Recommended Implementation of Arterial Spin-Labeled Perfusion MRI for Clinical Applications: A Consensus of the ISMRM Perfusion Study Group and the European Consortium for ASL in Dementia

被引:1694
作者
Alsop, David C. [1 ,2 ]
Detre, John A. [3 ,4 ]
Golay, Xavier [5 ]
Guenther, Matthias [6 ,7 ,8 ]
Hendrikse, Jeroen [9 ]
Hernandez-Garcia, Luis [10 ]
Lu, Hanzhang [11 ]
MacIntosh, Bradley J. [12 ,13 ]
Parkes, Laura M. [14 ]
Smits, Marion [15 ]
van Osch, Matthias J. P. [16 ]
Wang, Danny J. J. [17 ]
Wong, Eric C. [18 ,19 ]
Zaharchuk, Greg [20 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Univ Penn, Dept Neurol, Philadelphia, PA 19104 USA
[4] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[5] UCL Inst Neurol, Dept Brain Repair & Rehabil, London, England
[6] Fraunhofer MEVIS, Bremen, Germany
[7] Univ Bremen, D-28359 Bremen, Germany
[8] Mediri GmbH, Heidelberg, Germany
[9] Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
[10] Univ Michigan, Dept Biomed Engn, FMRI Lab, Ann Arbor, MI 48109 USA
[11] UT Southwestern Med Ctr, Adv Imaging Res Ctr, Dallas, TX USA
[12] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[13] Sunnybrook Res Inst, Dept Phys Sci, Toronto, ON, Canada
[14] Univ Manchester, Ctr Imaging Sci, Inst Populat Hlth, Fac Med & Human Sci, Manchester, Lancs, England
[15] Univ Med Ctr Rotterdam, Erasmus MC, Dept Radiol, Rotterdam, Netherlands
[16] Leiden Univ, Med Ctr, Dept Radiol, CJ Gorter Ctr High Field MRI, Leiden, Netherlands
[17] Univ Calif Los Angeles, Dept Neurol, Los Angeles, CA 90024 USA
[18] Univ Calif San Diego, Dept Radiol, La Jolla, CA 92093 USA
[19] Univ Calif San Diego, Dept Psychiat, La Jolla, CA 92093 USA
[20] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
基金
英国工程与自然科学研究理事会;
关键词
arterial spin labeling; perfusion; cerebral blood flow; ACUTE ISCHEMIC-STROKE; BLOOD PARTITION-COEFFICIENT; TRANSIT-TIME CHANGES; CEREBRAL PERFUSION; IMAGING TECHNIQUES; INVERSION; QUANTIFICATION; SENSITIVITY; EFFICIENCY; SIGNAL;
D O I
10.1002/mrm.25197
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This review provides a summary statement of recommended implementations of arterial spin labeling (ASL) for clinical applications. It is a consensus of the ISMRM Perfusion Study Group and the European ASL in Dementia consortium, both of whom met to reach this consensus in October 2012 in Amsterdam. Although ASL continues to undergo rapid technical development, we believe that current ASL methods are robust and ready to provide useful clinical information, and that a consensus statement on recommended implementations will help the clinical community to adopt a standardized approach. In this review, we describe the major considerations and trade-offs in implementing an ASL protocol and provide specific recommendations for a standard approach. Our conclusion is that as an optimal default implementation, we recommend pseudo-continuous labeling, background suppression, a segmented three-dimensional readout without vascular crushing gradients, and calculation and presentation of both label/control difference images and cerebral blood flow in absolute units using a simplified model. Magn Reson Med 73:102-116, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:102 / 116
页数:15
相关论文
共 79 条
[1]   Multisection cerebral blood flow MR imaging with continuous arterial spin labeling [J].
Alsop, DC ;
Detre, JA .
RADIOLOGY, 1998, 208 (02) :410-416
[2]   Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow [J].
Alsop, DC ;
Detre, JA .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (06) :1236-1249
[3]  
[Anonymous], [No title captured]
[4]   Estimation of Labeling Efficiency in Pseudocontinuous Arterial Spin Labeling [J].
Aslan, Sina ;
Xu, Feng ;
Wang, Peiying L. ;
Uh, Jinsoo ;
Yezhuvath, Uma S. ;
van Osch, Matthias ;
Lu, Hanzhang .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) :765-771
[5]   Noninvasive MR imaging of cerebral perfusion in patients with a carotid artery stenosis [J].
Bokkers, R. P. H. ;
van der Worp, H. B. ;
Mali, W. P. T. M. ;
Hendrikse, J. .
NEUROLOGY, 2009, 73 (11) :869-875
[6]   Whole-Brain Arterial Spin Labeling Perfusion MRI in Patients With Acute Stroke [J].
Bokkers, Reinoud P. H. ;
Hernandez, Daymara A. ;
Merino, Jose G. ;
Mirasol, Raymond V. ;
van Osch, Matthias J. ;
Hendrikse, Jeroen ;
Warach, Steven ;
Latour, Lawrence L. .
STROKE, 2012, 43 (05) :1290-1294
[7]   Arterial spin labeling perfusion MRI at multiple delay times: a correlative study with H215O positron emission tomography in patients with symptomatic carotid artery occlusion [J].
Bokkers, Reinoud P. H. ;
Bremmer, Jochem P. ;
van Berckel, Bart N. M. ;
Lammertsma, Adriaan A. ;
Hendrikse, Jeroen ;
Pluim, Josien P. W. ;
Kappelle, L. Jaap ;
Boellaard, Ronald ;
Klijn, Catharina J. M. .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2010, 30 (01) :222-229
[8]   A general kinetic model for quantitative perfusion imaging with arterial spin labeling [J].
Buxton, RB ;
Frank, LR ;
Wong, EC ;
Siewert, B ;
Warach, S ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) :383-396
[9]   Magnetic resonance perfusion imaging in acute ischemic stroke using continuous arterial spin labeling [J].
Chalela, JA ;
Alsop, DC ;
Gonzalez-Atavales, JB ;
Maldjian, JA ;
Kasner, SE ;
Detre, JA .
STROKE, 2000, 31 (03) :680-687
[10]   Test-Retest Reliability of Arterial Spin Labeling With Common Labeling Strategies [J].
Chen, Yufen ;
Wang, Danny J. J. ;
Detre, John A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) :940-949