Proposed Adjustments to PI-RADS Version 2 Decision Rules: Impact on Prostate Cancer Detection

被引:136
作者
Rosenkrantz, Andrew B. [1 ]
Babb, James S. [1 ]
Taneja, Samir S. [2 ]
Ream, Justin M. [1 ]
机构
[1] NYU, Langone Med Ctr, NYU Sch Med, Dept Radiol,Ctr Biomed Imaging, 660 First Ave,3rd Floor, New York, NY 10016 USA
[2] NYU, Langone Med Ctr, NYU Sch Med, Dept Urol,Div Urol Oncol, 660 First Ave,3rd Floor, New York, NY 10016 USA
关键词
APPARENT DIFFUSION-COEFFICIENT; DATA SYSTEM; MRI ASSESSMENT; IMAGE QUALITY; T; BIOPSY; FUSION; MEN; LOCALIZATION;
D O I
10.1148/radiol.2016161124
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To test the impact of existing Prostate Imaging Reporting and Data System (PI-RADS) version 2 (V2) decision rules, as well as of proposed adjustments to these decision rules, on detection of Gleason score (GS) 7 or greater ( GS >= 7) prostate cancer. Materials and Methods: Two radiologists independently provided PI-RADS V2 scores for the dominant lesion on 343 prostate magnetic resonance (MR) examinations. Diagnostic performance for GS >= 7 tumor was assessed by using MR imaging-ultrasonography fusion-targeted biopsy as the reference. The impact of existing PI-RADS V2 decision rules, as well as a series of exploratory proposed adjustments, on the frequency of GS >= 7 tumor detection, was evaluated. Results: A total of 210 lesions were benign, 43 were GS 6, and 90 were GS >= 7. Lesions were GS >= 7 in 0%-4.1% of PI-RADS categories 1 and 2, 11.4%-27.1% of PI-RADS category 3, 44.4%-49.3% of PI-RADS category 4, and 72.1%-73.7% of PI-RADS category 5 lesions. PI-RADS category 4 or greater had sensitivity of 78.9%-87.8% and specificity of 75.5%-79.1 for detecting GS >= 7 tumor. The frequency of GS >= 7 tumor for existing PI-RADS V2 decision rules was 30.0%-33.3% in peripheral zone (PZ) lesions upgraded from category 3 to 4 based on dynamic contrast enhancement (DCE) score of positive; 50.0%-66.7% in transition zone (TZ) lesions upgraded from category 3 to 4 based on diffusion-weighted imaging (DWI) score of 5; and 71.7%-72.7% of lesions in both zones upgraded from category 4 to 5 based on size of 15 mm or greater. The frequency of GS >= 7 tumor for proposed adjustments to the decision rules was 30.0%-60.0% for TZ lesions upgraded from category 3 to 4 based on DWI score of 4; 33.3%-57.1% for TZ lesions upgraded from category 3 to 4 based on DCE score of positive when incorporating new criteria ( unencapsulated sheetlike enhancement) for DCE score of positive in TZ; and 56.4%-61.9% for lesions in both zones upgraded from category 4 to 5 based on size of 10-14 mm. Other proposed adjustments yielded GS >= 7 tumor in less than 15% of cases for one or more readers. Conclusion: Existing PI-RADS V2 decision rules exhibited reasonable performance in detecting GS >= 7 tumor. Several proposed adjustments to the criteria ( in TZ, upgrading category 3 to 4 based on DWI score of 4 or modified DCE score of positive; in PZ or TZ, upgrading category 4 to 5 based on size of 10-14 mm) may also have value for this purpose. (C) RSNA, 2016
引用
收藏
页码:119 / 129
页数:11
相关论文
共 33 条
[1]  
[Anonymous], J MAGN RESON IMAGING
[2]  
[Anonymous], LIV IM REP DAT SYST
[3]  
Baldisserotto M, 2016, J MAGN RESON IMAGING
[4]   ESUR prostate MR guidelines 2012 [J].
Barentsz, Jelle O. ;
Richenberg, Jonathan ;
Clements, Richard ;
Choyke, Peter ;
Verma, Sadhna ;
Villeirs, Geert ;
Rouviere, Olivier ;
Logager, Vibeke ;
Futterer, Jurgen J. .
EUROPEAN RADIOLOGY, 2012, 22 (04) :746-757
[5]   Differentiating Transition Zone Cancers From Benign Prostatic Hyperplasia by Quantitative Multiparametric Magnetic Resonance Imaging [J].
Elbuluk, Osama ;
Muradyan, Naira ;
Shih, Joanna ;
Bernardo, Marcelino ;
Sankineni, Sandeep ;
Merino, Maria J. ;
Wood, Bradford J. ;
Pinto, Peter A. ;
Choyke, Peter L. ;
Turkbey, Baris .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (02) :218-224
[6]   Value of 3-T Multiparametric Magnetic Resonance Imaging and Magnetic Resonance-Guided Biopsy for Early Risk Restratification in Active Surveillance of Low-Risk Prostate Cancer A Prospective Multicenter Cohort Study [J].
Hoeks, Caroline M. A. ;
Somford, Diederik M. ;
van Oort, Inge M. ;
Vergunst, Henk ;
Oddens, Jorg R. ;
Smits, Geert A. ;
Roobol, Monique J. ;
Bul, Meelan ;
Hambrock, Thomas ;
Witjes, J. Alfred ;
Fuetterer, Jurgen J. ;
Hulsbergen-van de Kaa, Christina A. ;
Barentsz, Jelle O. .
INVESTIGATIVE RADIOLOGY, 2014, 49 (03) :165-172
[7]   Transition Zone Prostate Cancer: Detection and Localization with 3-T Multiparametric MR Imaging [J].
Hoeks, Caroline M. A. ;
Hambrock, Thomas ;
Yakar, Derya ;
de Kaa, Christina A. Hulsbergen-van ;
Feuth, Ton ;
Witjes, J. Alfred ;
Futterer, Jurgen J. ;
Barentsz, Jelle O. .
RADIOLOGY, 2013, 266 (01) :207-217
[8]   Prostate Cancer: Multiparametric MR Imaging for Detection, Localization, and Staging [J].
Hoeks, Caroline M. A. ;
Barentsz, Jelle O. ;
Hambrock, Thomas ;
Yakar, Derya ;
Somford, Diederik M. ;
Heijmink, Stijn W. T. P. J. ;
Scheenen, Tom W. J. ;
Vos, Pieter C. ;
Huisman, Henkjan ;
van Oort, Inge M. ;
Witjes, J. Alfred ;
Heerschap, Arend ;
Fuetterer, Jurgen J. .
RADIOLOGY, 2011, 261 (01) :46-66
[9]   Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis [J].
Martin, Peter R. ;
Cool, Derek W. ;
Romagnoli, Cesare ;
Fenster, Aaron ;
Ward, Aaron D. .
MEDICAL PHYSICS, 2014, 41 (07)
[10]  
Mendhiratta N, 2015, UROLOGY, V86, P1192, DOI 10.1016/j.urology.2015.07.038