Economic analysis of data center cooling strategies

被引:42
作者
Cho, Kyuman [1 ]
Chang, Hyunjae [2 ]
Jung, Yongho [3 ]
Yoon, Yoojung [4 ]
机构
[1] Chosun Univ, Sch Architecture, Gwangju, South Korea
[2] Hongik Univ, Sch Architectural Engn, 2639 Sejong Ro, Sejong 339701, South Korea
[3] Chungwoon Univ, Dept Bldg Equipment & Fire Protect Syst, Incheon, South Korea
[4] West Virginia Univ, Dept Civil & Environm Engn, Morgantown, WV USA
关键词
Data center; Data center cooling strategies; Economic analysis; Modular data center; AIR-FLOW; ENERGY-CONSERVATION; OPTIMIZATION; PERFORMANCE; EFFICIENCY; SYSTEMS;
D O I
10.1016/j.scs.2017.03.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Advancements in information technology have led to an increasing demand for data centers (DCs), and the energy consumption of DCs has gained attention worldwide. Many researchers have attempted to develop efficient DC cooling systems to reduce the energy required for cooling DCs, however, there are limitations in identifying the effect of such systems from the economic perspective. Subsequently, project owners find it difficult to decide whether to apply these systems to their particular DCs. The present research aims to analyze the economic performance of seven cooling strategies developed by the combinations of widely used DC cooling systems. The economic performance of each strategy is estimated by the life cycle cost analysis technique, and the analysis results show that Strategy 5 (A2JVI: air -side economizer and supplementary cooling by a mechanical system) yields economic benefits of 26.84% in comparison to the conventional cooling system. The proposed research methodology and obtained results are expected to aid project owners in making effective decisions regarding the selection of an appropriate cooling strategy from an economic perspective. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:234 / 243
页数:10
相关论文
共 30 条
  • [1] ASHRAE, 2009, ASHRAE DAT SER THERM
  • [2] Baek S., 2012, J KOREA FACILITY MAN, V7, P37
  • [3] Evaluation of air distribution system's airflow performance for cooling energy savings in high-density data centers
    Cho, Jinkyun
    Yang, Joonyoung
    Park, Woopyoung
    [J]. ENERGY AND BUILDINGS, 2014, 68 : 270 - 279
  • [4] Assessment of the economic performance of vacuum insulation panels for housing projects
    Cho, Kyuman
    Hong, Yesim
    Seo, Janghoo
    [J]. ENERGY AND BUILDINGS, 2014, 70 : 45 - 51
  • [5] DellIsola A., 2003, LIFE CYCLE COSTING F
  • [6] Data center optimization using PID regulation in CFD simulations
    Durand-Estebe, Baptiste
    Le Bot, Cedric
    Mancos, Jean Nicolas
    Arquis, Eric
    [J]. ENERGY AND BUILDINGS, 2013, 66 : 154 - 164
  • [7] Advances in data center thermal management
    Fulpagare, Yogesh
    Bhargav, Atul
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 43 : 981 - 996
  • [8] Energy saving potential of various air-side economizers in a modular data center
    Ham, Sang-Woo
    Kim, Min-Hwi
    Choi, Byung-Nam
    Jeong, Jae-Weon
    [J]. APPLIED ENERGY, 2015, 138 : 258 - 275
  • [9] Airflow distribution through perforated tiles in raised-floor data centers
    Karki, KC
    Patankar, SV
    [J]. BUILDING AND ENVIRONMENT, 2006, 41 (06) : 734 - 744
  • [10] KICT(Korea Institute of Construction Technology), 2004, STUD DEV LIF CYCL IN