Aortic remodeling after hybrid provisional extension to induce complete attachment aortic repair of chronic residual type I aortic dissection

被引:14
作者
Huang, Chun-Yang [1 ,2 ]
Hsu, Hung-Lung [2 ,3 ]
Chen, Po-Lin [1 ,2 ]
Kuo, Tzu-Ting [1 ,2 ]
Chen, I-Ming [1 ,2 ]
Hsu, Chiao-Po [1 ,2 ]
Shih, Chun-Che [1 ,2 ]
机构
[1] Taipei Vet Gen Hosp, Div Cardiovasc Surg, Dept Surg, Taipei, Taiwan
[2] Natl Yang Ming Univ, Inst Clin Med, Sch Med, Taipei, Taiwan
[3] Far Eastern Mem Hosp, Div Cardiovasc Surg, Taipei, Taiwan
关键词
aortic dissection; aortic remodeling; bare metal stent; PETTICOAT; residual aortic dissection; FALSE LUMEN; ENDOVASCULAR TREATMENT; DEVICE; VOLUME; ENTRY; ENLARGEMENT; MANAGEMENT; THROMBOSIS; ANEURYSM; TEARS;
D O I
10.1016/j.jtcvs.2018.12.041
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Our objective was to examine the role of the provisional extension to induce complete attachment (PETTICOAT) aortic dissection repair technique with bare metal stents (BMSs) in abdominal remodeling of residual DeBakey type I aortic dissection. Methods: We retrospectively reviewed the records of patients with chronic aneurysm formation and residual DeBakey type I aortic dissection (ie, original acute aortic dissection DeBakey type I after primary surgical open repair) who underwent arch reoperation with frozen elephant trunk replacement or endovascular debranching with or without an abdominal BMS between December 2006 and December 2016. We analyzed diameters and volumes in 3 dimensions for the true and false lumens of the thoracic and abdominal aorta as well as the thrombosis percentage of the false lumen between the non-BMS (non-PETTICOAT) and BMS (PETTICOAT) groups. Results: Forty-seven patients who had completed at least 1 year of follow-up were included. The non-BMS (without abdominal BMS) and BMS groups had significant differences in abdominal true lumen diameter and volumetric change at the first postoperative examination and at the examination 1 year after surgery (26.8 mL, median [19.4-34.1 mL, interquartile range (IQR)]) in non-BMS vs 42.5 mL, median [31.1-57.9 mL, IQR]) in BMS (postoperative survey [F test, 33.775; P = .000]) and (30.1 mL, median [20.5-34.1 mL, IQR] in non-BMS vs 46.6 mL, median [31.3-57.4 mL, IQR]) in BMS (12-month survey [F test, 14.001; P = .001]). The abdominal false lumen thrombosis percentage was higher in the BMS group than in the non-BMS group (25.6%, median [16.4%-58.9%, IQR] in non-BMS vs 54.0%, median [36.7%-65.3%, IQR] in the BMS group (F test, 6.318; P = .016). Conclusions: Following reintervention for chronic residual DeBakey type I aortic dissection, PETTICOAT abdominal dissection BMS effectively expanded the thoracic and abdominal true lumen and augmented false lumen thrombosis percentage during the first postoperative year.
引用
收藏
页码:1007 / 1016
页数:10
相关论文
共 25 条
[11]   Distribution of intimomedial tears in patients with type B aortic dissection [J].
Khoynezhad, Ali ;
Walot, Irwin ;
Kruse, Matthew J. ;
Rapae, Tony ;
Donayre, Carlos E. ;
White, Rodney A. .
JOURNAL OF VASCULAR SURGERY, 2010, 52 (03) :562-568
[12]   False Lumen Status in Patients With Acute Aortic Dissection: A Systematic Review and Meta-Analysis [J].
Li, Dongze ;
Ye, Lei ;
He, Yarong ;
Cao, Xiaoping ;
Liu, Jining ;
Zhong, Wu ;
Cao, Linghong ;
Zeng, Rui ;
Zeng, Zhi ;
Wan, Zhi ;
Cao, Yu .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (05)
[13]   Preoperative thoracic false lumen branches are predictors of aortic enlargement after stent grafting for DeBakey IIIb aortic dissection [J].
Liu, Feng ;
Ge, Yang Yang ;
Guo, Wei ;
Liu, Xiao Ping ;
Jia, Xin ;
Xiong, Jiang ;
Ma, Xiao Hui .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (01) :21-+
[14]   Aortic remodeling after endovascular treatment of complicated type B aortic dissection with the use of a composite device design [J].
Lombardi, Joseph V. ;
Cambria, Richard P. ;
Nienaber, Christoph A. ;
Chiesa, Roberto ;
Mossop, Peter ;
Haulon, Stephan ;
Zhou, Qing ;
Jia, Feiyi .
JOURNAL OF VASCULAR SURGERY, 2014, 59 (06) :1544-1554
[15]   Prospective multicenter clinical trial (STABLE) on the endovascular treatment of complicated type B aortic dissection using a composite device design [J].
Lombardi, Joseph V. ;
Cambria, Richard P. ;
Nienaber, Christoph A. ;
Chiesa, Roberto ;
Teebken, Omke ;
Lee, Anthony ;
Mossop, Peter ;
Bharadwaj, Priya .
JOURNAL OF VASCULAR SURGERY, 2012, 55 (03) :629-U319
[16]   Volume changes in aortic true and false lumen after the "PETTICOAT" procedure for type B aortic dissection [J].
Melissano, Germano ;
Bertoglio, Luca ;
Rinaldi, Enrico ;
Civilini, Efrem ;
Tshomba, Yamume ;
Kahlberg, Andrea ;
Agricola, Eustachio ;
Chiesa, Roberto .
JOURNAL OF VASCULAR SURGERY, 2012, 55 (03) :641-651
[17]   Risk factors of incomplete thrombosis in the false lumen after endovascular treatment of extensive acute type B aortic dissection [J].
Qin, Yong-Lin ;
Deng, Gang ;
Li, Tian-Xiao ;
Jing, Rui-Wei ;
Teng, Gao-Jun .
JOURNAL OF VASCULAR SURGERY, 2012, 56 (05) :1232-1238
[18]  
Quint LE, 2003, J ENDOVASC THER, V10, P505, DOI 10.1583/1545-1550(2003)010<0505:AITDWS>2.0.CO
[19]  
2
[20]   Volume analysis of true and false lumens in acute complicated type B aortic dissections after thoracic endovascular aortic repair with stent grafts alone or with a composite device design [J].
Sobocinski, Jonathan ;
Lombardi, Joseph V. ;
Dias, Nuno V. ;
Berger, Ludovic ;
Zhou, Qing ;
Jia, Feiyi ;
Resch, Timothy ;
Haulon, Stephan .
JOURNAL OF VASCULAR SURGERY, 2016, 63 (05) :1216-1224