Tibial base design and patient morphology affecting tibial coverage and rotational alignment after total knee arthroplasty

被引:43
作者
Clary, Chadd [1 ]
Aram, Luke [1 ]
Deffenbaugh, Daren [1 ]
Heldreth, Mark [1 ]
机构
[1] DePuy Synthes Joint Reconstruct, Warsaw, IN 46582 USA
关键词
Total knee arthroplasty; Tibial coverage; Tibial anthropometrics; Surgical technique; RISK-FACTORS; COMPONENT; REPLACEMENT; OVERHANG;
D O I
10.1007/s00167-014-3402-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To understand interactions between total knee arthroplasty tibial base design attributes, variations in tibial morphology, and the resulting tibial coverage and rotational alignment. Tibial anthropometric measurements, including aspect ratio (medial-lateral width/anterior-posterior length) and tibial asymmetry, were taken for 14,791 total knee arthroplasty patients and compared with the ability of four different commercial tibial base designs to cover the resected plateau. The anthropometric measurements were also compared with the resulting tibial base rotation, which occurred when rotating the base to maximize coverage. All four tibial base designs resulted in similar coverage ranging from 80.2 (4.7) % to 83.8 (4.6) %. Mean tibial base rotation when placed to maximize coverage ranged from 3.7 (4.4)A degrees (internal) to 3.8 (4.5)A degrees (external) relative to the medial third of the tibial tubercle. More asymmetric tibiae and tibiae with a lower aspect ratios resulted in increased internal tibial base rotation. The four tibial base designs assessed provided similar levels of tibial bone coverage across the patient population, despite different design features. Rotating the tibial base to maximize coverage did not significantly increase the tibial coverage, but induced variability in tibial base alignment. Certain tibial anthropometrics may predispose particular patients to internal tibial base mal-rotation.
引用
收藏
页码:3012 / 3018
页数:7
相关论文
共 50 条
  • [41] Tibial component coverage affects tibial bone resorption and patient-reported outcome measures for patients following total knee arthroplasty
    Liu, Changquan
    Zhao, Guanglei
    Chen, Kangming
    Lyu, Jinyang
    Chen, Jie
    Shi, Jingsheng
    Huang, Gangyong
    Chen, Feiyan
    Wei, Yibing
    Wang, Siqun
    Xia, Jun
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [42] Tibial component coverage affects tibial bone resorption and patient-reported outcome measures for patients following total knee arthroplasty
    Changquan Liu
    Guanglei Zhao
    Kangming Chen
    Jinyang Lyu
    Jie Chen
    Jingsheng Shi
    Gangyong Huang
    Feiyan Chen
    Yibing Wei
    Siqun Wang
    Jun Xia
    [J]. Journal of Orthopaedic Surgery and Research, 16
  • [43] Leg alignment and tibial slope after minimal invasive total knee arthroplasty: A prospective, randomized radiological study of intramedullary versus extramedullary tibial instrumentation
    de Kroon, Karin E.
    Houterman, Saskia
    Janssen, Rob P. A.
    [J]. KNEE, 2012, 19 (04) : 270 - 274
  • [44] Complications in Total Knee Arthroplasty After High Tibial Osteotomy
    Farfalli, Luis A.
    Farfalli, German L.
    Aponte-Tinao, Luis A.
    [J]. ORTHOPEDICS, 2012, 35 (04) : E464 - E468
  • [45] Influence of design features of tibial stems in total knee arthroplasty on tibial bone remodeling behaviors
    Jia, Zhengbin
    Gong, He
    Hu, Shimin
    Fang, Juan
    Fan, Ruoxun
    [J]. MEDICAL ENGINEERING & PHYSICS, 2017, 48 : 103 - 113
  • [46] Maximizing Tibial Coverage Is Detrimental to Proper Rotational Alignment
    Martin, Stacey
    Saurez, Alex
    Ismaily, Sabir
    Ashfaq, Kashif
    Noble, Philip
    Incavo, Stephen J.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (01) : 121 - 125
  • [47] Intraoperative Tibial Anteroposterior Axis Could Not Be Replicated After Tibial Osteotomy in Total Knee Arthroplasty
    Kawaguchi, Kohei
    Inui, Hiroshi
    Taketomi, Shuji
    Yamagami, Ryota
    Nakazato, Keiu
    Tanaka, Sakae
    [J]. JOURNAL OF ARTHROPLASTY, 2019, 34 (10) : 2371 - 2375
  • [48] Varus tibial alignment is associated with greater tibial baseplate migration at 10 years following total knee arthroplasty
    Teeter, Matthew G.
    Naudie, Douglas D.
    McCalden, Richard W.
    Yuan, Xunhua
    Holdsworth, David W.
    MacDonald, Steven J.
    Lanting, Brent A.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (06) : 1610 - 1617
  • [49] Total Knee Arthroplasty After High Tibial Osteotomy
    Cerciello, Simone
    Vasso, Michele
    Maffulli, Nicola
    Neyret, Philippe
    Corona, Katia
    Panni, Alfredo Schiavone
    [J]. ORTHOPEDICS, 2014, 37 (03) : 191 - 198
  • [50] Tibial component rotation in total knee arthroplasty
    Feczko, Peter Z.
    Pijls, Bart G.
    van Steijn, Michael J.
    van Rhijn, Lodewijk W.
    Arts, Jacobus J.
    Emans, Peter J.
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2016, 17