DHPLC is superior to SSCP in screening p53 mutations in esophageal cancer tissues

被引:25
作者
Yamanoshita, O
Kubota, T
Jun, H
Ping, YM
Zhang, XL
Li, XP
Li, SS
Li, XX
Zhu, DC
Fukushima, Y
Nakajima, T
机构
[1] Nagoya Univ, Grad Sch Med, Dept Occupat & Environm Hlth, Showa Ku, Nagoya, Aichi 4668550, Japan
[2] Univ Yamanashi, Interdisciplinary Grad Sch Med & Engn, Fac Med, Dept Environm Hlth & Mol Genet, Yamanashi, Japan
[3] Hebei Med Univ, Affiliated Hosp 4, Dept Thorac Surg, Shijiazhuang, Peoples R China
[4] Hebei Med Univ, Affiliated Hosp 4, Hebei Canc Inst, Shijiazhuang, Peoples R China
[5] Zhang Jia Kou Med Coll, Hebei, Peoples R China
[6] Shinshu Univ, Sch Med, Dept Prevent Med, Nagano, Japan
关键词
p53; mutation detection; denaturing high-performance liquid chromatography; single-strand conformation polymorphism; esophageal cancer;
D O I
10.1002/ijc.20712
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Mutations of the p53 tumor-suppressor gene universally occur on exons 5-8 in human cancer. We analyzed these mutations in esophageal cancer tissue from 207 patients in China using 2 methods, single-strand conformation polymorphism (SSCP), one of the most frequently used methods, and the recently developed denaturing high -performance liquid chromatography (DHPLC), and compared their sensitivity and efficiency. Exons 5-8 of p53 were amplified from esophageal cancer tissue genomes, screened for fragments of mutations and polymorphisms by SSCP and DHPLC in a blind study and confirmed by direct sequencing to detect the mutations and polymorphisms. The numbers detected by DHPLC were greater than those detected by SSCP, though the rate of mutations and polymorphisms was lower in SSCP than in DHPLC, which appeared to detect smaller mutations (substitutions and 1 bp insertions/deletions). Of the mutations with substitutions detected by DHPLC but not by SSCP, 50% substituted adenosine for other nucleotides, suggesting that these mutations are often missed when SSCP is used. According to these data, the sensitivity of SSCP and DHPLC was 81% and 97%, respectively, and the specificity was 97% and 85%, respectively. Our results suggest that DHPLC may be recommended over SSCP when screening gene mutations. Thus, rates of p53 mutations and polymorphisms in esophageal cancer tissue in Chinese patients were 49% and 41% by DHPLC and SSCP, respectively. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 34 条
[1]   CURRENT METHODS OF MUTATION DETECTION [J].
COTTON, RGH .
MUTATION RESEARCH, 1993, 285 (01) :125-144
[2]   Comparison of fluorescent single-strand conformation polymorphism analysis and denaturing high-performance liquid chromatography for detection of EXT1 and EXT2 mutations in hereditary multiple exostoses [J].
Dobson-Stone, C ;
Cox, RD ;
Lonie, L ;
Southam, L ;
Fraser, M ;
Wise, C ;
Bernier, F ;
Hodgson, S ;
Porter, DE ;
Simpson, AHRW ;
Monaco, AP .
EUROPEAN JOURNAL OF HUMAN GENETICS, 2000, 8 (01) :24-32
[3]  
Ellis LA, 2000, HUM MUTAT, V15, P556, DOI 10.1002/1098-1004(200006)15:6<556::AID-HUMU7>3.0.CO
[4]  
2-C
[5]   Denaturing high-performance liquid chromatography is a suitable method for PMM2 mutation screening in carbohydrate-deficient glycoprotein syndrome type IA patients [J].
Erlandson, A ;
Stibler, H ;
Kristiansson, B ;
Wahlström, J ;
Martinsson, T .
GENETIC TESTING, 2000, 4 (03) :293-297
[6]   DNA FRAGMENTS DIFFERING BY SINGLE BASE-PAIR SUBSTITUTIONS ARE SEPARATED IN DENATURING GRADIENT GELS - CORRESPONDENCE WITH MELTING THEORY [J].
FISCHER, SG ;
LERMAN, LS .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1983, 80 (06) :1579-1583
[7]   A comparison of BRCA1 mutation analysis by direct sequencing, SSCP and DHPLC [J].
Gross, E ;
Arnold, N ;
Goette, J ;
Schwarz-Boeger, U ;
Kiechle, M .
HUMAN GENETICS, 1999, 105 (1-2) :72-78
[8]   DHPLC mutation analysis of the hereditary nonpolyposis colon cancer (HNPCC) genes hMLH1 and hMSH2 [J].
Holinski-Feder, E ;
Müller-Koch, Y ;
Friedl, W ;
Moselein, G ;
Keller, G ;
Plaschke, J ;
Ballhausen, W ;
Gross, M ;
Baldwin-Jedele, K ;
Jungck, M ;
Mangold, E ;
Vogelsang, H ;
Schackert, HK ;
Lohse, P ;
Murken, J ;
Meitinger, T .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2001, 47 (1-2) :21-32
[9]   P53 MUTATIONS IN HUMAN CANCERS [J].
HOLLSTEIN, M ;
SIDRANSKY, D ;
VOGELSTEIN, B ;
HARRIS, CC .
SCIENCE, 1991, 253 (5015) :49-53
[10]   CONSTANT DENATURANT GEL-ELECTROPHORESIS, A MODIFICATION OF DENATURING GRADIENT GEL-ELECTROPHORESIS, IN MUTATION DETECTION [J].
HOVIG, E ;
SMITHSORENSEN, B ;
BROGGER, A ;
BORRESEN, AL .
MUTATION RESEARCH, 1991, 262 (01) :63-71