Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients

被引:609
作者
Barbier, C
Loubières, Y
Schmit, C
Hayon, J
Ricôme, JL
Jardin, FO
Vieillard-Baron, A
机构
[1] Univ Hosp Ambroise Pare, Assistance Publ Hop Paris, Med Intens Care Unit, F-92104 Boulogne, France
[2] Hosp St Germain en Laye, Med & Surg Intens Care Unit, F-78100 St Germain En Laye, France
关键词
D O I
10.1007/s00134-004-2259-8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate the extent to which respiratory changes in inferior vena cava (IVC) diameter can be used to predict fluid responsiveness. Design: Prospective clinical study. Setting: Hospital intensive care unit. Patients: Twenty-three patients with acute circulatory failure related to sepsis and mechanically ventilated because of an acute lung injury. Measurements: Inferior vena cava diameter (D) at end-expiration (Dmin) and at end-inspiration (Dmax) was measured by echocardiography using a subcostal approach. The distensibility index of the IVC (dIVC) was calculated as the ratio of Dmax-Dmin/Dmin, and expressed as a percentage. The Doppler technique was applied in the pulmonary artery trunk to determine cardiac index (CI). Measurements were performed at baseline and after a 7 ml/kg volume expansion using a plasma expander. Patients were separated into responders (increase in CI greater than or equal to15%) and non-responders (increase in CIless than or equal to15%). Results: Using a threshold dIVC of 18%, responders and non-responders were discriminated with 90% sensitivity and 90% specificity. A strong relation (r=0.9) was observed between dIVC at baseline and the CI increase following blood volume expansion. Baseline central venous pressure did not accurately predict fluid responsiveness. Conclusion: Our study suggests that respiratory change in IVC diameter is an accurate predictor of fluid responsiveness in septic patients.
引用
收藏
页码:1740 / 1746
页数:7
相关论文
共 26 条
[1]  
*AM COLL CHEST PHY, 1992, CRIT CARE MED, V27, P864
[2]  
Antunes T, 2002, INTENS CARE MED, V28, pS34
[3]  
CALVIN JE, 1981, SURGERY, V90, P61
[4]  
COMOLET R, 1984, BIOMECANIQUE CIRCULA, P36
[5]   Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock [J].
Feissel, M ;
Michard, F ;
Mangin, I ;
Ruyer, O ;
Faller, JP ;
Teboul, JL .
CHEST, 2001, 119 (03) :867-873
[6]   Estimation of intra-abdominal pressure by bladder pressure measurement: Validity and methodology [J].
Fusco, MA ;
Martin, RS ;
Chang, MC .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 50 (02) :297-302
[7]  
Guyton A, 1973, CIRCULATORY PHYSL CA
[8]   INFLUENCE OF LUNG AND CHEST WALL COMPLIANCES ON TRANSMISSION OF AIRWAY PRESSURE TO THE PLEURAL SPACE IN CRITICALLY ILL PATIENTS [J].
JARDIN, F ;
GENEVRAY, B ;
BRUNNEY, D ;
BOURDARIAS, JP .
CHEST, 1985, 88 (05) :653-658
[9]   INSPIRATORY IMPAIRMENT IN RIGHT VENTRICULAR PERFORMANCE DURING ACUTE ASTHMA [J].
JARDIN, F ;
DUBOURG, O ;
MARGAIRAZ, A ;
BOURDARIAS, JP .
CHEST, 1987, 92 (05) :789-795
[10]   THE COLLAPSED INFERIOR VENA-CAVA - CT EVIDENCE OF HYPOVOLEMIA [J].
JEFFREY, RB ;
FEDERLE, MP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (02) :431-432