Data-Driven Incipient Fault Detection via Canonical Variate Dissimilarity and Mixed Kernel Principal Component Analysis

被引:45
作者
Wu, Ping [1 ]
Ferrari, Riccardo M. G. [2 ]
Liu, Yichao [2 ]
van Wingerden, Jan-Willem [2 ]
机构
[1] Zhejiang Sci Tech Univ, Dept Automat, Fac Mech Engn & Automat, Hangzhou 310018, Zhejiang, Peoples R China
[2] Delft Univ Technol, Delft Ctr Syst & Control, Fac Mech Maritime & Mat Engn, NL-2628 CD Delft, Netherlands
基金
中国国家自然科学基金;
关键词
Canonical variate analysis (CVA); dissimilarity analysis; incipient fault detection; kernel principal component analysis (KPCA); mixed kernel; DIAGNOSIS; KPCA; PCA; ALGORITHM; SELECTION;
D O I
10.1109/TII.2020.3029900
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Incipient fault detection plays a crucial role in preventing the occurrence of serious faults or failures in industrial processes. In most industrial processes, linear, and nonlinear relationships coexist. To improve fault detection performance, both linear and nonlinear features should be considered simultaneously. In this article, a novel hybrid linear-nonlinear statistical modeling approach for data-driven incipient fault detection is proposed by closely integrating recently developed canonical variate dissimilarity analysis and mixed kernel principal component analysis (MKPCA) using a serial model structure. Specifically, canonical variate analysis (CVA) is first applied to estimate the canonical variables (CVs) from the collected process data. Linear features are extracted from the estimated CVs. Then, the canonical variate dissimilarity (CVD) which quantifies model residuals in the CVA state-subspace is calculated using the estimated CVs. To explore the nonlinear features, the nonlinear principal components are extracted as nonlinear features through performing MKPCA on CVD. Fault detection indices are formed based on Hotelling's T-2 as well as Q statistics from the extracted linear and nonlinear features. Moreover, kernel density estimation is utilized to determine the control limits. The effectiveness of the proposed method is demonstrated by the comparisons with other relevant methods via simulations based on a closed-loop continuous stirred-tank reactor process.
引用
收藏
页码:5380 / 5390
页数:11
相关论文
共 53 条
  • [31] Peters J, 2017, ADAPT COMPUT MACH LE
  • [32] A Review of Kernel Methods for Feature Extraction in Nonlinear Process Monitoring
    Pilario, Karl Ezra
    Shafiee, Mahmood
    Cao, Yi
    Lao, Liyun
    Yang, Shuang-Hua
    [J]. PROCESSES, 2020, 8 (01)
  • [33] Mixed kernel canonical variate dissimilarity analysis for incipient fault monitoring in nonlinear dynamic processes
    Pilario, Karl Ezra S.
    Cao, Yi
    Shafiee, Mahmood
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 2019, 123 : 143 - 154
  • [34] Advances and opportunities in machine learning for process data analytics
    Qin, S. Joe
    Chiang, Leo H.
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 2019, 126 : 465 - 473
  • [35] Canonical variate analysis for performance degradation under faulty conditions
    Ruiz-Carcel, C.
    Lao, L.
    Cao, Y.
    Mba, D.
    [J]. CONTROL ENGINEERING PRACTICE, 2016, 54 : 70 - 80
  • [36] Canonical Variate Dissimilarity Analysis for Process Incipient Fault Detection
    Salgado Pilario, Karl Ezra
    Cao, Yi
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2018, 14 (12) : 5308 - 5315
  • [37] Kernel Canonical Variate Analysis for Nonlinear Dynamic Process Monitoring
    Samuel, Raphael T.
    Cao, Yi
    [J]. IFAC PAPERSONLINE, 2015, 48 (08): : 605 - 610
  • [38] Nonlinear process fault detection and identification using kernel PCA and kernel density estimation
    Samuel, Raphael Tari
    Cao, Yi
    [J]. SYSTEMS SCIENCE & CONTROL ENGINEERING, 2016, 4 (01): : 165 - 174
  • [39] Nonlinear component analysis as a kernel eigenvalue problem
    Scholkopf, B
    Smola, A
    Muller, KR
    [J]. NEURAL COMPUTATION, 1998, 10 (05) : 1299 - 1319
  • [40] Recursive transformed component statistical analysis for incipient fault detection
    Shang, Jun
    Chen, Maoyin
    Ji, Hongquan
    Zhou, Donghua
    [J]. AUTOMATICA, 2017, 80 : 313 - 327