Thrombocytopenia After Aortic Valve Replacement With Freedom Solo Bioprosthesis: A Propensity Study

被引:35
|
作者
Piccardo, Alessandro
Rusinaru, Dan
Petitprez, Benoit
Marticho, Paul
Vaida, Ioana
Tribouilloy, Christophe
Caus, Thierry
机构
[1] Amiens Picardie Univ Hosp, Dept Cardiac Surg, Amiens, France
[2] Amiens Picardie Univ Hosp, Dept Hematol, Amiens, France
[3] Amiens Picardie Univ Hosp, Dept Cardiol, Amiens, France
来源
ANNALS OF THORACIC SURGERY | 2010年 / 89卷 / 05期
关键词
DIAGNOSIS;
D O I
10.1016/j.athoracsur.2010.01.040
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The incidence of postoperative thrombocytopenia after aortic valve replacement with the Freedom Solo bioprosthesis remains unclear. This propensity-matched study was carried out to evaluate the incidence and clinical impact of thrombocytopenia in patients receiving the Freedom Solo bioprosthesis. Methods. Patients who underwent aortic valve replacement with a Freedom Solo or Carpentier-Edwards Perimount pericardial prosthesis at our institution between 2006 and 2008 were screened retrospectively. Exclusion criteria included double valve replacement, redo surgery, and active endocarditis. Two hundred six patients were considered eligible for this analysis. Using propensity scores 36 matched pairs of patients with a Freedom Solo or Perimount bioprosthesis were obtained. The primary end point was the occurrence of postoperative thrombocytopenia. Secondary end points were postoperative thromboembolic or hemorrhagic events and 30-day mortality. Results. Before matching, severe thrombocytopenia (<30 x 10(9) platelets/L) occurred in 22% of patients with a Freedom Solo bioprosthesis and 1% with a Perimount bioprosthesis (p < 0.0001), thromboembolic or hemorrhagic events occurred in 3% and 2%, respectively (p = 0.37), and 30-day mortality was 4% and 6%, respectively (p = 0.48). Multivariate analysis identified preoperative platelet count (p = 0.01) and Freedom Solo (p < 0.0001) as independent risk factors for severe postoperative thrombocytopenia. After matching, severe thrombocytopenia occurred in 25% and 3% of patients with Freedom Solo and Perimount bioprostheses, respectively (p < 0.0001), thromboembolic or hemorrhagic events occurred in 0%, and 30-day mortality was 3% and 6%, respectively (p = 0.99). Conclusions. The risk of thrombocytopenia was high after Freedom Solo implantation. However, this complication was not related to any deleterious events in our study population. (Ann Thorac Surg 2010;89:1425-31) (C) 2010 by The Society of Thoracic Surgeons
引用
收藏
页码:1425 / 1431
页数:8
相关论文
共 50 条
  • [1] THROMBOCYTOPENIA AFTER AORTIC VALVE REPLACEMENT WITH THE FREEDOM SOLO STENTLESS BIOPROSTHESIS: A PROPENSITY-MATCHED STUDY
    Rusinaru, Dan
    Piccardo, Alessandro
    Petitprez, Benoit
    Marticho, Paul
    Vaida, Ioana
    Tribouilloy, Christophe
    Caus, Thierry
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [2] Unusual Complication after Aortic Valve Replacement with the Freedom™ Solo Stentless Bioprosthesis
    Celiento, Michele
    Scioti, Giovanni
    Pratali, Stefano
    Guarracino, Fabio
    Bortolotti, Uberto
    JOURNAL OF HEART VALVE DISEASE, 2011, 20 (05): : 604 - 606
  • [3] Thrombocytopenia after Aortic Valve Replacement with the Sorin Freedom Solo Prosthesis
    Reents, Wilko
    Babin-Ebell, Joerg
    Zacher, Michael
    Diegeler, Anno
    JOURNAL OF HEART VALVE DISEASE, 2011, 20 (03): : 313 - 318
  • [4] eComment. Platelet transfusion after aortic valve replacement by the Freedom Solo bioprosthesis
    Hajj-Chahine, Jamil
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 14 (04) : 438 - 439
  • [5] Aortic Valve Replacement With the Stentless Freedom SOLO Bioprosthesis: A Systematic Review
    Wollersheim, Laurens W.
    Li, Wilson W.
    Bouma, Berto J.
    Repossini, Alberto
    van der Meulen, Jan
    de Mol, Bas A.
    ANNALS OF THORACIC SURGERY, 2015, 100 (04): : 1496 - 1504
  • [6] Evaluation of platelet count after isolated biological aortic valve replacement with Freedom Solo bioprosthesis
    Miceli, Antonio
    Gilmanov, Daniyar
    Murzi, Michele
    Parri, Maria S.
    Cerillo, Alfredo G.
    Bevilacqua, Stefano
    Farneti, Pier A.
    Glauber, Mattia
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (01) : 69 - 73
  • [7] Early clinical and haemodynamic results after aortic valve replacement with the Freedom SOLO bioprosthesis (experience of Italian multicenter study)
    Repossini, Alberto
    Rambaldini, Manfredo
    Lucchetti, Vincenzo
    Da Col, Uberto
    Cesari, Francesco
    Mignosa, Carmelo
    Picano, Eugenio
    Glauber, Mattia
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (05) : 1104 - 1110
  • [8] Solo Smart stentless bioprosthesis for redo aortic valve replacement
    Hamasaki, Azumi
    Uchida, Tetsuro
    Sadahiro, Mitsuaki
    JOURNAL OF CARDIAC SURGERY, 2020, 35 (02) : 485 - 487
  • [9] Rare prosthesis failure after aortic valve replacement with a Freedom Solo
    Giordano, Vincenzo
    Hermens, Jeannine A. J. M.
    Wajon, Elly M. C. J.
    Grandjean, Jan G.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2011, 12 (02) : 273 - 275
  • [10] Use of Freedom SOLO bioprosthesis in aortic valve endocarditis involving the annulus
    Bortolussi, Giacomo
    Comisso, Marina
    Tarzia, Vincenzo
    Gerosa, Gino
    Bottio, Tomaso
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2016, 17 (02) : 165 - 166