Comparative performance of air-conditioning systems with different refrigerant circuitries in liquid-separation condenser

被引:18
作者
Chen, Jianyong [1 ,2 ]
Li, Yunhai [1 ]
Ding, Rong [1 ]
Lin, Xu [1 ]
Chen, Ying [1 ,2 ]
Luo, Xianglong [1 ,2 ]
Yang, Zhi [1 ,2 ]
机构
[1] Guangdong Univ Technol, Sch Mat & Energy, Guangzhou 510006, Guangdong, Peoples R China
[2] Guangdong Prov Key Lab Funct Soft Condensed Matte, Guangzhou 510006, Guangdong, Peoples R China
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2018年 / 92卷
基金
中国国家自然科学基金;
关键词
Liquid-separation condenser; Air-conditioning system; Refrigerant circuitry; Performance; Exergy analysis; EXERGY ANALYSIS; THERMODYNAMIC PERFORMANCE; HEAT-EXCHANGERS; TUBE CONDENSER; VAPOR; ENERGY; ARRANGEMENT; R1234YF; R134A; DROP;
D O I
10.1016/j.ijrefrig.2018.05.031
中图分类号
O414.1 [热力学];
学科分类号
摘要
Liquid-separation condensation is a novel technology to enhance the condenser performance. Four liquid-separation condensers (LSCs) that had the only difference in refrigerant circuitry were designed, and they were respectively installed to the air-conditioning system and experimentally studied. The capillary tube length and the refrigerant charge were adjusted to achieve the optimum energy efficiency ratio (EER) for each system. The cooling capacity, the system power input and EER were compared at the optimum point. It is found that the four systems are most distinguished in LSCs in terms of condensing pressure and subcooling because of different refrigerant circuitries. The exergy analysis was also carried out. The results show that the refrigerant circuity in LSC has great impacts on the exergetic performance of all system components, and the order of highest exergy efficiency of the four systems is different from that of EER. The detailed characteristics of the four LSCs were further discussed at the designing condition and the practical condition in the tests. The pressure drop of LSC is dominated by the last pass that has serpentine tubes. It is concluded that a low penalty factor (PF) in LSC does not guarantee the good system performance. The optimization of refrigerant circuitry in the condenser to improve the system efficiency should use the system performance as the objective at the system level instead of PF. (C) 2018 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:154 / 164
页数:11
相关论文
共 29 条
[1]  
[Anonymous], 1987, MONTREAL PROTOCOL SU
[2]  
AQSIQ (General Administration of Quality Supervision Inspection and Quarantine of the People's Republic of China, 2004, 77252004 GBT AQSIQ
[3]   Energy and exergy analysis of R1234yf as drop-in replacement for R134a in a domestic refrigeration system [J].
Belman-Flores, J. M. ;
Rangel-Hernandez, V. H. ;
Uson, S. ;
Rubio-Maya, C. .
ENERGY, 2017, 132 :116-125
[4]   In-tube condensation performance of refrigerants considering penalization terms (exergy losses) for heat transfer and pressure drop [J].
Cavallini, Alberto ;
Brown, J. Steven ;
Del Col, Davide ;
Zilio, Claudio .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (13-14) :2885-2896
[5]   Evaluation of the ejector refrigeration system with environmentally friendly working fluids from energy, conventional exergy and advanced exergy perspectives [J].
Chen, Jianyong ;
Zhu, Kangda ;
Huang, Yisheng ;
Chen, Ying ;
Luo, Xianglong .
ENERGY CONVERSION AND MANAGEMENT, 2017, 148 :1208-1224
[6]   Exceeding the limit of plasmonic light trapping in textured screen-printed solar cells using Al nanoparticles and wrinkle-like graphene sheets [J].
Chen, Xi ;
Jia, Baohua ;
Zhang, Yinan ;
Gu, Min .
LIGHT-SCIENCE & APPLICATIONS, 2013, 2 :e92-e92
[7]   Performances of a split-type air conditioner employing a condenser with liquid-vapor separation baffles [J].
Chen, Y. ;
Hua, N. ;
Deng, L. S. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (02) :278-289
[8]   Energy and Exergy Analysis on a Parallel-Flow Condenser With Liquid-Vapor Separators in an R22 Residential Air-Conditioning System [J].
Chen, Ying ;
Deng, Lisheng ;
Mo, Songping ;
Luo, Xianglong .
HEAT TRANSFER ENGINEERING, 2015, 36 (01) :102-112
[9]   Optimization of finned-tube condensers using an intelligent system [J].
Domanski, Piotr A. ;
Yashar, David .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (03) :482-488
[10]   Experimental investigation of double-pipe heat exchangers in air conditioning applications [J].
Ghani, Saud ;
Gamaledin, Seifelislam Mahmoud Ahmad ;
Rashwan, Mohammed Mohammed ;
Atieh, Muataz Ali .
ENERGY AND BUILDINGS, 2018, 158 :801-811