Thermal comfort conditions at the platforms of the Athens Metro

被引:15
作者
Assimakopoulos, Margarita N. [1 ]
Katavoutas, George [1 ]
机构
[1] Univ Athens, Fac Phys, Dept Environm Phys Meteorol, Univ Campus, Athens 15784, Greece
来源
INTERNATIONAL HIGH-PERFORMANCE BUILT ENVIRONMENT CONFERENCE - A SUSTAINABLE BUILT ENVIRONMENT CONFERENCE 2016 SERIES (SBE16), IHBE 2016 | 2017年 / 180卷
关键词
Human exposure; subway platforms; passengers' thermal comfort; INDOOR AIR-QUALITY; SEOUL METROPOLITAN SUBWAY; UNDERGROUND RAILWAY; PARTICULATE MATTER; ENVIRONMENT; SYSTEMS;
D O I
10.1016/j.proeng.2017.04.252
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The current study aims at the comparison of the field measurements at the platforms of the Athens Metro with those recommended by international standard thermal comfort and to the investigation of the relationship of environmental parameters between platforms and the outdoor space. The levels of air, operative and globe temperature as well as air humidity and air velocity were continuously monitored at the platform space of two stations with different depth and design features in summer. The predicted mean vote (PMV) model and the predicted percentage of dissatisfied (PPD) index were used. The results reveal that the operative temperature at both stations is far from the traditional still-air comfort zones. For the case of elevated air movement of 1.2 ms(-1) and considering the occupants have local control of air speed, 20.3% of the values at the station with the greatest depth do not exceed the upper limit. Furthermore, 64% of the variation in air temperature at the platform of the station with the smallest depth is explained by outdoor air temperature, while the corresponding percentage for the station with the greatest depth is 29%. Passengers experience sudden change of air temperature and PMV, especially at the station with the smallest depth, during their transition from the platform to the interior of air-conditioned train carriages and vice versa. (c) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:925 / 931
页数:7
相关论文
共 23 条
[21]  
Ordody P., 2000, PERIODICA POLYTECHNI, V44, P309
[22]  
Triandis E.S., 2007, P 11 ACUUS INT C UND, P249
[23]   Investigation of indoor environmental quality in Shanghai metro stations, China [J].
Ye, Xiaojiang ;
Lian, Zhiwei ;
Jiang, Chunxiao ;
Zhou, Zhaoxia ;
Chen, Huanxin .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2010, 167 (1-4) :643-651