Tunnel probes for measurements of the electron and ion temperature in fusion plasmas

被引:19
作者
Gunn, JP [1 ]
Schrittwieser, R
Balan, P
Ionita, C
Stöckel, J
Adámek, J
Duran, I
Hron, M
Pánek, R
Barina, O
Hrach, R
Vicher, M
Van Oost, G
Van Rompuy, T
Martines, E
机构
[1] EURATOM, CEA Fus Controlee, St Paul Les Durance, France
[2] Univ Innsbruck, Dept Ion Phys, A-6020 Innsbruck, Austria
[3] Assoc EURATOM IPP CR, Inst Plasma Phys, Prague, Czech Republic
[4] Charles Univ Prague, Fac Math & Phys, Prague, Czech Republic
[5] Univ Ghent, Dept Appl Phys, B-9000 Ghent, Belgium
[6] EURATOM, ENEA Fus, Consorzio RFX, Padua, Italy
关键词
D O I
10.1063/1.1787581
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed tunnel probes for localized measurements of the electron and ion temperature in the edge plasma region of smaller tokamaks and stellarators. A normal tunnel probe for T-e measurements consists of a metallic tunnel of 5 mm diameter and 5 mm length, with the axis parallel to the magnetic field. One side is open, the other side is closed by a metallic backplate, isolated from the tunnel. If both electrodes are biased negatively, ions flow into the office, and their current is distributed between the tunnel and the backplate. The ratio of the two ion currents is a function of T-e. With an additional diaphragm in front of the orifice, the probe becomes ion sensitive, since the electrons are prevented from the tunnel because of their smaller gyroradius, but ions can still reach it. In this way, the perpendicular ion temperature can be derived. By segmenting the tunnel axially into two parts, also an approximate measure for the parallel ion temperature can be found. (C) 2004 American Institute of Physics.
引用
收藏
页码:4328 / 4330
页数:3
相关论文
共 8 条
  • [1] The influence of magnetization strength on the sheath: Implications for flush-mounted probes
    Gunn, JP
    [J]. PHYSICS OF PLASMAS, 1997, 4 (12) : 4435 - 4446
  • [2] A DC probe diagnostics for fast electron temperature measurements in tokamak edge plasmas
    Gunn, JP
    Devynck, P
    Pascal, JY
    Adámek, J
    Duran, I
    Hron, M
    Stöckel, J
    Zácek, F
    Barina, O
    Hrach, R
    Vicher, M
    Van Oost, G
    [J]. CZECHOSLOVAK JOURNAL OF PHYSICS, 2002, 52 (10) : 1107 - 1114
  • [3] Magnetized plasma flow through a small orifice
    Gunn, JP
    [J]. PHYSICS OF PLASMAS, 2001, 8 (03) : 1040 - 1047
  • [4] ION SENSITIVE PROBE - A NEW DIAGNOSTIC METHOD FOR PLASMA IN MAGNETIC FIELDS
    KATSUMATA, I
    OKAZAKI, M
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 1967, 6 (01) : 123 - +
  • [5] Katsumata I., 1996, CONTRIB PLASM PHYS, V36 S, P73, DOI DOI 10.1002/CTPP.19960360112
  • [6] Direct measurement of ion behavior using modified ion sensitive probe in tokamak boundary plasma
    Uehara, K
    Tsushima, A
    Amemiya, H
    [J]. JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1997, 66 (04) : 921 - 924
  • [7] Van Oost G, 2003, PLASMA PHYS CONTR F, V45, P621, DOI 10.1088/0741-3335/45/5/308
  • [8] AN OBJECT-ORIENTED ELECTROMAGNETIC PIC CODE
    VERBONCOEUR, JP
    LANGDON, AB
    GLADD, NT
    [J]. COMPUTER PHYSICS COMMUNICATIONS, 1995, 87 (1-2) : 199 - 211