Tibial base design and patient morphology affecting tibial coverage and rotational alignment after total knee arthroplasty

被引:43
作者
Clary, Chadd [1 ]
Aram, Luke [1 ]
Deffenbaugh, Daren [1 ]
Heldreth, Mark [1 ]
机构
[1] DePuy Synthes Joint Reconstruct, Warsaw, IN 46582 USA
关键词
Total knee arthroplasty; Tibial coverage; Tibial anthropometrics; Surgical technique; RISK-FACTORS; COMPONENT; REPLACEMENT; OVERHANG;
D O I
10.1007/s00167-014-3402-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To understand interactions between total knee arthroplasty tibial base design attributes, variations in tibial morphology, and the resulting tibial coverage and rotational alignment. Tibial anthropometric measurements, including aspect ratio (medial-lateral width/anterior-posterior length) and tibial asymmetry, were taken for 14,791 total knee arthroplasty patients and compared with the ability of four different commercial tibial base designs to cover the resected plateau. The anthropometric measurements were also compared with the resulting tibial base rotation, which occurred when rotating the base to maximize coverage. All four tibial base designs resulted in similar coverage ranging from 80.2 (4.7) % to 83.8 (4.6) %. Mean tibial base rotation when placed to maximize coverage ranged from 3.7 (4.4)A degrees (internal) to 3.8 (4.5)A degrees (external) relative to the medial third of the tibial tubercle. More asymmetric tibiae and tibiae with a lower aspect ratios resulted in increased internal tibial base rotation. The four tibial base designs assessed provided similar levels of tibial bone coverage across the patient population, despite different design features. Rotating the tibial base to maximize coverage did not significantly increase the tibial coverage, but induced variability in tibial base alignment. Certain tibial anthropometrics may predispose particular patients to internal tibial base mal-rotation.
引用
收藏
页码:3012 / 3018
页数:7
相关论文
共 50 条
  • [31] Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border
    Jörg Lützner
    Frank Krummenauer
    Klaus-Peter Günther
    Stephan Kirschner
    BMC Musculoskeletal Disorders, 11
  • [32] Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border
    Luetzner, Joerg
    Krummenauer, Frank
    Guenther, Klaus-Peter
    Kirschner, Stephan
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [33] The medial border of the tibial tuberosity as an auxiliary tool for tibial component rotational alignment during total knee arthroplasty (TKA)
    Michael Drexler
    David Backstein
    Ueli Studler
    Dror Lakstein
    Barak Haviv
    Ran Schwarzkopf
    Tal Frenkel Rutenberg
    Yaniv Warschawski
    Ehud Rath
    Yona Kosashvili
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 1736 - 1742
  • [34] Soft-tissue landmarks for tibial baseplate rotational alignment in total knee arthroplasty: A cadaveric study
    Eseonu, Onyedikachi
    Mactier, Mhairi
    Ferguson, Eilidh
    Quondamatteo, Fabio
    Blyth, Mark
    Jones, Bryn
    CLINICAL ANATOMY, 2022, 35 (08) : 1107 - 1113
  • [35] Determining the rotational alignment of the tibial component referring to the tibial tubercle during total knee arthroplasty: the tibial tubercle–trochlear groove can be an aid
    He Zhang
    Chengming Cao
    Han Zhang
    Shoujiang Han
    Journal of Orthopaedic Surgery and Research, 17
  • [36] Rotational positioning of the tibial tray in total knee arthroplasty: A CT evaluation
    Berhouet, J.
    Beaufils, P.
    Boisrenoult, P.
    Frasca, D.
    Pujol, N.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (07) : 699 - 704
  • [37] Anatomic tibial component design can increase tibial coverage and rotational alignment accuracy: a comparison of six contemporary designs
    Dai, Yifei
    Scuderi, Giles R.
    Bischoff, Jeffrey E.
    Bertin, Kim
    Tarabichi, Samih
    Rajgopal, Ashok
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 2911 - 2923
  • [38] Rotational malalignment of the femoral and tibial components in total knee arthroplasty
    Nagamine, R
    Whiteside, LA
    Miura, H
    Urabe, K
    Matsuda, S
    Iwamoto, Y
    JOINT ARTHROPLASTY, 1999, : 373 - 383
  • [39] Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes
    Yamamura, Kazumasa
    Minoda, Yukihide
    Sugama, Ryo
    Ohta, Yoichi
    Nakamura, Suguru
    Ueyama, Hideki
    Nakamura, Hiroaki
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (05) : 1560 - 1567
  • [40] Tibial Rotational Alignment Was Significantly Improved by Use of a CT-Navigated Control Device in Total Knee Arthroplasty
    Kuriyama, Shinichi
    Hyakuna, Katsufumi
    Inoue, Satoshi
    Tamaki, Yasuyuki
    Ito, Hiromu
    Matsuda, Shuichi
    JOURNAL OF ARTHROPLASTY, 2014, 29 (12) : 2352 - 2356