Quantitative Determination of Cyfluthrin in N-Hexane by Terahertz Time-Domain Spectroscopy With Chemometrics Methods

被引:52
作者
Hua, Yuefang [1 ]
Zhang, Hongjian [1 ]
Zhou, Hongliang [1 ]
机构
[1] Zhejiang Univ, State Key Lab Ind Control Technol, Dept Control Sci & Engn, Hangzhou 310027, Peoples R China
关键词
Cyfluthrin; least-squares support vector machine (LS-SVM); partial least squares (PLS); pesticide; quantitative; terahertz time-domain spectroscopy (THz-TDS); FOURIER-TRANSFORM SPECTROSCOPY; CHEMICAL-IONIZATION MODE; SUPPORT VECTOR MACHINES; PYRETHROID INSECTICIDES; RAMAN-SPECTROMETRY; CHROMATOGRAPHY; AGROCHEMICALS; TECHNOLOGY; WATER; WAVE;
D O I
10.1109/TIM.2010.2041020
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the preliminary research in detecting pesticide residues with the newly developed terahertz technique. Experiments were carried out on cyfluthrin n-hexane solutions in the concentration range of 1-20 mu g/ml with terahertz time-domain spectroscopy (THz-TDS). We employed four calibration methods for the regression between the absorbance and the concentration of the solutions, i.e., linear regression methods of simple linear regression (SLR), partial least squares (PLS), and nonlinear regression methods of simple least-squares support vector machine (LS-SVM), and the combination of PLS and LS-SVM (PLS-LS-SVM), which utilizes the features extracted by PLS from the original absorbance spectra as the input of LS-SVM. To analyze the antinoise abilities of these models, we collected two data sets of the same series of samples on two different days, i.e., one with higher signal-to-noise ratio (SNR) and the other with lower SNR. Separate models were built on them. We find that the PLS and PLS-LS-SVM models present much better prediction and antinoise abilities than the SLR and simple LS-SVM models, whereas PLS-LS-SVM outperforms PLS, showing much less dependence on the selection of the number of the features extracted. To further analyze the influence of the selection of the frequency range, we built different PLS-LS-SVM models by varying the frequency ranges between 0.5 and 1.5 THz, and find that the model performance dramatically varies with the selection of different frequency ranges, which may be due to the unevenly distributed SNR and the spectroscopic interaction variations in different frequency ranges. The selection of the whole frequency range of 0.5-1.5 THz results in relatively low prediction error with either the higher or the lower SNR spectra and will thus be selected for further modeling. The overall results indicate that the THz-TDS plus PLS-LS-SVM method proves to be an effective tool for the quantitative analysis of cyfluthrin n-hexane solutions and may provide a new technique for further pesticide residue detection.
引用
收藏
页码:1414 / 1423
页数:10