Analysis on Interruption and Plane Layout of Shear Wall for Frame-shear Wall Structure with Top Fault Shear Wall

被引:0
|
作者
Qin Li [1 ]
Xu Ang [1 ]
Du Qi-shou [1 ]
机构
[1] NE Dianli Univ, Sch Architectural & Civil Engn, Changchun, Jilin, Peoples R China
来源
2009 INTERNATIONAL CONFERENCE ON INFORMATION MANAGEMENT, INNOVATION MANAGEMENT AND INDUSTRIAL ENGINEERING, VOL 2, PROCEEDINGS | 2009年
关键词
frame-shear wall structure; top fault shear wall; interruptable position; Style Box; shear wall interrupted ratio;
D O I
10.1109/ICIII.2009.236
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
According to the force-deformation characteristics of frame-shear wall structure, the calculation and analysis model of the "Style Box" type layout of frame-shear wall structure is advanced with the basic and simple arrangement of frame- shear wall structure. The different plane and vertical layout with interrupting shear walls of the frame-shear wall structure with top fault shear walls is discussed primarily by using the method of plane layout and vertical interruptable position being considered at the same time. Based on the main parameters of the frame-shear wall structure with top fault shear walls in different ways, it puts forward the importance of the shear wall location of the plane layout to the overall performance of the frame-shear wall structure with top fault shear walls except the lateral stiffness of the shear wall corresponding to the shear wall interrupted ratio.
引用
收藏
页码:328 / 331
页数:4
相关论文
共 50 条
  • [41] Seismic performance of RC frame-shear wall structures with vertical setback
    Jiang, Huanjun
    Huang, Youlu
    He, Liusheng
    Huang, Tian
    Zhang, Shaojing
    STRUCTURES, 2021, 33 : 4203 - 4217
  • [42] Study of seismic earthquake for frame-shear wall structures under earthquake
    Liu, Yan-Hui
    Tan, Ping
    Zhou, Fu-Lin
    Du, Yong-Feng
    Yan, Wei-Ming
    Sichuan Daxue Xuebao (Gongcheng Kexue Ban)/Journal of Sichuan University (Engineering Science Edition), 2011, 43 (05): : 32 - 38
  • [43] Monitoring the inner force of the frame-shear wall structure with MR dampers by FBG sensors
    Li, Xiuling
    ADVANCES IN STRUCTURAL ENGINEERING, PTS 1-3, 2011, 94-96 : 1031 - 1035
  • [44] Pseudo-Dynamic Tests on Frame-Shear Wall Structure with Precast Concrete Diaphragm
    Han, Chun
    Dong, Xinhong
    Su, Qunshan
    Duan, Chunming
    Tian, Guoping
    BUILDINGS, 2024, 14 (04)
  • [45] Forecasting seismic damage in frame-shear wall structure based on fuzzy neural network
    Jiang, Wei
    Gu, Bing Xin
    ADVANCES IN INDUSTRIAL AND CIVIL ENGINEERING, PTS 1-4, 2012, 594-597 : 1692 - 1695
  • [46] A simple formulation for free vibration of frame-shear wall tall building
    Wang, QF
    Wang, LY
    ADVANCES IN STEEL STRUCTURES, VOLS 1 AND 2, 1999, : 889 - 895
  • [47] Cyclic Tests and Simulations of Spatial RC Frame-Shear Wall Structures
    Huang, Shixiang
    Zhao, Xinyu
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 1569 - 1573
  • [48] ANALYSIS OF SHEAR WALL BUILDINGS BY FRAME METHOD
    MACLEOD, IA
    LIAUW, TC
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 2-RESEARCH AND THEORY, 1974, 57 (MAR): : 179 - 182
  • [49] FRAME ANALYSIS OF SHEAR WALL CORES - DISCUSSION
    DESCHAPELLES, B
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1978, 104 (09): : 1542 - 1544
  • [50] GENERAL FRAME ELEMENT FOR SHEAR WALL ANALYSIS
    MACLEOD, IA
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 2-RESEARCH AND THEORY, 1976, 61 (DEC): : 785 - 790