Long-term outcome of percutaneous catheter intervention for de novo coronary bifurcation lesions with drug-eluting stents or bare-metal stents

被引:26
作者
Ferenc, Miroslaw [1 ]
Gick, Michael [1 ]
Kienzle, Rolf-Peter [1 ]
Bestehorn, Hans-Peter [1 ]
Werner, Klaus-Dieter [1 ]
Comberg, Thomas [1 ]
Zhao, Min [1 ]
Buettner, Heinz Joachim [1 ]
Neumann, Franz-Josef [1 ]
机构
[1] Herz Zentrum Bad Krozingen, D-79189 Bad Krozingen, Germany
关键词
THROMBOSIS; IMMEDIATE; IMPLANTATION;
D O I
10.1016/j.ahj.2009.11.032
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The purpose of this study was to assess the long-term risks and benefits of drug-eluting stents (DESs) compared with bare-metal stents (BMSs) for treatment of coronary bifurcation lesions. Methods Our registry comprised 1,038 patients treated for coronary bifurcation lesion according to the provisional T-stenting strategy who were followed up for 3 years. Results Target lesion revascularization rates were 24.3% for BMSs (n = 337), 15.6% for sirolimus-eluting stents (SESs, n = 422), and 17.3% for paclitaxel-eluting stents (PESs, n = 279) (P = .003 BMSs vs DESs, P = .54 SESs vs PESs). The respective incidences were 11.4%, 9.5%, and 14.8% (P = .65, P = .13) for death and myocardial infarction and 9.9%, 6.5%, and 10.6% (P = .72, P = .19) for death. Propensity score adjusted hazard ratios (95% CI) for DESs versus BMSs were 0.49 (0.35-0.68, P < .001) for target lesion revascularization, 0.94 (0.64-1.40, P = .078) for death and myocardial infarction, and 0.85 (0.55-1.32, P = .47) for death. We did not find any significant differences between SESs and PESs, except for an increased risk of death after PESs compared with SESs (but not BMSs) in the subgroup receiving a side-branch stent (adjusted hazard ratio 2.45, 95% CI 1.05-5.73, P = .035). Conclusions Compared with BMSs, both PESs and SESs substantially reduced the long-term need for repeated revascularization but did not increase the risk of death and myocardial infarction. (Am Heart J 2010; 159:454-61.)
引用
收藏
页码:454 / 461
页数:8
相关论文
共 20 条
[1]   Immediate and long-term outcome of intracoronary stent implantation for true bifurcation lesions [J].
Al Suwaidi, J ;
Berger, PB ;
Rihal, CS ;
Garratt, KN ;
Bell, MR ;
Ting, HH ;
Bresnahan, JF ;
Grill, DE ;
Holmes, DR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (04) :929-936
[2]   Immediate and one-year outcome in patients with coronary bifurcation lesions in the modern era (NHLBI Dynamic Registry) [J].
Al Suwaidi, J ;
Yeh, WL ;
Cohen, HA ;
Detre, KM ;
Williams, DO ;
Holmes, DR .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (10) :1139-1144
[3]   Myocardial infarction redefined -: A consensus Document of the Joint European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction [J].
Alpert, JS ;
Antman, E ;
Apple, F ;
Armstrong, PW ;
Bassand, JP ;
de Luna, AB ;
Beller, G ;
Breithardt, G ;
Chaitman, BR ;
Clemmensen, P ;
Falk, E ;
Fishbein, MC ;
Galvani, M ;
Garson, A ;
Grines, C ;
Hamm, C ;
Jaffe, A ;
Katus, H ;
Kjekshus, J ;
Klein, W ;
Klootwijk, P ;
Lenfant, C ;
Levy, D ;
Levy, RI ;
Luepker, R ;
Marcus, F ;
Näslund, U ;
Ohman, M ;
Pahlm, O ;
Poole-Wilson, P ;
Popp, R ;
Alto, P ;
Pyörälä, K ;
Ravkilde, J ;
Rehnquist, N ;
Roberts, W ;
Roberts, R ;
Roelandt, J ;
Rydén, L ;
Sans, S ;
Simoons, ML ;
Thygesen, K ;
Tunstall-Pedoe, H ;
Underwood, R ;
Uretsky, BF ;
Van de Werf, F ;
Voipio-Pulkki, LM ;
Wagner, G ;
Wallentin, L ;
Wijns, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) :959-969
[4]   Randomized study to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions [J].
Colombo, A ;
Moses, JW ;
Morice, MC ;
Ludwig, J ;
Holmes, DR ;
Spanos, V ;
Louvard, Y ;
Desmedt, B ;
Di Mario, C ;
Leon, MB .
CIRCULATION, 2004, 109 (10) :1244-1249
[5]   Randomized Study of the Crush Technique Versus Provisional Side-Branch Stenting in True Coronary Bifurcations The CACTUS (Coronary Bifurcations: Application of the Crushing Technique Using Sirolimus-Eluting Stents) Study [J].
Colombo, Antonio ;
Bramucci, Ezio ;
Sacca, Salvatore ;
Violini, Roberto ;
Lettieri, Corrado ;
Zanini, Roberto ;
Sheiban, Imad ;
Paloscia, Leonardo ;
Grube, Eberhard ;
Schofer, Joachim ;
Bolognese, Leonardo ;
Orlandi, Mario ;
Niccoli, Giampaolo ;
Latib, Azeem ;
Airoldi, Flavio .
CIRCULATION, 2009, 119 (01) :71-U118
[6]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[7]   Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice:: data from a large two-institutional cohort study [J].
Daemen, Joost ;
Wenaweser, Peter ;
Tsuchida, Keiichi ;
Abrecht, Linda ;
Sophia, Vaina ;
Morger, Cyrill ;
Kukreja, Neville ;
Jueni, Peter ;
Sianos, Georgios ;
Hellige, Gerrit ;
van Domburg, Ron T. ;
Hess, Otto M. ;
Boersma, Eric ;
Meier, Bernhard ;
Windecker, Stephan ;
Serruys, Patrick W. .
LANCET, 2007, 369 (9562) :667-678
[8]   Randomized trial on routine vs. provisional T-stenting in the treatment of de novo coronary bifurcation lesions [J].
Ferenc, Miroslaw ;
Gick, Michael ;
Kienzle, Rolf-Peter ;
Bestehorn, Hans-Peter ;
Werner, Klaus-Dieter ;
Comberg, Thomas ;
Kuebler, Piotr ;
Buettner, Heinz Joachim ;
Neumann, Franz-Josef .
EUROPEAN HEART JOURNAL, 2008, 29 (23) :2859-2867
[9]   Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents [J].
Iakovou, I ;
Schmidt, T ;
Bonizzoni, E ;
Ge, L ;
Sangiorgi, GM ;
Stankovic, G ;
Airoldi, F ;
Chieffo, A ;
Montorfano, M ;
Carlino, M ;
Michev, I ;
Corvaja, N ;
Briguori, C ;
Gerckens, U ;
Grube, E ;
Colombo, A .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (17) :2126-2130
[10]  
Lefèvre T, 2000, CATHETER CARDIO INTE, V49, P274, DOI 10.1002/(SICI)1522-726X(200003)49:3<274::AID-CCD11>3.0.CO