Global Spectral Deconvolution Based on Non-Negative Matrix Factorization in GC x GC-HRTOFMS

被引:20
作者
Zushi, Yasuyuki [1 ]
Hashimoto, Shunji [1 ]
Tanabe, Kiyoshi [1 ]
机构
[1] Natl Inst Environm Studies, Ctr Environm Measurement & Anal, Tsukuba, Ibaraki 3058506, Japan
关键词
2-DIMENSIONAL GAS-CHROMATOGRAPHY; FLIGHT MASS-SPECTROMETRY; INDEPENDENT COMPONENT ANALYSIS; RESOLUTION; IDENTIFICATION; QUANTIFICATION; DECOMPOSITION; EXTRACTION; PARAFAC; SAMPLES;
D O I
10.1021/ac5038544
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A global spectral deconvolution, based on non-negative matrix factorization (NMF) in comprehensive two-dimensional gas chromatography high-resolution time-of-flight mass spectrometry, was developed. We evaluated the ability of various instrumental parameters and NMF settings to derive high-performance detection in nontarget screening using a sediment sample. To evaluate the performance of the process, a NIST library search was used to identify the deconvoluted spectra. Differences of the instrumental scan rates (25 and 50 Hz) in deconvolution were evaluated and results show that a high scan rate enhanced the number of compounds detected in the sediment sample. A higher mass resolution in the range of 1 000 to 10 000 and a higher m/z precision in the deconvolution were needed to obtain an accurate mass database. After removal of multiple duplicate hits, which occurred in batch processes of NIST library search on the deconvolution result, 62 unique assignable spectra with a match factor >= 900 were obtained in the deconvoluted chromatogram from the sediment sample, including 54 spectra that were refined by the deconvolution. This method will help to detect and build up well-resolved reference spectra from various complex mixtures and will accelerate nontarget screening.
引用
收藏
页码:1829 / 1838
页数:10
相关论文
共 35 条
[1]  
[Anonymous], 1970, UCLA WORK PAP PHONET
[2]   INDEPENDENT COMPONENT ANALYSIS, A NEW CONCEPT [J].
COMON, P .
SIGNAL PROCESSING, 1994, 36 (03) :287-314
[3]  
de Frein R., 2008, Proc. Int. Mathematical Forum, V3, P1853
[4]   A novel trilinear decomposition algorithm: Three-dimension non-negative matrix factorization [J].
Gao, Hong Tao ;
Dai, Dong Mei ;
Li, Tong Hua .
CHINESE CHEMICAL LETTERS, 2007, 18 (04) :495-498
[5]   Overlapping spectra resolution using non-negative matrix factorization [J].
Gao, HT ;
Li, TH ;
Chen, K ;
Li, WG ;
Bi, X .
TALANTA, 2005, 66 (01) :65-73
[6]   A flexible R package for nonnegative matrix factorization [J].
Gaujoux, Renaud ;
Seoighe, Cathal .
BMC BIOINFORMATICS, 2010, 11
[7]   Selective extraction of halogenated compounds from data measured by comprehensive multidimensional gas chromatography/high resolution time-of-flight mass spectrometry for non-target analysis of environmental and biological samples [J].
Hashimoto, Shunji ;
Zushi, Yasuyuki ;
Fushimi, Akihiro ;
Takazawa, Yoshikatsu ;
Tanabe, Kiyoshi ;
Shibata, Yasuyuki .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1282 :183-189
[8]   Global and selective detection of organohalogens in environmental samples by comprehensive two-dimensional gas chromatography-tandem mass spectrometry and high-resolution time-of-flight mass spectrometry [J].
Hashimoto, Shunji ;
Takazawa, Yoshikatsu ;
Fushimi, Akihiro ;
Tanabe, Kiyoshi ;
Shibata, Yasuyuki ;
Ieda, Teruyo ;
Ochiai, Nobuo ;
Kanda, Hirooki ;
Ohura, Takeshi ;
Tao, Qingping ;
Reichenbach, Stephen E. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (24) :3799-3810
[9]   Parallel factor analysis (PARAFAC) of target analytes in GC x GC-TOFMS data: Automated selection of a model with an appropriate number of factors [J].
Hoggard, Jamin C. ;
Synovec, Robert E. .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1611-1619
[10]   Toward automated peak resolution in complete GC x GC-TOFMS chromatograms by PARAFAC [J].
Hoggard, Jamin C. ;
Siegler, W. Christopher ;
Synovec, Robert E. .
JOURNAL OF CHEMOMETRICS, 2009, 23 (7-8) :421-431