Matrix coating assisted by an electric field (MCAEF) for enhanced tissue imaging by MALDI-MS

被引:42
作者
Wang, Xiaodong [1 ]
Han, Jun [1 ]
Yang, Juncong [1 ]
Pan, Jingxi [1 ]
Borchers, Christoph H. [1 ,2 ]
机构
[1] Univ Victoria, Genome British Columbia Prote Ctr, Victoria, BC V8Z 7X8, Canada
[2] Univ Victoria, Dept Biochem & Microbiol, Victoria, BC V8P 5C2, Canada
关键词
DESORPTION/IONIZATION MASS-SPECTROMETRY; SITU STRUCTURAL-CHARACTERIZATION; IONIC MATRICES; LIPIDS; BRAIN; PROTEINS; PHOSPHOLIPIDS; GLYCEROPHOSPHOLIPIDS; IDENTIFICATION; SUBLIMATION;
D O I
10.1039/c4sc01850h
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel technique, termed matrix coating assisted by an electric field (MCAEF), for enhancing tissue imaging by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was developed in this study. In this technique a static and uniform electric field is applied to sliced tissue sections during matrix spray-coating, resulting in the enrichment of positively or negatively chargeable analytes in the MALDI matrix layer. Experimental results show that MCAEF not only increased the sensitivity of lipid and protein detection across the board in the subsequent MALDI-MS analyses, but also resulted in successful imaging of a larger number of analytes. MALDI imaging enhancement with MCAEF was observed for various tissues (rat liver, rat brain, and porcine adrenal gland) and with different MALDI matrices (e.g., quercetin, 2-mercaptobenzothiazole, dithranol, 9-aminoacridine, and sinapinic acid) and the sensitivity increases were independent of the solvent compositions and pH values of the matrix solutions. Taking rat brain as an example, MCAEF led to the on-tissue detection and imaging of 648 identified lipids by combining positive and negative ion detection by MALDI-Fourier transform ion cyclotron resonance MS and with quercetin as the matrix, as compared to only 344 lipids without MCAEF. For protein imaging, up to 232 protein signals were successfully detected in rat brain tissue sections by MALDI-time-of-flight MS within a mass range of 3500 to 37 000 Da, as compared to 119 without MCAEF. MCAEF also enabled the detection of higher molecular-weight proteins. These results demonstrate the advantages of MCAEF for overall performance improvements in MALDI imaging and we believe that this technique has the potential to become a standard practice for MALDI tissue imaging.
引用
收藏
页码:729 / 738
页数:10
相关论文
共 57 条
[1]   Imaging mass spectrometry of proteins and peptides: 3D volume reconstruction [J].
Andersson, Malin ;
Groseclose, M. Reid ;
Deutch, Ariel Y. ;
Caprioli, Richard M. .
NATURE METHODS, 2008, 5 (01) :101-108
[2]   Enhanced Sensitivity for High Spatial Resolution Lipid Analysis by Negative Ion Mode Matrix Assisted Laser Desorption Ionization Imaging Mass Spectrometry [J].
Angel, Peggi M. ;
Spraggins, Jeffrey M. ;
Baldwin, H. Scott ;
Caprioli, Richard .
ANALYTICAL CHEMISTRY, 2012, 84 (03) :1557-1564
[3]   Profiling and Imaging of Lipids on Brain and Liver Tissue by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Using 2-Mercaptobenzothiazole as a Matrix [J].
Astigarraga, Egoitz ;
Barreda-Gomez, Gabriel ;
Lombardero, Laura ;
Fresnedo, Olatz ;
Castano, Fernando ;
Giralt, Maria Teresa ;
Ochoa, Begona ;
Rodriguez-Puertas, Rafael ;
Fernandez, Jose A. .
ANALYTICAL CHEMISTRY, 2008, 80 (23) :9105-9114
[4]   Automated MALDI matrix deposition method with inkjet printing for imaging mass spectrometry [J].
Baluya, Dodge L. ;
Garrett, Timothy J. ;
Yost, Richard A. .
ANALYTICAL CHEMISTRY, 2007, 79 (17) :6862-6867
[5]   MALDI Imaging of Lipid Biochemistry in Tissues by Mass Spectrometry [J].
Berry, Karin A. Zemski ;
Hankin, Joseph A. ;
Barkley, Robert M. ;
Spraggins, Jeffrey M. ;
Caprioli, Richard M. ;
Murphy, Robert C. .
CHEMICAL REVIEWS, 2011, 111 (10) :6491-6512
[6]   Matrix vapor deposition/recrystallization and dedicated spray preparation for high-resolution scanning microprobe matrix-assisted laser desorption/ionization imaging mass spectrometry (SMALDI-MS) of tissue and single cells [J].
Bouschen, Werner ;
Schulz, Oliver ;
Eikel, Daniel ;
Spengler, Bernhard .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (03) :355-364
[7]   Spatial and temporal alterations of phospholipids determined by mass spectrometry during mouse embryo implantation [J].
Burnum, Kristin E. ;
Cornett, Dale S. ;
Puolitaival, Satu M. ;
Milne, Stephen B. ;
Myers, David S. ;
Tranguch, Susanne ;
Brown, H. Alex ;
Dey, Sudhansu K. ;
Caprioli, Richard M. .
JOURNAL OF LIPID RESEARCH, 2009, 50 (11) :2290-2298
[8]   Proteomic analysis of formalin-fixed paraffin-embedded tissue by MALDI imaging mass spectrometry [J].
Casadonte, Rita ;
Caprioli, Richard M. .
NATURE PROTOCOLS, 2011, 6 (11) :1695-1709
[9]   MALDI Imaging and Structural Analysis of Rat Brain Lipid Negative Ions with 9-Aminoacridine Matrix [J].
Cerruti, Christopher D. ;
Benabdellah, Farida ;
Laprevote, Olivier ;
Touboul, David ;
Brunelle, Alain .
ANALYTICAL CHEMISTRY, 2012, 84 (05) :2164-2171
[10]   Imaging mass spectrometry of intact proteins from alcohol-preserved tissue specimens: Bypassing formalin fixation [J].
Chaurand, Pierre ;
Latham, Joey C. ;
Lane, Kirk B. ;
Mobley, James A. ;
Polosukhin, Vasiliy V. ;
Wirth, Pamela S. ;
Nanney, Lillian B. ;
Caprioli, Richard M. .
JOURNAL OF PROTEOME RESEARCH, 2008, 7 (08) :3543-3555