Effect of Implantation Accuracy on Ankle Contact Mechanics with a Metallic Focal Resurfacing Implant

被引:35
作者
Anderson, Donald D. [1 ]
Tochigi, Yuki [1 ]
Rudert, James [1 ]
Vaseenon, Tanawat [1 ]
Brown, Thomas D. [1 ]
Amendola, Annunziato [1 ]
机构
[1] Univ Iowa, Orthopaed Biomech Lab, Dept Orthopaed & Rehabil, Iowa City, IA 52242 USA
基金
美国国家卫生研究院;
关键词
FULL-THICKNESS DEFECTS; ARTICULAR-CARTILAGE; OSTEOCHONDRAL TRANSPLANTATION; STRESS RATES; JOINT; PRESSURE; TALUS; INSTABILITY; AREA; MOSAICPLASTY;
D O I
10.2106/JBJS.I.00431
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Talar osteochondral defects can lead to joint degeneration. Focal resurfacing with a metallic implant has shown promise in other joints. We studied the effect of implantation accuracy on ankle contact mechanics after focal resurfacing of a defect in the talar dome. Methods: Static loading of seven cadaver ankles was performed before and after creation of a 15-mm-diameter osteochondral defect on the talar dome, and joint contact stresses were measured. The defect was then resurfaced with a metallic implant, with use of a custom implant-bone interface fixture that allowed fine control (in 0.25-mm steps) of implantation height. Stress measurements were repeated at heights of -0.5 to +0.5 mm relative to an as-implanted reference. Finite element analysis was used to determine the effect of implant height, post axis rotation, and valgus/varus tilt over a motion duty cycle. Results: With the untreated defect, there was a 20% reduction in contact area and a 40% increase in peak contact stress, as well as a shift in the location of the most highly loaded region, as compared with the values in the intact condition. Resurfacing led to recovery of 90% of the contact area that had been measured in the intact specimen, but the peak contact stresses remained elevated. With the implant 0.25 mm proud, peak contact stress was 220% of that in the intact specimen. The results of the finite element analyses agreed closely with those of the experiments and additionally showed substantial variations in defect influences on contact stresses across the motion arc. Talar internal/external rotations also differed for the unfilled defect. Focal implant resurfacing substantially restored kinematics but did not restore the stresses to the levels in the intact specimens. Conclusions: Focal resurfacing with a metallic implant appears to have the potential to restore normal joint mechanics in ankles with a large talar osteochondral defect. However, contact stresses were found to be highly sensitive to implant positioning.
引用
收藏
页码:1490 / 1500
页数:11
相关论文
共 53 条
[1]   Intra-articular contact stress distributions at the ankle throughout stance phase-patient-specific finite element analysis as a metric of degeneration propensity [J].
Anderson, Donald D. ;
Goldsworthy, Jane K. ;
Shivanna, Kiran ;
Grosland, Nicole M. ;
Pedersen, Douglas R. ;
Thomas, Thaddeus P. ;
Tochigi, Yuki ;
Marsh, J. Lawrence ;
Brown, Thomas D. .
BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2006, 5 (2-3) :82-89
[2]   Autologous chondrocyte transplantation for treating cartilage defects of the talus [J].
Baums, MH ;
Heidrich, G ;
Schultz, W ;
Steckel, H ;
Kahl, E ;
Klinger, HM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (02) :303-308
[3]   Effects of a contoured articular prosthetic device on tibiofemoral peak contact pressure: a biomechanical study [J].
Becher, Christoph ;
Huber, Roland ;
Thermann, Hajo ;
Paessler, Hans H. ;
Skrbensky, Gobert .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (01) :56-63
[4]   New methods for assessing cartilage contact stress after articular fracture [J].
Brown, TD ;
Rudert, MJ ;
Grosland, NM .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (423) :52-58
[5]  
Cannon Anthony, 2008, Iowa Orthop J, V28, P42
[6]   Articular damage caused by metal plugs in a rabbit model for treatment of localized cartilage defects [J].
Clusters, R. J. H. ;
Dhert, W. J. A. ;
van Rijen, M. H. P. ;
Verbout, A. J. ;
Creemers, L. B. ;
Saris, D. B. F. .
OSTEOARTHRITIS AND CARTILAGE, 2007, 15 (08) :937-945
[7]   Articular Cartilage Degeneration Following the Treatment of Focal Cartilage Defects with Ceramic Metal Implants and Compared with Microfracture [J].
Custers, R. J. H. ;
Saris, D. B. F. ;
Dhert, W. J. A. ;
Verbout, A. J. ;
van Rijen, M. H. P. ;
Mastbergen, S. C. ;
Lafeber, F. P. J. G. ;
Creemers, L. B. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (04) :900-910
[8]   Cartilage Damage Caused by Metal Implants Applied for the Treatment of Established Localized Cartilage Defects in a Rabbit Model [J].
Custers, Roel J. H. ;
Creemers, Laura B. ;
van Rijen, Mattie H. P. ;
Verbout, Ab J. ;
Saris, Daniel B. F. ;
Dhert, Wouter J. A. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2009, 27 (01) :84-90
[9]   Focal anatomic patellofemoral inlay resurfacing: Theoretic basis, surgical technique, and case reports [J].
Davidson, Philip A. ;
Rivenburgh, Dennis .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2008, 39 (03) :337-+
[10]   CONTACT CHARACTERISTICS OF THE ANKLE JOINT .1. THE NORMAL JOINT [J].
DRISCOLL, HL ;
CHRISTENSEN, JC ;
TENCER, AF .
JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 1994, 84 (10) :491-498