Clinical Usefulness of a Self-Retaining Internal Organ Retractor for Laparoendoscopic Single-Site Adrenalectomy

被引:1
作者
Choo, Seol Ho [1 ]
Lee, Sin Woo [2 ]
Sung, Hyun Hwan [3 ]
Jeong, Byong Chang [3 ]
Han, Deok Hyun [3 ]
机构
[1] Ajou Univ, Sch Med, Dept Urol, Suwon, South Korea
[2] Gyeongsang Natl Univ Hosp, Dept Urol, Jinju, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Urol, 81 Irwon Ro, Seoul 135710, South Korea
来源
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES | 2019年 / 29卷 / 03期
关键词
adrenalectomy; laparoendoscopic single-site surgery; internal organ retractor; CONVENTIONAL LAPAROSCOPIC ADRENALECTOMY; SURGERY; EXPERIENCE; INCISION; OUTCOMES; CHOLECYSTECTOMY; COMPLICATIONS; NEPHRECTOMY; TUMORS;
D O I
10.1089/lap.2018.0414
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Although laparoendoscopic single-site adrenalectomy (LESS-A) is feasible, it is still considered as a challenging procedure because of technical limitations. Making an optimal retraction is one of major obstacles in LESS-A, and it sometimes requires additional ports or needlescopic devices. Internal organ retractor (IOR) is a novel retraction device that is applied intracorporeally without additional port. In this study, we investigated the clinical usefulness of IOR in LESS-A. Materials and Methods: Medical records of 73 consecutive patients who underwent LESS-A from March 2009 to December 2014 were reviewed. Twenty-two patients underwent LESS-A with IOR and 51 patients without IOR. Results: Mean age, body mass index, tumor size, operation time, estimated blood loss, and hospital stay were not significantly different between two groups. In IOR group, median number of applied IOR was 2.0 (1.0-3.0) per single operation. Mean time for application and removal was 80.0 and 46.5 seconds for a single IOR, respectively. There were no complications related to the IOR. In without IOR group, there were nine cases that needed needlescopic trocars, six cases that needed 5 mm or larger trocars, and one case that was converted to hand-assisted laparoscopy. However, we did not use any needlescopic instrument or additional trocar in IOR group. There was no case of open conversion in both groups. Conclusion: LESS-A could be done effectively and safely using IOR. IOR system maintained optimal retraction throughout the operation. Its application and removal are intuitive and take only a few minutes. We think IOR system is an attractive retraction method in LESS-A.
引用
收藏
页码:379 / 384
页数:6
相关论文
共 50 条
  • [41] Laparoendoscopic single-site retroperitoneoscopic adrenalectomy: a matched-pair comparison with the gold standard
    Tao-ping Shi
    Xu Zhang
    Xin Ma
    Hong-zhao Li
    Jie Zhu
    Bao-jun Wang
    Jiang-ping Gao
    Wei Cai
    Juan Dong
    Surgical Endoscopy, 2011, 25 : 2117 - 2124
  • [42] Laparoendoscopic single-site (LESS) retroperitoneal adrenalectomy using a homemade single-access platform and standard laparoscopic instruments
    Shiu-Dong Chung
    Chao-Yuan Huang
    Shuo-Meng Wang
    Huai-Ching Tai
    Yao-Chou Tsai
    Shih-Chieh Chueh
    Surgical Endoscopy, 2011, 25 : 1251 - 1256
  • [43] Laparoendoscopic Single-Site Surgery in Kidney Surgery: Clinical Experience and Future Perspectives
    Kallidonis, Panagiotis
    Kontogiannis, Stavros
    Kyriazis, Iason
    Georgiopoulos, Ioannis
    Al-Aown, Abdulrahman
    Stolzenburg, Jens-Uwe
    Liatsikos, Evangelos
    CURRENT UROLOGY REPORTS, 2013, 14 (05) : 496 - 505
  • [44] Laparoendoscopic Single-Site Surgery in Kidney Surgery: Clinical Experience and Future Perspectives
    Panagiotis Kallidonis
    Stavros Kontogiannis
    Iason Kyriazis
    Ioannis Georgiopoulos
    Abdulrahman Al-Aown
    Jens-Uwe Stolzenburg
    Evangelos Liatsikos
    Current Urology Reports, 2013, 14 : 496 - 505
  • [45] Laparoendoscopic Single-Site Retroperitoneoscopic Adrenalectomy for Pheochromocytoma: Case Selection, Surgical Technique, and Short-Term Outcome
    He, Yao
    Chen, Zhi
    Luo, Yan-Cheng
    Fang, Xiao-Long
    Chen, Xiang
    JOURNAL OF ENDOUROLOGY, 2014, 28 (01) : 56 - 60
  • [46] Effect of preoperative computed tomography parameters and obesity on surgical outcomes of laparoendoscopic single-site adrenalectomy
    Yu-Chen Chen
    Hsiang-Ying Lee
    Ming-Chen Paul Shih
    Yung-Shun Juan
    Hao-Wei Chen
    Wen-Jeng Wu
    Yu-Tsang Wang
    Ching-Chia Li
    Surgical Endoscopy, 2020, 34 : 4781 - 4787
  • [47] Early experience with isobaric laparoendoscopic single-site surgery using a wound retractor for the management of ectopic pregnancy
    Takeda, Akihiro
    Imoto, Sanae
    Mori, Masahiko
    Nakano, Tomoko
    Nakamura, Hiromi
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2011, 154 (02) : 209 - 214
  • [48] Effect of preoperative computed tomography parameters and obesity on surgical outcomes of laparoendoscopic single-site adrenalectomy
    Chen, Yu-Chen
    Lee, Hsiang-Ying
    Shih, Ming-Chen Paul
    Juan, Yung-Shun
    Chen, Hao-Wei
    Wu, Wen-Jeng
    Wang, Yu-Tsang
    Li, Ching-Chia
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2020, 34 (11): : 4781 - 4787
  • [49] Laparoendoscopic single-site adrenalectomy versus conventional laparoscopic adrenalectomy: a comparison of surgical outcomes and an analysis of a single surgeon’s learning curve
    Yosuke Hirasawa
    Akira Miyajima
    Seiya Hattori
    Kazutoshi Miyashita
    Isao Kurihara
    Hirotaka Shibata
    Eiji Kikuchi
    Ken Nakagawa
    Mototsugu Oya
    Surgical Endoscopy, 2014, 28 : 2911 - 2919
  • [50] Clinical evaluation of a novel commercial single port in laparoendoscopic single-site surgery
    Liu, Ying-Buh
    Chen, Jing-Liang
    Chao, Che-Yi
    Tsai, Yao-Chou
    UROLOGICAL SCIENCE, 2015, 26 (02) : 85 - 89