Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients

被引:595
作者
Barbier, C
Loubières, Y
Schmit, C
Hayon, J
Ricôme, JL
Jardin, FO
Vieillard-Baron, A
机构
[1] Univ Hosp Ambroise Pare, Assistance Publ Hop Paris, Med Intens Care Unit, F-92104 Boulogne, France
[2] Hosp St Germain en Laye, Med & Surg Intens Care Unit, F-78100 St Germain En Laye, France
关键词
D O I
10.1007/s00134-004-2259-8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate the extent to which respiratory changes in inferior vena cava (IVC) diameter can be used to predict fluid responsiveness. Design: Prospective clinical study. Setting: Hospital intensive care unit. Patients: Twenty-three patients with acute circulatory failure related to sepsis and mechanically ventilated because of an acute lung injury. Measurements: Inferior vena cava diameter (D) at end-expiration (Dmin) and at end-inspiration (Dmax) was measured by echocardiography using a subcostal approach. The distensibility index of the IVC (dIVC) was calculated as the ratio of Dmax-Dmin/Dmin, and expressed as a percentage. The Doppler technique was applied in the pulmonary artery trunk to determine cardiac index (CI). Measurements were performed at baseline and after a 7 ml/kg volume expansion using a plasma expander. Patients were separated into responders (increase in CI greater than or equal to15%) and non-responders (increase in CIless than or equal to15%). Results: Using a threshold dIVC of 18%, responders and non-responders were discriminated with 90% sensitivity and 90% specificity. A strong relation (r=0.9) was observed between dIVC at baseline and the CI increase following blood volume expansion. Baseline central venous pressure did not accurately predict fluid responsiveness. Conclusion: Our study suggests that respiratory change in IVC diameter is an accurate predictor of fluid responsiveness in septic patients.
引用
收藏
页码:1740 / 1746
页数:7
相关论文
共 26 条
  • [1] *AM COLL CHEST PHY, 1992, CRIT CARE MED, V27, P864
  • [2] Antunes T, 2002, INTENS CARE MED, V28, pS34
  • [3] CALVIN JE, 1981, SURGERY, V90, P61
  • [4] COMOLET R, 1984, BIOMECANIQUE CIRCULA, P36
  • [5] Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock
    Feissel, M
    Michard, F
    Mangin, I
    Ruyer, O
    Faller, JP
    Teboul, JL
    [J]. CHEST, 2001, 119 (03) : 867 - 873
  • [6] Estimation of intra-abdominal pressure by bladder pressure measurement: Validity and methodology
    Fusco, MA
    Martin, RS
    Chang, MC
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 50 (02): : 297 - 302
  • [7] Guyton A, 1973, CIRCULATORY PHYSL CA
  • [8] INFLUENCE OF LUNG AND CHEST WALL COMPLIANCES ON TRANSMISSION OF AIRWAY PRESSURE TO THE PLEURAL SPACE IN CRITICALLY ILL PATIENTS
    JARDIN, F
    GENEVRAY, B
    BRUNNEY, D
    BOURDARIAS, JP
    [J]. CHEST, 1985, 88 (05) : 653 - 658
  • [9] INSPIRATORY IMPAIRMENT IN RIGHT VENTRICULAR PERFORMANCE DURING ACUTE ASTHMA
    JARDIN, F
    DUBOURG, O
    MARGAIRAZ, A
    BOURDARIAS, JP
    [J]. CHEST, 1987, 92 (05) : 789 - 795
  • [10] THE COLLAPSED INFERIOR VENA-CAVA - CT EVIDENCE OF HYPOVOLEMIA
    JEFFREY, RB
    FEDERLE, MP
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (02) : 431 - 432