Design optimization of the solar heating system for office buildings based on life cycle cost in Qinghai-Tibet plateau of China

被引:47
作者
Liu, Yanfeng [1 ,2 ,4 ]
Zhao, Yiting [2 ]
Chen, Yaowen [1 ,2 ,3 ,4 ]
Wang, Dengjia [1 ,2 ]
Li, Yong [1 ,2 ]
Yuan, Xipeng [3 ]
机构
[1] Xian Univ Architecture & Technol, State Key Lab Green Bldg Western China, Xian 710055, Peoples R China
[2] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Peoples R China
[3] Tibet Autonomous Reg Energy Res Demonstrat Ctr, Lhasa 850000, Peoples R China
[4] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, State Key Lab Green Bldg Western China, 13 Yanta Rd, Xian 710055, Peoples R China
基金
中国国家自然科学基金;
关键词
Qinghai-Tibet Plateau; Office buildings; Solar heating system; Optimal capacity ratio; Minimum life cycle cost; MULTIOBJECTIVE OPTIMIZATION; RESIDENTIAL BUILDINGS; AREAS; PUMP;
D O I
10.1016/j.energy.2022.123288
中图分类号
O414.1 [热力学];
学科分类号
摘要
The Qinghai-Tibet Plateau is rich in solar energy resources (SER), and the operation conditions of office buildings are consistent with the daily fluctuations in solar radiation. Solar heating for office buildings on the plateau has great potential. To obtain the optimal capacity ratio of solar heating system (SHS) for office buildings in plateau area, an optimization model of SHS capacity matching was established. The minimum life cycle cost (LCC) was taken as the objective function, and collector area, tank volume and auxiliary heat source (AHS) power as the decision variables in the model. The Qinghai-Tibet plateau was divided into five typical regions, and optimization was carried out for each region. The results show that the system LCC optimized by the intermittent heating load is 12% lower than that calculated by the average intermittent heating load and 44% lower than that calculated by the average parameter method for Lhasa. From an economic perspective, the AHS is suitable for electric boilers or gas boilers in regions with rich or general SER and cold regions with abundant SER. The AHS is suitable for electric boilers, air source heat pumps, or gas boilers in severely cold regions with abundant SER. (c) 2022 Published by Elsevier Ltd.
引用
收藏
页数:16
相关论文
共 38 条
[1]   Dynamic simulation of a solar heating and cooling system for an office building located in Southern Italy [J].
Angrisani, Giovanni ;
Entchev, Evgueniy ;
Roselli, Carlo ;
Sasso, Maurizio ;
Tariello, Francesco ;
Yaici, Wahiba .
APPLIED THERMAL ENGINEERING, 2016, 103 :377-390
[2]  
[Anonymous], TRNSYS TRANS SYST SI
[3]  
[Anonymous], 2019, China Architecture and Architecture
[4]  
[Anonymous], GB501762016
[5]  
[Anonymous], 2012, Design Code for Heating, Ventilation, P5
[6]  
[Anonymous], F CHART SOFTW DEV MA
[7]  
[Anonymous], GBT513662019
[8]   Active solar space heating of residential buildings in northern Hellas - a case study [J].
Argiriou, A ;
Klitsikas, N ;
Balaras, CA ;
Asimakopoulos, DN .
ENERGY AND BUILDINGS, 1997, 26 (02) :215-221
[9]   Analysis of thermal performance of building attached sunspace [J].
Bataineh, Khaled M. ;
Fayez, Nadia .
ENERGY AND BUILDINGS, 2011, 43 (08) :1863-1868
[10]   Experimental and theoretical study on a solar assisted CO2 heat pump for space heating [J].
Chen, J. F. ;
Dai, Y. J. ;
Wang, R. Z. .
RENEWABLE ENERGY, 2016, 89 :295-304