routine.
    Bernsmann, K
    Langlotz, U
    Ansari, B
    Wiese, M
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2000, 138 (06): : 515 - 521
  • [5] BUTTNERJANZ K, 1998, Z ORTHOP, V136, pA47
  • [6] Riskfactors for dislocation in cementless hiparthroplasty - A statistical analysis
    Giurea, A
    Zehetgruber, H
    Funovics, P
    Grampp, S
    Karamat, L
    Gottsauner-Wolf, F
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2001, 139 (03): : 194 - 199
  • [7] THE ACETABULAR CONVEXITY AS A SPECIFIC ADDITION IN TOTAL HIP REPLACEMENTS
    GLEISSNER, F
    WESSINGHAGE, D
    FITZEK, JG
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1991, 129 (02): : 188 - 193
  • [8] HAAKER R, 2002, NAVIGATION ROBOTIK G
  • [9] HAAKER R, 2001, BIOCERAMICS JOINT AR, P18
  • [10] HAAKER R, 2002, IN PRESS SCHRAUBPFAN