Improving Science by Overcoming Laboratory Pitfalls With Hormone Measurements

被引:15
作者
Hillebrand, Jacquelien J.
Wickenhagen, Wjera, V
Heijboer, Annemieke C.
机构
[1] Vrije Univ Amsterdam, Amsterdam UMC, Amsterdam, Netherlands
[2] Univ Amsterdam, Dept Clin Chem, Endocrine Lab, Amsterdam Gastroenterol Endocrinol & Metab, Amsterdam, Netherlands
关键词
quality; immunoassay; mass spectrometry; matrix; technique; pre-analysis; 25-HYDROXYVITAMIN D ASSAYS; TANDEM MASS-SPECTROMETRY; TESTOSTERONE CONCENTRATIONS; PARATHYROID-HORMONE; HIGH-RESOLUTION; ACCURATE MASS; SERUM; STABILITY; IMMUNOASSAYS; PLASMA;
D O I
10.1210/clinem/dgaa923
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Despite all the effort taken, there is often surprisingly little attention paid to the hormone analyses involved in research studies. Thinking carefully about the quality of the hormone measurements in these studies is, however, of major importance, as this attention to methods may prevent false conclusions and inappropriate follow-up studies. We discuss issues regarding hormone measurements that one should consider, ideally prior to starting, or otherwise, as they arise during a scientific study: quality of the technique, expertise, matrices, timing and storage conditions, freeze-thaw cycles, lot-to-lot and day-to-day variation, analyses per batch or sample-wise, singlicate or duplicate measurements, combining methods, and standardization. This article and the examples mentioned herein aim to clarify the need to pay attention to the hormone analyses, and to help in making decisions. In addition, these examples help editors and reviewers of scientific journals to pay attention to the methods section in the submitted manuscripts and ask the right critical questions when needed.
引用
收藏
页码:E1504 / E1512
页数:9
相关论文
共 78 条
[1]   α-Klotho is unstable in human urine [J].
Adema, Aaltje Y. ;
Vervloet, Marc G. ;
Blankenstein, Marinus A. ;
Heijboer, Annemieke C. .
KIDNEY INTERNATIONAL, 2015, 88 (06) :1442-1444
[2]   Stability of glucagon-like peptide 1 and glucagon in human plasma [J].
Albrechtsen, Nicolai J. Wewer ;
Bak, Monika J. ;
Hartmann, Bolette ;
Christensen, Louise Wulff ;
Kuhre, Rune E. ;
Deacon, Carolyn F. ;
Holst, Jens J. .
ENDOCRINE CONNECTIONS, 2015, 4 (01)
[3]   Failure of Current Laboratory Protocols to Detect Lot-to-Lot Reagent Differences: Findings and Possible Solutions [J].
Algeciras-Schimnich, Alicia ;
Bruns, David E. ;
Boyd, James C. ;
Bryant, Sandra C. ;
La Fortune, Kristin A. ;
Grebe, Stefan K. G. .
CLINICAL CHEMISTRY, 2013, 59 (08) :1187-1194
[4]   FT4 immunoassays may display a pattern during pregnancy similar to the equilibrium dialysis ID-LC/tandem MS candidate reference measurement procedure in spite of susceptibility towards binding protein alterations [J].
Anckaert, Ellen ;
Poppe, Kris ;
Van Uytfanghe, Katleen ;
Schiettecatte, Johan ;
Foulon, Walter ;
Thienpont, Linda M. .
CLINICA CHIMICA ACTA, 2010, 411 (17-18) :1348-1353
[5]  
[Anonymous], ISO 15189:2012
[6]   Vitamin D measurement standardization: The way out of the chaos [J].
Binkley, N. ;
Dawson-Hughes, B. ;
Durazo-Arvizu, R. ;
Thamm, M. ;
Tian, L. ;
Merkel, J. M. ;
Jones, J. C. ;
Carter, G. D. ;
Sempos, C. T. .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2017, 173 :117-121
[7]  
BOLELLI G, 1995, CANCER EPIDEM BIOMAR, V4, P509
[8]   Comparison of eight routine unpublished LC-MS/MS methods for the simultaneous measurement of testosterone and androstenedione in serum [J].
Buttler, Rahel M. ;
Martens, Frans ;
Ackermans, Mariette T. ;
Davison, Andrew S. ;
van Herwaarden, Antonius E. ;
Kortz, Linda ;
Krabbe, Johannes G. ;
Lentjes, Eef G. W. ;
Syme, Charlotte ;
Webster, Rachel ;
Blankenstein, Marinus A. ;
Heijboer, Annemieke C. .
CLINICA CHIMICA ACTA, 2016, 454 :112-118
[9]   Analytical and clinical evaluation of the new Fujirebio Lumipulse® G non-competitive assay for 25(OH)-vitamin D and three immunoassays for 25(OH) D in healthy subjects, osteoporotic patients, third trimester pregnant women, healthy African subjects, hemodialyzed and intensive care patients [J].
Cavalier, Etienne ;
Lukas, Pierre ;
Bekaert, Anne-Catherine ;
Peeters, Stephanie ;
Le Goff, Caroline ;
Yayo, Eric ;
Delanaye, Pierre ;
Souberbielle, Jean-Claude .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (08) :1347-1355
[10]   Analysis of insulin and insulin analogues by mass spectrometry [J].
Couchman, Lewis ;
Taylor, David R. ;
Moniz, Cajetan F. .
ANNALS OF CLINICAL BIOCHEMISTRY, 2016, 53 (02) :302-303