Remote Magnetic Navigation: A Focus on Catheter Ablation of Ventricular Arrhythmias

被引:14
|
作者
Aagaard, Philip [1 ]
Natale, Andrea [2 ,4 ,5 ,6 ,7 ,8 ,9 ]
Briceno, David [1 ]
Nakagawa, Hiroshi [10 ]
Mohanty, Sanghamitra [2 ]
Gianni, Carola [2 ]
Burkhardt, J. David [2 ]
Di Biase, Luigi [1 ,2 ,3 ,4 ]
机构
[1] Montefiore Med Ctr, Albert Einstein Coll Med, Montefiore Einstein Ctr Heart & Vasc Care, 111 East 210th St, Bronx, NY 10467 USA
[2] St Davids Med Ctr, Texas Cardiac Arrhythmia Inst, Austin, TX USA
[3] Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA
[4] Univ Foggia, Dept Cardiol, Foggia, Italy
[5] Stanford Univ, Div Cardiol, Stanford, CA 94305 USA
[6] Case Western Reserve Univ, Cleveland, OH 44106 USA
[7] Calif Pacific Med Ctr, EP Serv, San Francisco, CA USA
[8] Scripps Clin, Intervent Electrophysiol, San Diego, CA USA
[9] Univ Texas Austin, Dell Med Sch, Austin, TX 78712 USA
[10] Univ Oklahoma, Hlth Sci Ctr, Heart Rhythm Inst, Oklahoma City, OK USA
关键词
catheter ablation; remote magnetic navigation; Stereotaxis; ventricular tachycardia; ATRIAL-FIBRILLATION ABLATION; INITIAL CLINICAL-EXPERIENCE; OUTFLOW TRACT TACHYCARDIA; IRRIGATED-TIP CATHETER; RADIOFREQUENCY ABLATION; EPICARDIAL ABLATION; ELECTRICAL STORM; CONTACT FORCE; SYSTEM; EFFICACY;
D O I
10.1111/jce.12938
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A Focus on Catheter Ablation of Ventricular Arrhythmias VT ablation is based on percutaneous catheter insertion under fluoroscopic guidance to selectively destroy (i.e., ablate) myocardial tissue regions responsible for the initiation or propagation of ventricular arrhythmias. Although the last decade has witnessed a rapid evolution of ablation equipment and techniques, the control over catheter movement during manual ablation has remained largely unchanged. Moreover, the procedures are long, and require ergonomically unfavorable positions, which can lead to operator fatigue. In an attempt to overcome these constraints, several technical advancements, including remote magnetic navigation (RMN), have been developed. RMN utilizes a magnetic field to remotely manipulate specially designed soft-tip ablation catheters anywhere in the x, y, or z plane inside the patient's chest. RMN also facilitates titration of the contact force between the catheter and the myocardial tissue, which may reduce the risk of complications while ensuring adequate lesion formation. There are several non-randomized studies showing that RMN has similar efficacy to manual ablation, while complication rates and total radiation exposure appears to be lower. Although these data are promising, larger randomized studies are needed to prove that RMN is superior to manual ablation of VT.
引用
收藏
页码:S38 / S44
页数:7
相关论文
共 50 条
  • [11] Catheter-based ablation for ventricular arrhythmias
    John R.M.
    Stevenson W.G.
    Current Cardiology Reports, 2011, 13 (5) : 399 - 406
  • [12] Remote magnetic navigation vs. manual navigation for ablation of ventricular tachycardia: a meta-analysis
    Wu, Y.
    Li, K. -L.
    Zheng, J.
    Zhang, C. -Y.
    Liu, X. -Y.
    Cui, Z. -M.
    Yu, Z. -M.
    Wang, R. -X.
    Wang, W.
    NETHERLANDS HEART JOURNAL, 2015, 23 (10) : 485 - 490
  • [13] Safety and efficacy of the remote magnetic navigation for ablation of ventricular tachycardias-a systematic review
    Akca, Ferdi
    Onsesveren, Ibrahim
    Jordaens, Luc
    Szili-Torok, Tamas
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 34 (01) : 65 - 71
  • [14] A meta-analysis of manual versus remote magnetic navigation for ventricular tachycardia ablation
    Turagam, Mohit K.
    Atkins, Donita
    Tung, Roderick
    Mansour, Moussa
    Ruskin, Jeremy
    Cheng, Jie
    Di Biase, Luigi
    Natale, Andrea
    Lakkireddy, Dhanunjaya
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2017, 49 (03) : 227 - 235
  • [15] Robotic magnetic navigation for ablation of human arrhythmias: Initial experience
    Latcu, Decebal G.
    Ricard, Philippe
    Zarqane, Naima
    Yaici, Khelil
    Rinaldi, Jean-Paul
    Maluski, Alexandre
    Saoudi, Nadir
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2009, 102 (05) : 419 - 425
  • [16] Long-Term Efficacy of Single Procedure Remote Magnetic Catheter Navigation for Ablation of Ischemic Ventricular Tachycardia: A Retrospective Study
    Dinov, Borislav
    Schoenbauer, Robert
    Wojdyla-Hordynska, Agnieska
    Braunschweig, Frieder
    Richter, Sergio
    Altmann, David
    Sommer, Philipp
    Gaspar, Thomas
    Bollmann, Andreas
    Wetzel, Ulrike
    Rolf, Sascha
    Piorkowski, Christopher
    Hindricks, Gerhard
    Arya, Arash
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (05) : 499 - 505
  • [17] Prediction and prognosis of ventricular tachycardia recurrence after catheter ablation with remote magnetic navigation for electrical storm in patients with ischemic cardiomyopathy
    Jin, Qi
    Jacobsen, Peter Karl
    Pehrson, Steen
    Chen, Xu
    CLINICAL CARDIOLOGY, 2017, 40 (11) : 1083 - 1089
  • [18] Remote magnetic navigation and arrhythmia ablation
    Da Costa, Antoine
    Lafond, Patrick
    Romeyer-Bouchard, Cecile
    Gate-Martinet, Alexie
    Bisch, Laurence
    Nadrouss, Abdallah
    Isaaz, Karl
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2012, 105 (8-9) : 446 - 453
  • [19] Robotics for catheter ablation of cardiac arrhythmias: Current technologies and practical approaches
    Bassil, Guillaume
    Markowitz, Steven M.
    Liu, Christopher F.
    Thomas, George
    Ip, James E.
    Lerman, Bruce B.
    Cheung, Jim W.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (03) : 739 - 752
  • [20] The First Evaluation of Remote Magnetic Navigation-Guided Pediatric Ventricular Arrhythmia Ablation
    Anna M. E. Noten
    Nawin L. Ramdat Misier
    Janneke A. E. Kammeraad
    Sip Wijchers
    Ingrid M. Van Beynum
    Michiel Dalinghaus
    Thomas B. Krasemann
    Sing-Chien Yap
    Natasja M. S. de Groot
    Tamas Szili-Torok
    Pediatric Cardiology, 2022, 43 : 1695 - 1703