A 433 MHz lucite cone waveguide applicator for superficial hyperthermia

被引:77
作者
Van Rhoon, GC [1 ]
Rietveld, PJM [1 ]
Van der Zee, J [1 ]
机构
[1] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, Dept Radiat Oncol, Sect Hyperthermia, NL-3008 AE Rotterdam, Netherlands
关键词
superficial hyperthermia; microwaves; SAR distribution; water filled waveguide applicator; MW applicator arrays;
D O I
10.3109/02656739809018211
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The effective held size (EFS, SAR > 50% of the maximum SAR at 1 cm depth) of a conventional 433 MHz water filled waveguide applicator (32 cm(2), aperture area 100 cm(2)) has been increased by: (1) replacement of the two diverging brass side walls which are parallel to the direction of the electric field by Lucite walls; and (2) Placement of a heterogeneous permittivity in the centre of the aperture. SAR distributions were measured at several depths in layered fat-muscle phantoms. With Lucite side walls the SAR distribution becomes wider in the H-plane of the aperture, resulting in a circular SAR distribution. In this situation the EFS is 67 cm(2). Additional insertion of a PVC cone with a top angle of 15 degrees at the centre of the aperture increases the EFS to 91 +/- 6 cm(2) for a waterbolus of 18 x 18 x 1 cm(3). The experiments also demonstrated that the resulting EFS is affected by the waterbolus size and shape. Calorimetric measurements showed that the efficiency of the improved applicator is comparable to the efficiency of the conventional water filled waveguide applicator, 50 and 56% respectively. The modifications reported provide a simple and inexpensive means to increase the EFS and can be easily implemented in water filled waveguide applicators.
引用
收藏
页码:13 / 27
页数:15
相关论文
共 26 条
[1]   DEPTH OF PENETRATION OF FIELDS FROM RECTANGULAR APERTURES INTO LOSSY MEDIA [J].
CHEEVER, E ;
LEONARD, JB ;
FOSTER, KR .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1987, 35 (09) :865-867
[2]   PRECLINICAL EVALUATION OF A MICROWAVE PLANAR ARRAY APPLICATOR FOR SUPERFICIAL HYPERTHERMIA [J].
DIEDERICH, CJ ;
STAUFFER, PR .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1993, 9 (02) :227-246
[3]  
Epis J. J., 1961, MICROWAVE J, V4, P84
[4]   CURRENT SHEET APPLICATOR ARRAYS FOR SUPERFICIAL HYPERTHERMIA OF CHESTWALL LESIONS [J].
GOPAL, MK ;
HAND, JW ;
LUMORI, MLD ;
ALKHAIRI, S ;
PAULSEN, KD ;
CETAS, TC .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1992, 8 (02) :227-240
[6]   QUALITY ASSURANCE GUIDELINES FOR ESHO PROTOCOLS [J].
HAND, JW ;
LAGENDIJK, JJW ;
ANDERSEN, JB ;
BOLOMEY, JC .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1989, 5 (04) :421-428
[7]  
HAND JW, 1987, PHYSICS TECHNOLOGY H, P189
[8]  
Handelsman J, 1990, METHODS EXTERNAL HYP, P1
[9]  
KANTOR G, 1981, J MICROWAVE POWER EE, V16, P135
[10]   BODY CONFORMABLE 915 MHZ MICROSTRIP ARRAY APPLICATORS FOR LARGE SURFACE-AREA HYPERTHERMIA [J].
LEE, ER ;
WILSEY, TR ;
TARCZYHORNOCH, P ;
KAPP, DS ;
FESSENDEN, P ;
LOHRBACH, A ;
PRIONAS, SD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (05) :470-483