A tandem-flow assembly for the chemiluminometric determination of hydroquinone

被引:40
作者
Corominas, BGT
Catalá-Icardo, M
Zamora, LL
Mateo, JVG
Calatayud, JM [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, Valencia, Spain
[2] Univ Cardenal Herrera, Dept Chem Biochem & Mol Biol, CEU, Valencia, Spain
关键词
hydroquinone; chemiluminescence; tandem-flow; pharmaceuticals; environmental samples;
D O I
10.1016/j.talanta.2004.03.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A direct chemiluminescent procedure for determination of hydroquinone based on the emergent flow methodology known as multicommutation or tandem-flow is presented for first time. The manifold was based on a set of three channels and three solenoid valves; and, the determination was performed at 60degreesC and at flow-rate of 7.5 ml min(-1). The complete cycle lasted 35 s, which resulted in a sample flow trough of 103 h(-1). The chemical process was the hydroquinone oxidation with the system sulphuric acid-potassium permanganate; and the light emission was clearly enhanced by the presence of quinine sulphate and benzalkonium chloride reaching a detection limit of 30 Rg l(-1). The dynamic interval was over the range 0.1-15.0 mgl(-1) and a large list of interferents were assayed; the chemical robustness was also tested. The method was applied to different type of samples: namely, pharmaceutical formulations, a photographic solution and irrigation and residual superficial waters. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:618 / 625
页数:8
相关论文
共 27 条