Concurrent determination of anions and cations in consumer fireworks with a portable dual-capillary electrophoresis system

被引:39
|
作者
Saiz, Jorge [1 ,2 ]
Duc, Mai Thanh [3 ]
Koenka, Israel Joel [4 ]
Martin-Alberca, Carlos [1 ,2 ]
Hauser, Peter C. [4 ]
Garcia-Ruiz, Carmen [1 ,2 ]
机构
[1] Univ Alcala, Dept Analyt Chem Phys Chem & Chem Engn, Madrid 28871, Spain
[2] Univ Alcala, Univ Inst Res Police Sci IUICP, Madrid 28871, Spain
[3] Hanoi Univ Sci, Ctr Environm Technol & Sustainable Dev CETASD, Hanoi, Vietnam
[4] Univ Basel, Dept Chem, CH-4056 Basel, Switzerland
基金
瑞士国家科学基金会;
关键词
Dual-CE; Portable CE; Concurrent determination; Anions; Cations; Fireworks; INJECTION-ANALYSIS MANIFOLD; SIMULTANEOUS SEPARATION; ZONE-ELECTROPHORESIS; HYDRODYNAMIC INJECTION; INORGANIC ANIONS; WATER SAMPLES; IONS;
D O I
10.1016/j.chroma.2014.10.085
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new automated portable dual-channel capillary electrophoresis instrument was built and applied to the concurrent determination of cations and anions. The system uses a single buffer and hydrodynamic injection of the sample is performed autonomously. A novel engraved flow-cell interface is used at the injection ends of the capillaries allowing the autonomous operation of the system. The engraved flow-cell replaces traditionally used split injectors in purpose made capillary electrophoresis systems and makes the system design easier. A new software package with graphical user interface was employed to control the system, making its operation simple and increasing its versatility. The electrophoretic method was optimized to allow the baseline separation of 12 cations and anions commonly found in fireworks. The system was proven to be useful for the analysis of consumer fireworks, saving time and expenses compared to separate analyses for anions and cations. This is the first time that cationic and anionic compositions of fireworks are investigated together. The analysis of samples revealed several inaccuracies between the declared compositions for the fireworks and the obtained results, which could be attributed to cross-contamination during their manufacture or to a transfer between other components of the pyrotechnic item. The presence of certain unexpected peaks, however, had no apparent reason and might represent an irregularity in the manufacture of some devices. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:245 / 252
页数:8
相关论文
共 50 条
  • [21] SIMULTANEOUS DETERMINATION OF INORGANIC CATIONS AND ANIONS IN CAPILLARY ZONE ELECTROPHORESIS (CZE) WITH INDIRECT FLUORESCENCE DETECTION
    BACHMANN, K
    HAUMANN, I
    GROH, T
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 343 (12): : 901 - 902
  • [22] Simultaneous separation of inorganic anions and cations by capillary zone electrophoresis
    Padarauskas, A
    Olsauskaite, V
    Schwedt, G
    JOURNAL OF CHROMATOGRAPHY A, 1998, 800 (02) : 369 - 375
  • [23] Simultaneous separation of cations and anions in capillary electrophoresis - recent applications
    Koenka, Israel Joel
    Mai, Thanh Duc
    Hauser, Peter C.
    Saiz, Jorge
    ANALYTICAL METHODS, 2016, 8 (07) : 1452 - 1456
  • [24] Ion association with alkylammonium cations for separation of anions by capillary electrophoresis
    Steiner, SA
    Watson, DM
    Fritz, JS
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1085 (01) : 170 - 175
  • [25] STUDIES ON THE DETERMINATION OF INORGANIC ANIONS BY CAPILLARY ELECTROPHORESIS
    BENZ, NJ
    FRITZ, JS
    JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) : 437 - 443
  • [26] Concurrent determination and separation of inorganic cations and anions in microchip electrophoresis with precisely controlled high-voltage
    Huang, Zhe
    Yang, Mingpeng
    You, Hui
    Xie, Yang
    ELECTROPHORESIS, 2018, 39 (14) : 1802 - 1807
  • [27] A bi-end injection capillary electrophoresis method for simultaneous determination of 37 cations and anions in beers
    Chao Guo
    Zhenpeng Guo
    Yi Chen
    Analytical and Bioanalytical Chemistry, 2019, 411 : 4113 - 4121
  • [28] On-line dialysis coupled to a capillary electrophoresis system for determination of small anions
    Kuban, P
    Karlberg, B
    ANALYTICAL CHEMISTRY, 1997, 69 (06) : 1169 - 1173
  • [29] A bi-end injection capillary electrophoresis method for simultaneous determination of 37 cations and anions in beers
    Guo, Chao
    Guo, Zhenpeng
    Chen, Yi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (18) : 4113 - 4121
  • [30] Capillary electrophoresis of the major anions and cations in leaf extracts of woody species
    Warren, CR
    Adams, MA
    PHYTOCHEMICAL ANALYSIS, 2004, 15 (06) : 407 - 413