UNCERTAINTY IN CALCULATING AIR EXCHANGE RATE OF NATURALLY VENTILATED DAIRY BUILDING BASED ON POINT CONCENTRATIONS

被引:15
作者
Saha, Chayan K. [1 ,5 ]
Fiedler, Merike [1 ]
Ammon, Christian [1 ]
Berg, Werner [2 ]
Loebsin, Christiane [3 ]
Amon, Barbara [2 ]
Amon, Thomas [1 ,4 ]
机构
[1] Leibniz Inst Agr Engn Potsdam Bornim ATB, Dept Engn Livestock Management, D-14469 Potsdam, Germany
[2] Leibniz Inst Agr Engn Potsdam Bornim ATB, Dept Technol Assessment & Subst Cycles, D-14469 Potsdam, Germany
[3] Inst Anim Prod, State Inst Agr & Fishery MV, D-18196 Dummerstorf, Germany
[4] Free Univ Berlin, Inst Anim Hyg & Environm Hlth, Dept Vet Med, D-10115 Berlin, Germany
[5] Bangladesh Agr Univ, Dept Farm Power & Machinery, Mymensingh 2202, Bangladesh
来源
ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL | 2014年 / 13卷 / 09期
关键词
air exchange rate; air velocity; carbon dioxide; natural ventilation; wind direction; AMMONIA; EMISSIONS; FLOW; MODEL;
D O I
10.30638/eemj.2014.262
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Accurate quantification of gaseous emissions from livestock buildings to the atmosphere requires accurate determination of the ventilation rate and the representative gas concentration in the exhaust air. But there is a lack in the investigation of reasons and uncertainties for selecting sampling points and locations in naturally ventilated dairy (NVD) buildings. The objective of this study was to investigate uncertainties in calculating AER based on carbon dioxide (CO2) balance method. The experiment was carried out in an NVD building located in north-east Germany. Concentrations of CO2 were continuously measured inside the barn at eight uniformly distributed points and outside the barn at four points. Air exchange rate (AER) per hour was calculated using the concentration difference between inside and outside the barn where inside concentrations of 4 sampling locations left (4PL), middle (4PM), right (4PR) and corner (4PC) of the barn, 6 sampling locations in left (6PL), right (6PR) and randomly (6RS) selected points inside the barn were used, then compared with AER calculated using an average CO2 concentration of 8 sampling points (8PA) according to the CO2 balance method. The results showed that the relative AER calculation differences using 4PL, 4PM, 4PR, 4PC, 6PL, 6PR, and 6 RS were -49 to 112%, -5 to 26%, -29 to 34%, -12 to 13%, -5 to 44%, -14 to 10% and -8 to 4% compared to 8PA. The variations in relative differences are because of uncertainties involved in concentration measurement due to the variations of outside wind speed and direction.
引用
收藏
页码:2349 / 2355
页数:7
相关论文
共 19 条
  • [1] [Anonymous], 2001, Third Assessment Report: Climate Change 2001 TAR, DOI DOI 10.1016/S1058-2746(02)86826-4
  • [2] Bell S., 2001, A Beginner's Guide to Uncertainly o f Measurement
  • [3] Critical loads and the relevance of ammonia to an effects-based nitrogen Protocol
    Bull, KR
    Sutton, MA
    [J]. ATMOSPHERIC ENVIRONMENT, 1998, 32 (03) : 565 - 572
  • [4] Ventilation performance prediction for buildings: A method overview and recent applications
    Chen, Qingyan
    [J]. BUILDING AND ENVIRONMENT, 2009, 44 (04) : 848 - 858
  • [5] CIGR, 2002, WORK GROUP REP HEAT
  • [6] SPATIAL DISTRIBUTION OF AIR FLOW AND CO2 CONCENTRATION IN A NATURALLY VENTILATED DAIRY BUILDING
    Fiedler, Merike
    Saha, Chayan K.
    Ammon, Christian
    Berg, Werner
    Loebsin, Christiane
    Sanftleben, Peter
    Amon, Thomas
    [J]. ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2014, 13 (09): : 2193 - 2200
  • [7] Ikeguchi A, 2003, T ASAE, V46, P789, DOI 10.13031/2013.13594
  • [8] Greenhouse gas emissions from animal houses and manure stores
    Jungbluth, T
    Hartung, E
    Brose, G
    [J]. NUTRIENT CYCLING IN AGROECOSYSTEMS, 2001, 60 (1-3) : 133 - 145
  • [9] Multi-location measurements of greenhouse gases and emission rates of methane and ammonia from a naturally-ventilated barn for dairy cows
    Ngwabie, N. M.
    Jeppsson, K. -H.
    Nimmermark, S.
    Swensson, C.
    Gustafsson, G.
    [J]. BIOSYSTEMS ENGINEERING, 2009, 103 (01) : 68 - 77
  • [10] Assessing the ventilation effectiveness of naturally ventilated livestock buildings under wind dominated conditions using computational fluid dynamics
    Norton, Tomas
    Grant, Jim
    Fallon, Richard
    Sun, Da-Wen
    [J]. BIOSYSTEMS ENGINEERING, 2009, 103 (01) : 78 - 99