Discrete ejector control solution design, characterization, and verification in a 5 kW PEMFC system

被引:67
作者
Nikiforow, K. [1 ]
Koski, P. [1 ]
Ihonen, J. [1 ]
机构
[1] VTT Tech Res Ctr Finland, POB 1000, Espoo 02044, Finland
基金
芬兰科学院;
关键词
PEMFC; Anode gas recirculation; Ejector; Ejector control; Inert build-up; Power ramp-up; FUEL-CELL SYSTEM; VACUUM EJECTOR; RECIRCULATION; ANODE; FLOW; OPTIMIZATION; PARAMETERS; OPERATION; NITROGEN; PURGE;
D O I
10.1016/j.ijhydene.2017.05.151
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
An ejector primary gas flow control solution based on three solenoid valves is designed, implemented and tested in a 5 kW proton exchange membrane fuel cell (PEMFC) system with ejector-based anode gas recirculation. The robust and cost effective combination of the tested flow control method and a single ejector is shown to achieve adequate anode gas recirculation rate on a wide PEMFC load range. In addition, the effect of anode gas inert content on ejector performance in the 5 kW PEMFC system is studied at varying load and anode pressure levels. Results show that increasing the inert content increases recirculated anode gas mass flow rate but decreases both the molar flow rate and the anode inlet humidity. Finally, the PEMFC power ramp-rate limitations are studied using two fuel supply strategies: 1) advancing fuel supply and venting out extra fuel and 2) not advancing fuel supply but instead using a large anode volume. Results indicate that the power of the present PEMFC system can be ramped from 1 kW to 4.2 kW within few hundred milliseconds using either of these strategies. (C) 2017 The Authors. Published by Elsevier Ltd on behalf of Hydrogen Energy Publications LLC.
引用
收藏
页码:16760 / 16772
页数:13
相关论文
共 27 条
[1]   High Potential Excursions during PEM Fuel Cell Operation with Dead-Ended Anode [J].
Abbou, S. ;
Dillet, J. ;
Spernjak, D. ;
Mukundan, R. ;
Borup, R. L. ;
Maranzana, G. ;
Lottin, O. .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2015, 162 (10) :F1212-F1220
[2]   Buildup of nitrogen in direct hydrogen polymer-electrolyte fuel cell stacks [J].
Ahluwalia, R. K. ;
Wang, X. .
JOURNAL OF POWER SOURCES, 2007, 171 (01) :63-71
[3]   Modeling and control of air stream and hydrogen flow with recirculation in a PEM fuel cell system - I. Control-oriented modeling [J].
Bao, Cheng ;
Ouyang, Minggao ;
Yi, Baolian .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2006, 31 (13) :1879-1896
[4]   Design and characterization of an electronically controlled variable flow rate ejector for fuel cell applications [J].
Brunner, Douglas A. ;
Marcks, Shane ;
Bajpai, Manish ;
Prasad, Ajay K. ;
Advani, Suresh G. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2012, 37 (05) :4457-4466
[5]   Analysis of design parameters in anodic recirculation system based on ejector technology for PEM fuel cells: A new approach in designing [J].
Dadvar, Mohsen ;
Afshari, Ebrahim .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (23) :12061-12073
[6]   Impact of flow rates and electrode specifications on degradations during repeated startups and shutdowns in polymer-electrolyte membrane fuel cells [J].
Dillet, J. ;
Spernjak, D. ;
Lamibrac, A. ;
Maranzana, G. ;
Mukundan, R. ;
Fairweather, J. ;
Didierjean, S. ;
Borup, R. L. ;
Lottin, O. .
JOURNAL OF POWER SOURCES, 2014, 250 :68-79
[7]   Analysis and control of a fuel delivery system considering a two-phase anode model of the polymer electrolyte membrane fuel cell stack [J].
He, Jinglin ;
Ahn, Jongwoo ;
Choe, Song-Yul .
JOURNAL OF POWER SOURCES, 2011, 196 (10) :4655-4670
[8]   Numerical analysis of transport phenomena for designing of ejector in PEM forklift system [J].
Hosseinzadeh, Elham ;
Rokni, Masoud ;
Jabbari, Masoud ;
Mortensen, Henrik .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (12) :6664-6674
[9]   Numerical and experimental investigation into passive hydrogen recovery scheme using vacuum ejector [J].
Hwang, Jenn-Jiang ;
Cho, Ching-Chang ;
Wu, Wei ;
Chiu, Ching-Huang ;
Chiu, Kuo-Ching ;
Lin, Chih-Hong .
JOURNAL OF POWER SOURCES, 2015, 275 :539-546
[10]   Passive hydrogen recovery schemes using a vacuum ejector in a proton exchange membrane fuel cell system [J].
Hwang, Jenn-Jiang .
JOURNAL OF POWER SOURCES, 2014, 247 :256-263