Clinical Usefulness of a Self-Retaining Internal Organ Retractor for Laparoendoscopic Single-Site Adrenalectomy

被引:1
作者
Choo, Seol Ho [1 ]
Lee, Sin Woo [2 ]
Sung, Hyun Hwan [3 ]
Jeong, Byong Chang [3 ]
Han, Deok Hyun [3 ]
机构
[1] Ajou Univ, Sch Med, Dept Urol, Suwon, South Korea
[2] Gyeongsang Natl Univ Hosp, Dept Urol, Jinju, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Urol, 81 Irwon Ro, Seoul 135710, South Korea
来源
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES | 2019年 / 29卷 / 03期
关键词
adrenalectomy; laparoendoscopic single-site surgery; internal organ retractor; CONVENTIONAL LAPAROSCOPIC ADRENALECTOMY; SURGERY; EXPERIENCE; INCISION; OUTCOMES; CHOLECYSTECTOMY; COMPLICATIONS; NEPHRECTOMY; TUMORS;
D O I
10.1089/lap.2018.0414
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Although laparoendoscopic single-site adrenalectomy (LESS-A) is feasible, it is still considered as a challenging procedure because of technical limitations. Making an optimal retraction is one of major obstacles in LESS-A, and it sometimes requires additional ports or needlescopic devices. Internal organ retractor (IOR) is a novel retraction device that is applied intracorporeally without additional port. In this study, we investigated the clinical usefulness of IOR in LESS-A. Materials and Methods: Medical records of 73 consecutive patients who underwent LESS-A from March 2009 to December 2014 were reviewed. Twenty-two patients underwent LESS-A with IOR and 51 patients without IOR. Results: Mean age, body mass index, tumor size, operation time, estimated blood loss, and hospital stay were not significantly different between two groups. In IOR group, median number of applied IOR was 2.0 (1.0-3.0) per single operation. Mean time for application and removal was 80.0 and 46.5 seconds for a single IOR, respectively. There were no complications related to the IOR. In without IOR group, there were nine cases that needed needlescopic trocars, six cases that needed 5 mm or larger trocars, and one case that was converted to hand-assisted laparoscopy. However, we did not use any needlescopic instrument or additional trocar in IOR group. There was no case of open conversion in both groups. Conclusion: LESS-A could be done effectively and safely using IOR. IOR system maintained optimal retraction throughout the operation. Its application and removal are intuitive and take only a few minutes. We think IOR system is an attractive retraction method in LESS-A.
引用
收藏
页码:379 / 384
页数:6
相关论文
共 50 条
  • [1] Initial Experiences of a Novel Self-Retaining Intracorporeal Retractor Device for Urologic Laparoendoscopic Single-Site Surgery
    Choo, Seol Ho
    Jung, Wonho
    Jeong, Useok
    Jeong, Byong Chang
    Han, Deok Hyun
    JOURNAL OF ENDOUROLOGY, 2014, 28 (04) : 404 - 409
  • [2] Laparoendoscopic single-site retroperitoneoscopic adrenalectomy: a matched-pair comparison with the gold standard
    Shi, Tao-ping
    Zhang, Xu
    Ma, Xin
    Li, Hong-zhao
    Zhu, Jie
    Wang, Bao-jun
    Gao, Jiang-ping
    Cai, Wei
    Dong, Juan
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (07): : 2117 - 2124
  • [3] Technical difficulties of transumbilical laparoendoscopic single-site adrenalectomy: comparison with conventional laparoscopic adrenalectomy
    Ishida, Masaru
    Miyajima, Akira
    Takeda, Toshikazu
    Hasegawa, Masanori
    Kikuchi, Eiji
    Oya, Mototsugu
    WORLD JOURNAL OF UROLOGY, 2013, 31 (01) : 199 - 203
  • [4] The learning curve of laparoendoscopic single-site adrenalectomy: an analysis of over 100 cases
    Fukumoto, Keishiro
    Miyajima, Akira
    Hattori, Seiya
    Matsumoto, Kazuhiro
    Abe, Takayuki
    Kurihara, Isao
    Jinzaki, Masahiro
    Kikuchi, Eiji
    Oya, Mototsugu
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2017, 31 (01): : 170 - 177
  • [5] Laparoendoscopic Single-site Adrenalectomy versus Conventional Laparoscopic Adrenalectomy: An Updated Meta Analysis
    Wu, Shike
    Lai, Hao
    Zhao, Jiangyang
    Chen, Jiansi
    Mo, Xianwei
    Zuo, Hongqun
    Lin, Yuan
    UROLOGY JOURNAL, 2016, 13 (02) : 2590 - 2598
  • [6] Comparison of Laparoendoscopic Single-Site Adrenalectomy with the Aid of Intracavitary Retractors and Multiport Laparoendoscopic Adrenalectomy
    Liu, Wei
    Hu, Haibin
    Liu, Fuyang
    Wei, Yong
    Jiang, Rongjiang
    Shen, Luming
    Zhu, Qingyi
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2024, 34 (12): : 1088 - 1093
  • [7] Needlescopic-assisted laparoendoscopic single-site adrenalectomy
    Inoue, Shogo
    Kajiwara, Mitsuru
    Teishima, Jun
    Matsubara, Akio
    ASIAN JOURNAL OF SURGERY, 2016, 39 (01) : 6 - 11
  • [8] Synchronous Bilateral Laparoendoscopic Single-Site Adrenalectomy
    Jeong, Chang Wook
    Park, Yong Hyun
    Shin, Chan Soo
    Kim, Hyeon Hoe
    JOURNAL OF ENDOUROLOGY, 2010, 24 (08) : 1301 - 1305
  • [9] Laparoendoscopic single-site surgery adrenalectomy - own experience and matched case-control study with standard laparoscopic adrenalectomy
    Hora, Milan
    Urge, Tomas
    Stransky, Petr
    Travnicek, Ivan
    Pitra, Tomas
    Kalusova, Kristyna
    Dolejsova, Olga
    Petersson, Fredrik
    Krcma, Michal
    Chlosta, Piotr
    VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES, 2014, 9 (04) : 596 - 602
  • [10] Technical difficulties of transumbilical laparoendoscopic single-site adrenalectomy: comparison with conventional laparoscopic adrenalectomy
    Masaru Ishida
    Akira Miyajima
    Toshikazu Takeda
    Masanori Hasegawa
    Eiji Kikuchi
    Mototsugu Oya
    World Journal of Urology, 2013, 31 : 199 - 203