Altered Biodistribution and Incidental Findings on Myocardial Perfusion Imaging

被引:13
作者
Chamarthy, Murthy [1 ]
Travin, Mark I. [1 ]
机构
[1] Albert Einstein Coll Med, Dept Nucl Med, Montefiore Med Ctr, Bronx, NY 10467 USA
关键词
EMISSION COMPUTED-TOMOGRAPHY; RIGHT-VENTRICULAR DYSFUNCTION; CORONARY-ARTERY-DISEASE; PRIMARY BREAST-CANCER; CELL LUNG-CANCER; TC-99M SESTAMIBI; TL-201; SCINTIGRAPHY; TECHNETIUM-99M-MIBI UPTAKE; NONCARDIAC FINDINGS; MALIGNANT-LYMPHOMA;
D O I
10.1053/j.semnuclmed.2010.03.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Myocardial perfusion studies routinely are performed to evaluate for the presence and extent of coronary artery disease. The findings have prognostic and therapeutic implications. Routine display of the raw projection images allows visualization of regions adjacent to the heart in which there may be incidental findings that are nonsignificant but in other instances are clinically important. Such incidental findings may cause artifacts and therefore need to be considered when interpreting the perfusion images. These findings may also indicate other cardiovascular conditions and sometimes show important noncardiac pathology. To properly interpret these findings, one must be familiar with normal uptake and kinetics of the cardiac perfusion tracers and have a solid understanding of image acquisition, reconstruction, and processing techniques. Thus, on single-photon emission computed tomography radionuclide myocardial perfusion imaging, raw projection images must be reviewed routinely and systematically for any incidental findings that might affect image interpretation and/or could indicate other disease. Semin Nucl Med 40:257-270 (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:257 / 270
页数:14
相关论文
共 85 条
[1]  
AbdelDayem HM, 1997, J NUCL MED, V38, P1213
[2]  
AKTOLUN C, 1994, EUR J NUCL MED, V21, P973
[3]   CLINICAL-EXPERIENCE WITH TC-99M MIBI IMAGING IN PATIENTS WITH MALIGNANT-TUMORS - PRELIMINARY-RESULTS AND COMPARISON WITH TL-201 [J].
AKTOLUN, C ;
BAYHAN, H ;
KIR, M .
CLINICAL NUCLEAR MEDICINE, 1992, 17 (03) :171-176
[4]  
AKTOLUN C, 1991, J NUCL MED, V32, P1429
[5]   Thyroid imaging with Tc-99m MIBI in patients with solitary cold single nodules on pertechnetate imaging [J].
Alonso, O ;
Lago, G ;
Mut, F ;
Hermida, JC ;
Nunez, M ;
DePalma, G ;
Touya, E .
CLINICAL NUCLEAR MEDICINE, 1996, 21 (05) :363-367
[6]  
ATHAR H, 2008, NUCL CARDIOLOGY TECH
[7]   Attenuation correction single-photon emission computed tomography myocardial perfusion imaging [J].
Bateman, TM ;
Cullom, SJ .
SEMINARS IN NUCLEAR MEDICINE, 2005, 35 (01) :37-51
[8]   Myocardial perfusion imaging agents: SPECT and PET [J].
Beller, GA ;
Bergmann, SR .
JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (01) :71-86
[9]  
Bom HS, 1998, J NUCL MED, V39, P91
[10]   Detection of malignant breast tumours in dense breast tissue:: results of 99mTc-tetrofosmin scintimammography related to surgery [J].
Bongers, V ;
Rinkes, IHMB ;
Sie-Go, DMDS ;
Pijnappel, R ;
de Hooge, P ;
van Rijk, PP .
EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 1999, 25 (02) :152-156